Furnace, Heat Pump & A2L Fault Code Reference

Look up residential gas furnace, heat pump, and A2L RDS control board LED blink patterns with safe homeowner inspection steps and licensed technician manometer/microamp protocols. Furnace, Heat Pump & A2L Fault Code Reference benchmarks residential systems using Federal AC Minimum set at 13.4 - 14.3 SEER2 and Cleaner Refrigerants set at R-454B or R-32.

Federal AC Minimum
13.4 - 14.3 SEER2
Cleaner Refrigerants
R-454B or R-32
Federal 25C Credit
Ended Dec 31, 2025
Covered Homes
Single-Family & Townhomes
HVAC furnace control board with glowing amber and green diagnostic status LEDs
Furnace, Heat Pump & A2L Fault Code Reference editorial reference. ThermalSpec Editorial Photography

Which individual reference pages are available under Furnace, Heat Pump & A2L Fault Code Reference?

Select any of the 126 verified listings below to open detailed specifications, safety boundaries, and source links.

Carrier / Bryant / Payne31

Code 31: Pressure Switch Did Not Close or Reopened

3 slow amber flashes followed by 1 fast amber flash

Carrier / Bryant / Payne33

Code 33: Limit Circuit Fault (High-Temp Cutoff)

3 slow amber flashes followed by 3 fast amber flashes

Carrier / Bryant / Payne34

Code 34: Ignition Proving Failure (Flame Sense)

3 slow amber flashes followed by 4 fast amber flashes

Goodman / Daikin / AmanaE5

Code E5: Open Fuse or Primary Limit Circuit Open

5 LED flashes or 7-segment display showing E5 / E0

Goodman / Daikin / AmanaEE

Code EE / E0: Ignition Lockout or Flame Sense Fault

7-segment display EE / E0 or 1-flash soft lockout

Lennox154

Lennox Code 154 / E250: Primary Limit Open or Airflow Fault

7-segment LED diagnostic display code or alternating amber/green flash

Trane / American Standard3-FLASH

Trane 3 Flashes: Pressure Switch Open With Inducer Running

3 continuous red flashes on Integrated Furnace Control (IFC)

Rheem / Ruud57

Rheem / Ruud Code 57: Pressure Switch Stuck Open

Dual 7-segment display showing 57 (or 2-digit status readout)

Mitsubishi ElectricP6

Mitsubishi Code P6 / U1: Freezing or Overheating Protection

6 indoor LED flashes or P6/U1 wired controller code

Carrier / Bryant / PayneA2L-RDS

A2L RDS Mitigation Active: Refrigerant Leak Sensor Triggered

Continuous indoor blower run with compressor lockout on RDS mitigation board

Carrier / Bryant / Payne11

Carrier / Bryant / Payne 11: No Previous Fault Stored in Memory

1 slow amber flash followed by 1 fast amber flash

Carrier / Bryant / Payne12

Carrier / Bryant / Payne 12: Blower On After Power-Up (90-Sec Purge)

1 slow amber flash followed by 2 fast amber flashes

Carrier / Bryant / Payne13

Carrier / Bryant / Payne 13: Limit Circuit Lockout (3-Hour Thermal Hold)

1 slow amber flash followed by 3 fast amber flashes

Carrier / Bryant / Payne14

Carrier / Bryant / Payne 14: Ignition Lockout (4 Missed Trials)

1 slow amber flash followed by 4 fast amber flashes

Carrier / Bryant / Payne21

Carrier / Bryant / Payne 21: Gas Heating Lockout (Valve Relay Fault)

2 slow amber flashes followed by 1 fast amber flash

Carrier / Bryant / Payne22

Carrier / Bryant / Payne 22: Abnormal Flame-Proving Signal

2 slow amber flashes followed by 2 fast amber flashes

Carrier / Bryant / Payne23

Carrier / Bryant / Payne 23: Pressure Switch Did Not Open Before Purge

2 slow amber flashes followed by 3 fast amber flashes

Carrier / Bryant / Payne24

Secondary 24VAC Fuse Open (3A / 5A)

2 slow amber flashes followed by 4 fast amber flashes

Carrier / Bryant / Payne32

Carrier / Bryant / Payne 32: Low-Stage Pressure Switch Did Not Close

3 slow amber flashes followed by 2 fast amber flashes

Carrier / Bryant / Payne41

Carrier / Bryant / Payne 41: Indoor Blower Motor RPM / Feedback Fault

4 slow amber flashes followed by 1 fast amber flash

Carrier / Bryant / Payne42

Carrier / Bryant / Payne 42: Inducer Motor RPM / Hall Sensor Fault

4 slow amber flashes followed by 2 fast amber flashes

Carrier / Bryant / Payne43

Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed

4 slow amber flashes followed by 3 fast amber flashes

Carrier / Bryant / Payne45

Carrier / Bryant / Payne 45: Control Board Hardware Self-Check Lockout

4 slow amber flashes followed by 5 fast amber flashes

Trane / American Standard2-FLASH

Trane / American Standard 2-FLASH: External Ignition Lockout (Retries Exhausted)

2 continuous red flashes on IFC LED

Trane / American Standard4-FLASH

Trane / American Standard 4-FLASH: Open High-Temperature Limit Circuit

4 continuous red flashes on IFC LED

Trane / American Standard5-FLASH

Trane / American Standard 5-FLASH: Flame Sensed When Gas Valve Off

5 continuous red flashes on IFC LED

Trane / American Standard6-FLASH

Trane / American Standard 6-FLASH: 115VAC Hot/Neutral Polarity or Ground Fault

6 continuous red flashes on IFC LED

Trane / American Standard7-FLASH

Trane / American Standard 7-FLASH: Gas Valve Circuit Error (Open/Shorted)

7 continuous red flashes on IFC LED

Trane / American Standard8-FLASH

Trane / American Standard 8-FLASH: Weak Flame Sense Signal (Microamp Warning)

8 continuous red flashes on IFC LED

Trane / American Standard9-FLASH

Trane / American Standard 9-FLASH: Open Igniter or Inducer Feedback Fault

9 continuous red flashes on IFC LED

Trane / American StandardE1

Trane / American Standard E1: Trane ComfortLink / TAM Air Handler Airflow Fault

7-segment display alternating E1

Trane / American StandardE2

Trane / American Standard E2: Outdoor Ambient Thermistor Out of Range

7-segment display showing E2

Trane / American StandardE3

Trane / American Standard E3: Outdoor Coil Temperature Sensor Fault

7-segment display showing E3

Trane / American StandardE4

Trane / American Standard E4: High-Pressure Cutout Switch Tripped

7-segment display showing E4

Trane / American StandardE7

Trane / American Standard E7: Low-Pressure Suction Cutout Tripped

7-segment display showing E7

Trane / American StandardE8

Trane / American Standard E8: ComfortLink / Communicating Data Bus Loss

7-segment display showing E8

Lennox110

Lennox Code 110: Low AC Line Voltage (< 90VAC)

7-segment LED showing 110

Lennox113

Lennox Code 113: High AC Line Voltage

7-segment LED showing 113

Lennox114

Lennox Code 114: Line Polarity Reversed / Ground Missing

7-segment LED showing 114

Lennox201

Lennox Code 201: Indoor Blower Communication Lost

7-segment LED showing 201

Lennox202

Lennox Code 202: Blower Motor Speed / Over-Current

7-segment LED showing 202

Lennox204

Lennox Code 204: Gas Valve Check Fault

7-segment LED showing 204

Lennox224

Lennox Code 224: Low-Fire Pressure Switch Open

7-segment LED showing 224

Lennox240

Lennox Code 240: Low Flame Sense Current

7-segment LED showing 240

Lennox241

Lennox Code 241: Flame Sensed Without Heat Call

7-segment LED showing 241

Lennox250

Lennox Code 250: Primary High-Limit Switch Open

7-segment LED showing 250

Lennox270

Lennox Code 270: Flame Failed to Prove (Soft Lockout)

7-segment LED showing 270

Lennox272

Lennox Code 272: Pressure Switch Opened During Run

7-segment LED showing 272

Lennox273

Lennox Code 273: Flame Lost Mid-Cycle

7-segment LED showing 273

Lennox290

Lennox Code 290: Igniter Relay / Circuit Open

7-segment LED showing 290

Lennox310

Lennox Code 310: Rollout Switch Open (Manual Reset)

7-segment LED showing 310

Lennox311

Lennox Code 311: High-Stage Pressure Switch Open

7-segment LED showing 311

Lennox400

Lennox Code 400: A2L Refrigerant Sensor Mitigation

7-segment LED showing 400 / blower forced ON

Goodman / Daikin / AmanaE0

Goodman Code E0: Ignition Lockout (Retries Exhausted)

7-segment display showing E0

Goodman / Daikin / AmanaE1

Goodman Code E1: Weak Flame Rectification Signal

7-segment display showing E1

Goodman / Daikin / AmanaE2

Goodman Code E2: Pressure Switch Stuck Open

7-segment display showing E2

Goodman / Daikin / AmanaE3

Goodman Code E3: Pressure Switch Stuck Closed

7-segment display showing E3

Goodman / Daikin / AmanaE4

Goodman Code E4: Open Rollout or Auxiliary Limit

7-segment display showing E4

Goodman / Daikin / AmanaE6

Goodman Code E6: Flame Sensed With Gas Valve Off

7-segment display showing E6

Goodman / Daikin / AmanaE7

Goodman Code E7: Igniter Fault / Open Circuit

7-segment display showing E7

Goodman / Daikin / AmanaE8

Goodman Code E8: Primary High-Limit Tripped

7-segment display showing E8

Goodman / Daikin / AmanaE9

Goodman Code E9: Reversed 115V Polarity / No Ground

7-segment display showing E9

Goodman / Daikin / AmanaEA

Goodman Code EA: Gas Valve Relay Circuit Fault

7-segment display showing EA

Goodman / Daikin / AmanaEC

Goodman Code EC: ComfortNet / Communicating Fault

7-segment display showing EC

Goodman / Daikin / Amanab0

Goodman / Daikin Code b0: Blower Motor Not Running

7-segment display showing b0

Goodman / Daikin / Amanab1

Goodman / Daikin Code b1: Blower Communication Error

7-segment display showing b1

Goodman / Daikin / Amanab3

Goodman / Daikin Code b3: Blower High Static / Power Limit

7-segment display showing b3

Goodman / Daikin / Amanab5

Goodman / Daikin Code b5: Blower Locked Rotor Fault

7-segment display showing b5

Goodman / Daikin / Amanad0

Goodman / Daikin Code d0: No Network Data on Bus

7-segment display showing d0

Rheem / Ruud10

Rheem / Ruud Code 10: One-Hour Ignition Lockout

Dual 7-segment display showing 10

Rheem / Ruud11

Rheem / Ruud Code 11: Failed Ignition Trial

Dual 7-segment display showing 11

Rheem / Ruud12

Rheem / Ruud Code 12: Low Flame Signal Warning

Dual 7-segment display showing 12

Rheem / Ruud13

Rheem / Ruud Code 13: Flame Lost After Ignition

Dual 7-segment display showing 13

Rheem / Ruud14

Rheem / Ruud Code 14: Flame Sensed Without Gas Call

Dual 7-segment display showing 14

Rheem / Ruud20

Rheem / Ruud Code 20: Gas Valve Circuit Fault

Dual 7-segment display showing 20

Rheem / Ruud22

Rheem / Ruud Code 22: Main High-Limit Switch Open

Dual 7-segment display showing 22

Rheem / Ruud26

Rheem / Ruud Code 26: Line Voltage Polarity / Ground Fault

Dual 7-segment display showing 26

Rheem / Ruud30

Rheem / Ruud Code 30: Blower Motor Comm / Fault

Dual 7-segment display showing 30

Rheem / Ruud33

Rheem / Ruud Code 33: Limit Switch Lockout (Repeated Trips)

Dual 7-segment display showing 33

Rheem / Ruud44

Rheem / Ruud Code 44: Low-Fire Pressure Switch Open

Dual 7-segment display showing 44

Rheem / Ruud45

Rheem / Ruud Code 45: Low-Fire Pressure Switch Closed

Dual 7-segment display showing 45

Rheem / Ruud55

Rheem / Ruud Code 55: High-Fire Pressure Switch Closed

Dual 7-segment display showing 55

Rheem / Ruud58

Rheem / Ruud Code 58: Condensate Water Sensor Triggered

Dual 7-segment display showing 58

Rheem / Ruud59

Rheem / Ruud Code 59: Condensate Sensor Lockout

Dual 7-segment display showing 59

Rheem / Ruud61

Rheem / Ruud Code 61: Inducer Motor Comm / Speed Fault

Dual 7-segment display showing 61

Rheem / Ruud66

Rheem / Ruud Code 66: A2L Refrigerant Mitigation

7-segment display 66 / continuous blower airflow

York / Coleman / Luxaire1-FLASH

York / Coleman / Luxaire 1-FLASH: York / Coleman 1 Flash: Flame Failed (Retry)

1 red flash on control board LED

York / Coleman / Luxaire2-FLASH

York / Coleman / Luxaire 2-FLASH: York / Coleman 2 Flashes: Pressure Switch Stuck Closed

2 red flashes on control board LED

York / Coleman / Luxaire3-FLASH

York / Coleman / Luxaire 3-FLASH: York / Coleman 3 Flashes: Pressure Switch Stuck Open

3 red flashes on control board LED

York / Coleman / Luxaire5-FLASH

York / Coleman / Luxaire 5-FLASH: York / Coleman 5 Flashes: Flame Sensed Without Call

5 red flashes on control board LED

York / Coleman / Luxaire6-FLASH

York / Coleman / Luxaire 6-FLASH: York / Coleman 6 Flashes: 1-Hour Ignition Lockout

6 red flashes on control board LED

York / Coleman / Luxaire7-FLASH

York / Coleman / Luxaire 7-FLASH: York / Coleman 7 Flashes: Ignition Retry Limit

7 red flashes on control board LED

York / Coleman / Luxaire8-FLASH

York / Coleman / Luxaire 8-FLASH: York / Coleman 8 Flashes: Repeated Flame Loss

8 red flashes on control board LED

York / Coleman / Luxaire9-FLASH

York / Coleman / Luxaire 9-FLASH: York / Coleman 9 Flashes: Reversed Polarity / Ground

9 red flashes on control board LED

York / Coleman / Luxaire10-FLASH

York / Coleman / Luxaire 10-FLASH: York / Coleman 10 Flashes: Gas Valve Circuit Fault

10 red flashes on control board LED

York / Coleman / LuxaireRED-SOLID

York / Coleman / Luxaire RED-SOLID: York / Coleman Solid Red LED: Board Fault / Rollout

Continuous solid red LED (unblinking)

York / Coleman / LuxaireRAPID-AMBER

York / Coleman / Luxaire RAPID-AMBER: York / Coleman Rapid Amber: Weak Flame Current

Rapid amber LED flashing during heat

Mitsubishi ElectricP1

Mitsubishi Code P1: Intake Air Thermistor Error

1 LED flash / P1 on wired remote

Mitsubishi ElectricP2

Mitsubishi Code P2: Liquid Pipe Thermistor Error

2 LED flashes / P2 on wired remote

Mitsubishi ElectricP4

Mitsubishi Code P4: Condensate Drain Sensor Open

4 LED flashes / P4 on wired remote

Mitsubishi ElectricP5

Mitsubishi Code P5: Condensate Drain Pump Overflow

5 LED flashes / P5 on wired remote

Mitsubishi ElectricP8

Mitsubishi Code P8: Pipe Temperature Abnormality

8 LED flashes / P8 on wired remote

Mitsubishi ElectricP9

Mitsubishi Code P9: Two-Phase Pipe Thermistor Error

9 LED flashes / P9 on wired remote

Mitsubishi ElectricU1

Mitsubishi Code U1: High Pressure Switch Trip

U1 fault code on controller

Mitsubishi ElectricU2

Mitsubishi Code U2: High Compressor Discharge Temp

U2 fault code on controller

Mitsubishi ElectricU3

Mitsubishi Code U3: Discharge Thermistor Open/Short

U3 fault code on controller

Mitsubishi ElectricU4

Mitsubishi Code U4: Outdoor Defrost/Ambient Sensor

U4 fault code on controller

Mitsubishi ElectricE6

Mitsubishi Code E6: Indoor-to-Outdoor Serial Comm Error

E6 code on controller / rapid blinking timer LED

Mitsubishi ElectricE7

Mitsubishi Code E7: Serial Transmission Reception Error

E7 code on controller

Mitsubishi ElectricE9

Mitsubishi Code E9: Indoor-Outdoor Transmit Timeout

E9 code on controller

Google NestN72

Nest Code N72: Power Wire Rh/Rc Not Detected

On-screen Nest alert N72

Google NestN73

Nest Code N73: No Power Detected on Rc Wire

On-screen Nest alert N73

Google NestN74

Nest Code N74: No Power Detected on Rh Wire

On-screen Nest alert N74

Google NestN260

Nest Code N260: C-Wire or Power Connector Needed

On-screen Nest alert N260

Google NestE73

Nest Code E73: No Power to Rc Wire

On-screen Nest error E73

Google NestE74

Nest Code E74: No Power to Rh Wire

On-screen Nest error E74

Google NestE79

Nest Code E79: No Power / Common C-Wire Fault

On-screen Nest error E79

Google NestE80

Nest Code E80: No Power on Y1 Cooling Wire

On-screen Nest error E80

Google NestE103

Nest Code E103: Overcurrent on Y1 Cooling Wire

On-screen Nest error E103

Google NestE195

Nest Code E195: Power Cut to R Wire

On-screen Nest error E195

ecobeeAUX-ALERT

ecobee AUX-ALERT: ecobee Alert: Auxiliary Heat Running Too Long

On-screen ecobee Aux Heat Runtime Alert

ecobeeCOOL-FAIL

ecobee COOL-FAIL: ecobee Alert: Cooling Failed to Reach Setpoint

On-screen ecobee Cooling Alert

ecobeeHEAT-FAIL

ecobee HEAT-FAIL: ecobee Alert: Heating Failed to Reach Setpoint

On-screen ecobee Heating Alert

ecobeeOB-VALVE

ecobee OB-VALVE: ecobee Setup: Heat Pump Blowing Opposite Air (O/B)

Warm air on Cool or Cool air on Heat

ecobeeBROWNOUT

ecobee BROWNOUT: ecobee Screen Blank / Rebooting on Heating Call

Thermostat blanks out during burner ignition

ecobeePEK-FAULT

ecobee PEK-FAULT: ecobee Power Extender Kit (PEK) Wiring Alert

Missing R/C or Y/W detection on PEK

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Core Spec

What primary metric defines Furnace, Heat Pump & A2L Fault Code Reference?

Furnace, Heat Pump & A2L Fault Code Reference anchors on Federal AC Minimum at 13.4 - 14.3 SEER2 and Cleaner Refrigerants at R-454B or R-32, sourced from federal datasets and OEM filings.

Bounds

How are Federal 25C Credit figures verified for Furnace, Heat Pump & A2L Fault Code Reference?

Federal 25C Credit: Ended Dec 31, 2025 and Covered Homes: Single-Family & Townhomes inside Furnace, Heat Pump & A2L Fault Code Reference derive directly from public government data with zero paid boosts.

Exclusions

Who falls outside Furnace, Heat Pump & A2L Fault Code Reference applicability?

Furnace, Heat Pump & A2L Fault Code Reference addresses single-family and townhome systems only; commercial systems and permit sizing need local engineering review.

SEER2 Rules

How do federal regional rules govern Furnace, Heat Pump & A2L Fault Code Reference?

Regional efficiency rules enforce 13.4 North and 14.3 South SEER2 minimums around Furnace, Heat Pump & A2L Fault Code Reference.

A2L Spec

Does the under-700 GWP rule affect Furnace, Heat Pump & A2L Fault Code Reference?

2026 residential split equipment covered under Furnace, Heat Pump & A2L Fault Code Reference transitions to R-454B or R-32 with UL 60335-2-40 sensors.

2026 Tax

Are 2026 federal tax credits active on Furnace, Heat Pump & A2L Fault Code Reference?

IRS 25C ended Dec 31, 2025 under Public Law 119-21 ($0 in 2026); consult state HEAR programs alongside Furnace, Heat Pump & A2L Fault Code Reference.

Credentials

What technician license applies to Furnace, Heat Pump & A2L Fault Code Reference work?

Pressurized refrigerant lines and 240V controls noted in Furnace, Heat Pump & A2L Fault Code Reference mandate EPA Section 608 and state mechanical licensing.

Audit

How can owners cross-check quotes on Furnace, Heat Pump & A2L Fault Code Reference?

Confirm AHRI reference numbers, <=0.50 in. w.c. static pressure limits, and active board registration when reviewing Furnace, Heat Pump & A2L Fault Code Reference.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  2. Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
  3. Goodman / Daikin / Amana Residential Literature Library — Daikin Comfort Technologies, Goodman Public Library (retrieved 2026-11-23)
  4. Trane / American Standard Residential HVAC Literature & Fault Reference — Trane Technologies (Public Docs), Trane LitWeb Public (retrieved 2026-11-23)
  5. Lennox Residential Public Product & Warranty Documentation — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
  6. Mitsubishi Electric Trane HVAC US MyLinkDrive Service & Fault Manuals — Mitsubishi Electric Trane HVAC US, MyLinkDrive Public (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 2 pages.

Comparable HVAC Climate & Cost Metros