Skip to main content
Goodman / Daikin / Amana · Gas Furnace · Fault Code E2

Goodman Code E2: Pressure Switch Stuck Open

Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust. Goodman Code E2: Pressure Switch Stuck Open benchmarks residential systems using Manufacturer Family set at Goodman / Daikin / Amana and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Goodman Code E2: Pressure Switch Stuck Open across single-family housing. Goodman Furnace Fault Table — E2: Goodman / Daikin / Amana E2: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust. Pro fix: Check negative draft vacuum with manometer and clear condensate collector box..

Manufacturer Family
Goodman / Daikin / Amana
Control System
Gas Furnace
Fault Code
E2
LED Blink Sequence
7-segment display showing E2
Slow / Fast Pulses
0 slow / 2 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code E2 on Goodman / Daikin / Amana diagnostic LEDs?

Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Inspect outdoor PVC exhaust/intake pipes for frost or leaves
  • Check condensate drain hose for kinks
Licensed Technician

Professional Diagnostic Scope

Check negative draft vacuum with manometer and clear condensate collector box.

Goodman Furnace Fault Table — E2: Goodman / Daikin / Amana E2: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code E2 temporarily or alternates with pressure, flame, or limit switch lockouts.

Goodman / Daikin / AmanaCode E5

Code E5: Open Fuse or Primary Limit Circuit Open

Goodman / Daikin / AmanaCode EE

Code EE / E0: Ignition Lockout or Flame Sense Fault

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Goodman / Daikin / Amana #E2

Why does Goodman / Daikin / Amana blink fault code E2?

Goodman / Daikin / Amana Gas Furnace code E2 indicates: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exhaust..

Cadence

What LED timing marks Goodman / Daikin / Amana code E2?

On Goodman / Daikin / Amana boards, 7-segment display showing E2 fires 0 slow and 2 fast LED pulses repeatedly.

Check 1

Which external check applies first to Goodman / Daikin / Amana E2?

First on Goodman / Daikin / Amana code E2: Inspect outdoor PVC exhaust/intake pipes for frost or leaves; secondary check: Check condensate drain hose for kinks.

Manual Ref

What does Goodman Furnace Fault Table — E2 document for code E2?

Goodman / Daikin / Amana E2: Draft pressure switch did not close after inducer startup due to condensate clog, cracked hose, or blocked exha — recorded under Goodman Furnace Fault Table — E2 for Goodman / Daikin / Amana Gas Furnace equipment.

Pro Fix

How do techs repair Goodman / Daikin / Amana Gas Furnace fault E2?

Authorized repair on Goodman / Daikin / Amana code E2: Check negative draft vacuum with manometer and clear condensate collector box. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Goodman / Daikin / Amana code E2?

Combustion safety lockouts block CO or delayed ignition hazards on Goodman / Daikin / Amana code E2.

Reset

Will flipping the breaker clear Goodman / Daikin / Amana code E2?

One brief power cycle resets transient Goodman / Daikin / Amana code E2, while repeat trips need mechanical testing.

Credentials

What license applies to Goodman / Daikin / Amana Gas Furnace fault E2?

Licensed mechanical diagnostic credentials apply for Goodman / Daikin / Amana code E2.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Goodman / Daikin / Amana Residential Literature Library — Daikin Comfort Technologies, Goodman Public Library (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

Comparable HVAC Climate & Cost Metros