Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed

Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or failing diaphragm. Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Carrier / Bryant / Payne 43: Low Pressure Switch Open While High Closed across single-family housing. Carrier Dual-Pressure Switch Diagnostic Table — Code 43: Carrier / Bryant / Payne 43: Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or failing diaphragm. Pro fix: Verify factory barb tubing diagram and test switch closure pressures independently on a digital manometer..

Manufacturer Family
Carrier / Bryant / Payne
Control System
Gas Furnace
Fault Code
43
LED Blink Sequence
4 slow amber flashes followed by 3 fast amber flashes
Slow / Fast Pulses
4 slow / 3 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 43 on Carrier / Bryant / Payne diagnostic LEDs?

Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or failing diaphragm.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Do not swap rubber tubes on dual pressure switches
  • Inspect condensate drain line flow
Licensed Technician

Professional Diagnostic Scope

Verify factory barb tubing diagram and test switch closure pressures independently on a digital manometer.

Carrier Dual-Pressure Switch Diagnostic Table — Code 43: Carrier / Bryant / Payne 43: Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or failing diaphragm.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 43 temporarily or alternates with pressure, flame, or limit switch lockouts.

Carrier / Bryant / PayneCode 31

Code 31: Pressure Switch Did Not Close or Reopened

Carrier / Bryant / PayneCode 33

Code 33: Limit Circuit Fault (High-Temp Cutoff)

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Carrier / Bryant / Payne #43

Why does Carrier / Bryant / Payne blink fault code 43?

Carrier / Bryant / Payne Gas Furnace code 43 indicates: Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to swapped hoses or fail.

Cadence

What LED timing marks Carrier / Bryant / Payne code 43?

On Carrier / Bryant / Payne boards, 4 slow amber flashes followed by 3 fast amber flashes fires 4 slow and 3 fast LED pulses repeatedly.

Check 1

Which external check applies first to Carrier / Bryant / Payne 43?

First on Carrier / Bryant / Payne code 43: Do not swap rubber tubes on dual pressure switches; secondary check: Inspect condensate drain line flow.

Manual Ref

What does Carrier Dual-Pressure Switch Diagnostic Table — Code 43 document for code 43?

Carrier / Bryant / Payne 43: Differential pressure switches reported inconsistent state (high switch closed while low switch open) due to sw — recorded under Carrier Dual-Pressure Switch Diagnostic Table — Code 43 for Carrier / Bryant / Payne Gas Furnace equipment.

Pro Fix

How do techs repair Carrier / Bryant / Payne Gas Furnace fault 43?

Authorized repair on Carrier / Bryant / Payne code 43: Verify factory barb tubing diagram and test switch closure pressures independently on a digital manometer. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Carrier / Bryant / Payne code 43?

Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 43.

Reset

Will flipping the breaker clear Carrier / Bryant / Payne code 43?

One brief power cycle resets transient Carrier / Bryant / Payne code 43, while repeat trips need mechanical testing.

Credentials

What license applies to Carrier / Bryant / Payne Gas Furnace fault 43?

Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 43.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)