Skip to main content
Rheem / Ruud · Gas Furnace · Fault Code 13

Rheem / Ruud Code 13: Flame Lost After Ignition

Main burner ignited and proved flame initially, then dropped out mid-cycle. Rheem / Ruud Code 13: Flame Lost After Ignition benchmarks residential systems using Manufacturer Family set at Rheem / Ruud and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Rheem / Ruud Code 13: Flame Lost After Ignition across single-family housing. Rheem Gas Furnace Diagnostic Table — Code 13: Rheem / Ruud 13: Main burner ignited and proved flame initially, then dropped out mid-cycle. Pro fix: Measure dynamic inlet gas pressure during full burner load and test flame rod signal..

Manufacturer Family
Rheem / Ruud
Control System
Gas Furnace
Fault Code
13
LED Blink Sequence
Dual 7-segment display showing 13
Slow / Fast Pulses
1 slow / 3 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 13 on Rheem / Ruud diagnostic LEDs?

Main burner ignited and proved flame initially, then dropped out mid-cycle. Rheem / Ruud Code 13: Flame Lost After Ignition uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Check if gas meter or regulator is whistling or cycling
Licensed Technician

Professional Diagnostic Scope

Measure dynamic inlet gas pressure during full burner load and test flame rod signal.

Rheem Gas Furnace Diagnostic Table — Code 13: Rheem / Ruud 13: Main burner ignited and proved flame initially, then dropped out mid-cycle.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 13 temporarily or alternates with pressure, flame, or limit switch lockouts.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Rheem / Ruud #13

Why does Rheem / Ruud blink fault code 13?

Rheem / Ruud Gas Furnace code 13 indicates: Main burner ignited and proved flame initially, then dropped out mid-cycle..

Cadence

What LED timing marks Rheem / Ruud code 13?

On Rheem / Ruud boards, Dual 7-segment display showing 13 fires 1 slow and 3 fast LED pulses repeatedly.

Check 1

Which external check applies first to Rheem / Ruud 13?

First on Rheem / Ruud code 13: Check if gas meter or regulator is whistling or cycling; secondary check: inspect main air filter restriction.

Manual Ref

What does Rheem Gas Furnace Diagnostic Table — Code 13 document for code 13?

Rheem / Ruud 13: Main burner ignited and proved flame initially, then dropped out mid-cycle. — recorded under Rheem Gas Furnace Diagnostic Table — Code 13 for Rheem / Ruud Gas Furnace equipment.

Pro Fix

How do techs repair Rheem / Ruud Gas Furnace fault 13?

Authorized repair on Rheem / Ruud code 13: Measure dynamic inlet gas pressure during full burner load and test flame rod signal. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Rheem / Ruud code 13?

Combustion safety lockouts block CO or delayed ignition hazards on Rheem / Ruud code 13.

Reset

Will flipping the breaker clear Rheem / Ruud code 13?

One brief power cycle resets transient Rheem / Ruud code 13, while repeat trips need mechanical testing.

Credentials

What license applies to Rheem / Ruud Gas Furnace fault 13?

Licensed mechanical diagnostic credentials apply for Rheem / Ruud code 13.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Rheem / Ruud Residential Heat Pump & Furnace Documentation (B-Terminal Valve) — Rheem Manufacturing, Rheem Residential Specs (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

Comparable HVAC Climate & Cost Metros