Furnace, Heat Pump & A2L Fault Code Reference
Look up residential gas furnace, heat pump, and A2L RDS control board LED blink patterns with safe homeowner inspection steps and licensed technician manometer/microamp protocols. Furnace, Heat Pump & A2L Fault Code Reference benchmarks residential systems using Federal AC Minimum set at 13.4 - 14.3 SEER2 and Cleaner Refrigerants set at R-454B or R-32.
- Federal AC Minimum
- 13.4 - 14.3 SEER2
- Cleaner Refrigerants
- R-454B or R-32
- Federal 25C Credit
- Ended Dec 31, 2025
- Covered Homes
- Single-Family & Townhomes
Which individual reference pages are available under Furnace, Heat Pump & A2L Fault Code Reference?
Select any of the 126 verified listings below to open detailed specifications, safety boundaries, and source links.
Code 31: Pressure Switch Did Not Close or Reopened
Code 33: Limit Circuit Fault (High-Temp Cutoff)
Code 34: Ignition Proving Failure (Flame Sense)
Code E5: Open Fuse or Primary Limit Circuit Open
Code EE / E0: Ignition Lockout or Flame Sense Fault
Trane 3 Flashes: Pressure Switch Open With Inducer Running
Rheem / Ruud Code 57: Pressure Switch Stuck Open
Mitsubishi Code P6 / U1: Freezing or Overheating Protection
A2L RDS Mitigation Active: Refrigerant Leak Sensor Triggered
Carrier / Bryant / Payne 11: No Previous Fault Stored in Memory
Carrier / Bryant / Payne 12: Blower On After Power-Up (90-Sec Purge)
Carrier / Bryant / Payne 13: Limit Circuit Lockout (3-Hour Thermal Hold)
Carrier / Bryant / Payne 14: Ignition Lockout (4 Missed Trials)
Carrier / Bryant / Payne 21: Gas Heating Lockout (Valve Relay Fault)
Carrier / Bryant / Payne 22: Abnormal Flame-Proving Signal
Carrier / Bryant / Payne 23: Pressure Switch Did Not Open Before Purge
Secondary 24VAC Fuse Open (3A / 5A)
Carrier / Bryant / Payne 32: Low-Stage Pressure Switch Did Not Close
Carrier / Bryant / Payne 41: Indoor Blower Motor RPM / Feedback Fault
Carrier / Bryant / Payne 42: Inducer Motor RPM / Hall Sensor Fault
Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed
Carrier / Bryant / Payne 45: Control Board Hardware Self-Check Lockout
Trane / American Standard 2-FLASH: External Ignition Lockout (Retries Exhausted)
Trane / American Standard 4-FLASH: Open High-Temperature Limit Circuit
Trane / American Standard 5-FLASH: Flame Sensed When Gas Valve Off
Trane / American Standard 6-FLASH: 115VAC Hot/Neutral Polarity or Ground Fault
Trane / American Standard 7-FLASH: Gas Valve Circuit Error (Open/Shorted)
Trane / American Standard 8-FLASH: Weak Flame Sense Signal (Microamp Warning)
Trane / American Standard 9-FLASH: Open Igniter or Inducer Feedback Fault
Trane / American Standard E1: Trane ComfortLink / TAM Air Handler Airflow Fault
Trane / American Standard E2: Outdoor Ambient Thermistor Out of Range
Trane / American Standard E3: Outdoor Coil Temperature Sensor Fault
Trane / American Standard E4: High-Pressure Cutout Switch Tripped
Trane / American Standard E7: Low-Pressure Suction Cutout Tripped
Trane / American Standard E8: ComfortLink / Communicating Data Bus Loss
Lennox Code 113: High AC Line Voltage
Lennox Code 204: Gas Valve Check Fault
Lennox Code 240: Low Flame Sense Current
Lennox Code 273: Flame Lost Mid-Cycle
Goodman Code E0: Ignition Lockout (Retries Exhausted)
Goodman Code E1: Weak Flame Rectification Signal
Goodman Code E2: Pressure Switch Stuck Open
Goodman Code E3: Pressure Switch Stuck Closed
Goodman Code E4: Open Rollout or Auxiliary Limit
Goodman Code E6: Flame Sensed With Gas Valve Off
Goodman Code E7: Igniter Fault / Open Circuit
Goodman Code E8: Primary High-Limit Tripped
Goodman Code E9: Reversed 115V Polarity / No Ground
Goodman Code EA: Gas Valve Relay Circuit Fault
Goodman Code EC: ComfortNet / Communicating Fault
Goodman / Daikin Code b0: Blower Motor Not Running
Goodman / Daikin Code b1: Blower Communication Error
Goodman / Daikin Code b3: Blower High Static / Power Limit
Goodman / Daikin Code b5: Blower Locked Rotor Fault
Goodman / Daikin Code d0: No Network Data on Bus
Rheem / Ruud Code 10: One-Hour Ignition Lockout
Rheem / Ruud Code 11: Failed Ignition Trial
Rheem / Ruud Code 12: Low Flame Signal Warning
Rheem / Ruud Code 13: Flame Lost After Ignition
Rheem / Ruud Code 14: Flame Sensed Without Gas Call
Rheem / Ruud Code 20: Gas Valve Circuit Fault
Rheem / Ruud Code 22: Main High-Limit Switch Open
Rheem / Ruud Code 26: Line Voltage Polarity / Ground Fault
Rheem / Ruud Code 30: Blower Motor Comm / Fault
Rheem / Ruud Code 33: Limit Switch Lockout (Repeated Trips)
Rheem / Ruud Code 44: Low-Fire Pressure Switch Open
Rheem / Ruud Code 45: Low-Fire Pressure Switch Closed
Rheem / Ruud Code 55: High-Fire Pressure Switch Closed
Rheem / Ruud Code 58: Condensate Water Sensor Triggered
Rheem / Ruud Code 59: Condensate Sensor Lockout
Rheem / Ruud Code 61: Inducer Motor Comm / Speed Fault
Rheem / Ruud Code 66: A2L Refrigerant Mitigation
York / Coleman / Luxaire 1-FLASH: York / Coleman 1 Flash: Flame Failed (Retry)
York / Coleman / Luxaire 2-FLASH: York / Coleman 2 Flashes: Pressure Switch Stuck Closed
York / Coleman / Luxaire 3-FLASH: York / Coleman 3 Flashes: Pressure Switch Stuck Open
York / Coleman / Luxaire 5-FLASH: York / Coleman 5 Flashes: Flame Sensed Without Call
York / Coleman / Luxaire 6-FLASH: York / Coleman 6 Flashes: 1-Hour Ignition Lockout
York / Coleman / Luxaire 7-FLASH: York / Coleman 7 Flashes: Ignition Retry Limit
York / Coleman / Luxaire 8-FLASH: York / Coleman 8 Flashes: Repeated Flame Loss
York / Coleman / Luxaire 9-FLASH: York / Coleman 9 Flashes: Reversed Polarity / Ground
York / Coleman / Luxaire 10-FLASH: York / Coleman 10 Flashes: Gas Valve Circuit Fault
York / Coleman / Luxaire RED-SOLID: York / Coleman Solid Red LED: Board Fault / Rollout
York / Coleman / Luxaire RAPID-AMBER: York / Coleman Rapid Amber: Weak Flame Current
Mitsubishi Code P1: Intake Air Thermistor Error
Mitsubishi Code P2: Liquid Pipe Thermistor Error
Mitsubishi Code P4: Condensate Drain Sensor Open
Mitsubishi Code P5: Condensate Drain Pump Overflow
Mitsubishi Code P8: Pipe Temperature Abnormality
Mitsubishi Code P9: Two-Phase Pipe Thermistor Error
Mitsubishi Code U1: High Pressure Switch Trip
Mitsubishi Code U2: High Compressor Discharge Temp
Mitsubishi Code U3: Discharge Thermistor Open/Short
Mitsubishi Code U4: Outdoor Defrost/Ambient Sensor
Mitsubishi Code E6: Indoor-to-Outdoor Serial Comm Error
Mitsubishi Code E7: Serial Transmission Reception Error
Mitsubishi Code E9: Indoor-Outdoor Transmit Timeout
Nest Code N72: Power Wire Rh/Rc Not Detected
Nest Code N73: No Power Detected on Rc Wire
Nest Code N74: No Power Detected on Rh Wire
Nest Code N260: C-Wire or Power Connector Needed
Nest Code E73: No Power to Rc Wire
Nest Code E74: No Power to Rh Wire
Nest Code E79: No Power / Common C-Wire Fault
Nest Code E80: No Power on Y1 Cooling Wire
Nest Code E103: Overcurrent on Y1 Cooling Wire
Nest Code E195: Power Cut to R Wire
ecobee AUX-ALERT: ecobee Alert: Auxiliary Heat Running Too Long
ecobee COOL-FAIL: ecobee Alert: Cooling Failed to Reach Setpoint
ecobee HEAT-FAIL: ecobee Alert: Heating Failed to Reach Setpoint
ecobee PEK-FAULT: ecobee Power Extender Kit (PEK) Wiring Alert
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
What primary metric defines Furnace, Heat Pump & A2L Fault Code Reference?
Furnace, Heat Pump & A2L Fault Code Reference anchors on Federal AC Minimum at 13.4 - 14.3 SEER2 and Cleaner Refrigerants at R-454B or R-32, sourced from federal datasets and OEM filings.
How are Federal 25C Credit figures verified for Furnace, Heat Pump & A2L Fault Code Reference?
Federal 25C Credit: Ended Dec 31, 2025 and Covered Homes: Single-Family & Townhomes inside Furnace, Heat Pump & A2L Fault Code Reference derive directly from public government data with zero paid boosts.
Who falls outside Furnace, Heat Pump & A2L Fault Code Reference applicability?
Furnace, Heat Pump & A2L Fault Code Reference addresses single-family and townhome systems only; commercial systems and permit sizing need local engineering review.
How do federal regional rules govern Furnace, Heat Pump & A2L Fault Code Reference?
Regional efficiency rules enforce 13.4 North and 14.3 South SEER2 minimums around Furnace, Heat Pump & A2L Fault Code Reference.
Does the under-700 GWP rule affect Furnace, Heat Pump & A2L Fault Code Reference?
2026 residential split equipment covered under Furnace, Heat Pump & A2L Fault Code Reference transitions to R-454B or R-32 with UL 60335-2-40 sensors.
Are 2026 federal tax credits active on Furnace, Heat Pump & A2L Fault Code Reference?
IRS 25C ended Dec 31, 2025 under Public Law 119-21 ($0 in 2026); consult state HEAR programs alongside Furnace, Heat Pump & A2L Fault Code Reference.
What technician license applies to Furnace, Heat Pump & A2L Fault Code Reference work?
Pressurized refrigerant lines and 240V controls noted in Furnace, Heat Pump & A2L Fault Code Reference mandate EPA Section 608 and state mechanical licensing.
How can owners cross-check quotes on Furnace, Heat Pump & A2L Fault Code Reference?
Confirm AHRI reference numbers, <=0.50 in. w.c. static pressure limits, and active board registration when reviewing Furnace, Heat Pump & A2L Fault Code Reference.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
- Goodman / Daikin / Amana Residential Literature Library — Daikin Comfort Technologies, Goodman Public Library (retrieved 2026-11-23)
- Trane / American Standard Residential HVAC Literature & Fault Reference — Trane Technologies (Public Docs), Trane LitWeb Public (retrieved 2026-11-23)
- Lennox Residential Public Product & Warranty Documentation — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
- Mitsubishi Electric Trane HVAC US MyLinkDrive Service & Fault Manuals — Mitsubishi Electric Trane HVAC US, MyLinkDrive Public (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 2 pages.