Carrier / Bryant / Payne 11: No Previous Fault Stored in Memory

Control board self-test indicates no prior stored fault codes in volatile memory or memory cleared on power cycle. Carrier / Bryant / Payne 11: No Previous Fault Stored in Memory benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Carrier / Bryant / Payne 11: No Previous Fault Stored in Memory across single-family housing. Carrier Gas Furnace Diagnostic Table — Code 11: Carrier / Bryant / Payne 11: Control board self-test indicates no prior stored fault codes in volatile memory or memory cleared on power cycle. Pro fix: Verify control board 24VAC R-to-C supply and inspect fault history only after an active trip before cycling door switch..

Manufacturer Family
Carrier / Bryant / Payne
Control System
Gas Furnace
Fault Code
11
LED Blink Sequence
1 slow amber flash followed by 1 fast amber flash
Slow / Fast Pulses
1 slow / 1 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 11 on Carrier / Bryant / Payne diagnostic LEDs?

Control board self-test indicates no prior stored fault codes in volatile memory or memory cleared on power cycle.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Confirm normal thermostat heat/cool call response
  • Wait 15 minutes after thermostat call before checking status LED
Licensed Technician

Professional Diagnostic Scope

Verify control board 24VAC R-to-C supply and inspect fault history only after an active trip before cycling door switch.

Carrier Gas Furnace Diagnostic Table — Code 11: Carrier / Bryant / Payne 11: Control board self-test indicates no prior stored fault codes in volatile memory or memory cleared on power cycle.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 11 temporarily or alternates with pressure, flame, or limit switch lockouts.

Carrier / Bryant / PayneCode 31

Code 31: Pressure Switch Did Not Close or Reopened

Carrier / Bryant / PayneCode 33

Code 33: Limit Circuit Fault (High-Temp Cutoff)

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Carrier / Bryant / Payne #11

Why does Carrier / Bryant / Payne blink fault code 11?

Carrier / Bryant / Payne Gas Furnace code 11 indicates: Control board self-test indicates no prior stored fault codes in volatile memory or memory cleared on power cycle..

Cadence

What LED timing marks Carrier / Bryant / Payne code 11?

On Carrier / Bryant / Payne boards, 1 slow amber flash followed by 1 fast amber flash fires 1 slow and 1 fast LED pulses repeatedly.

Check 1

Which external check applies first to Carrier / Bryant / Payne 11?

First on Carrier / Bryant / Payne code 11: Confirm normal thermostat heat/cool call response; secondary check: Wait 15 minutes after thermostat call before checking status LED.

Manual Ref

What does Carrier Gas Furnace Diagnostic Table — Code 11 document for code 11?

Carrier / Bryant / Payne 11: Control board self-test indicates no prior stored fault codes in volatile memory or memory cleared on power cyc — recorded under Carrier Gas Furnace Diagnostic Table — Code 11 for Carrier / Bryant / Payne Gas Furnace equipment.

Pro Fix

How do techs repair Carrier / Bryant / Payne Gas Furnace fault 11?

Authorized repair on Carrier / Bryant / Payne code 11: Verify control board 24VAC R-to-C supply and inspect fault history only after an active trip before cycling door switch. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Carrier / Bryant / Payne code 11?

Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 11.

Reset

Will flipping the breaker clear Carrier / Bryant / Payne code 11?

One brief power cycle resets transient Carrier / Bryant / Payne code 11, while repeat trips need mechanical testing.

Credentials

What license applies to Carrier / Bryant / Payne Gas Furnace fault 11?

Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 11.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)