Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed
Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or failing diaphragm. Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed across single-family housing. Carrier Dual-Pressure Switch Diagnostic Table — Code 43: Carrier / Bryant / Payne 43: Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or failing diaphragm. Pro fix: Verify factory barb tubing diagram and test switch closure pressures independently on a digital manometer..
- Manufacturer Family
- Carrier / Bryant / Payne
- Control System
- Gas Furnace
- Fault Code
- 43
- LED Blink Sequence
- 4 slow amber flashes followed by 3 fast amber flashes
- Slow / Fast Pulses
- 4 slow / 3 fast
- Control Supply Voltage
- 24 VAC Board / 5 min Breaker Wait
How do you identify fault code 43 on Carrier / Bryant / Payne diagnostic LEDs?
Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or failing diaphragm.
| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| Slow LED Pulses | 4 x 520 ms amber (3,200 ms) | First digit / slow code cadence |
| Fast LED Pulses | 3 x 200 ms red (1,140 ms) | Second digit / rapid fault pulses |
| Total Cycle Period | 5,540 ms | Includes 1,200 ms pause between repeats |
| External Static Ceiling | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| 24VAC Control Supply | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |
Which homeowner-safe checks can verify external causes before calling service?
Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.
External Verification Checklist
- Do not swap rubber tubes on dual pressure switches
- Inspect condensate drain line flow
Professional Diagnostic Scope
Which adjacent OEM fault codes share similar lockout symptoms?
Cross-check related diagnostic LED sequences if cycling power clears code 43 temporarily or alternates with pressure, flame, or limit switch lockouts.
Code 31: Pressure Switch Did Not Close or Reopened
Code 33: Limit Circuit Fault (High-Temp Cutoff)
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Why does Carrier / Bryant / Payne blink fault code 43?
Carrier / Bryant / Payne Gas Furnace code 43 indicates: Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or fail.
What LED timing marks Carrier / Bryant / Payne code 43?
On Carrier / Bryant / Payne boards, 4 slow amber flashes followed by 3 fast amber flashes fires 4 slow and 3 fast LED pulses repeatedly.
Which external check applies first to Carrier / Bryant / Payne 43?
First on Carrier / Bryant / Payne code 43: Do not swap rubber tubes on dual pressure switches; secondary check: Inspect condensate drain line flow.
What does Carrier Dual-Pressure Switch Diagnostic Table — Code 43 document for code 43?
Carrier / Bryant / Payne 43: Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to sw — recorded under Carrier Dual-Pressure Switch Diagnostic Table — Code 43 for Carrier / Bryant / Payne Gas Furnace equipment.
How do techs repair Carrier / Bryant / Payne Gas Furnace fault 43?
Authorized repair on Carrier / Bryant / Payne code 43: Verify factory barb tubing diagram and test switch closure pressures independently on a digital manometer. (also inspect: confirm condensate drain trap clearance).
Why avoid jumping switches on Carrier / Bryant / Payne code 43?
Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 43.
Will flipping the breaker clear Carrier / Bryant / Payne code 43?
One brief power cycle resets transient Carrier / Bryant / Payne code 43, while repeat trips need mechanical testing.
What license applies to Carrier / Bryant / Payne Gas Furnace fault 43?
Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 43.
Sources
Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.