Skip to main content
589 ENERGY STAR Certified Series · Federal Window Standard

Window Air Conditioners: CEER Efficiency, BTU Sizing & Specs

ThermalSpec indexes 589 ENERGY STAR certified residential room air conditioner series spanning 12.0 to 17.6 CEER (cohort median 15.0 CEER and 531.9 kWh/yr typical energy use), including 203 variable-speed inverter Midea models. Window AC units separate evaporator and condenser airflow outdoors under federal efficiency standards, delivering markedly higher efficiency than single-hose portable ACs.

Certified RAC Series
589
Cohort Median CEER
15.0 CEER
CEER Efficiency Span
12.0-17.6 CEER
Median Annual Draw
532 kWh/yr
Standard Supply
115V / 230V NEMA
Federal Standard
DOE Room AC Minimum
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Residential air conditioning and airflow specifications. ThermalSpec Editorial Photography
Window & Room AC CEER Distribution across 589 certified series (12.0 to 17.6 CEER)
Top Certified Series Window & Room AC CEER Distribution Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. Top Certified Series sits at 17.6 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 17.6 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8This series

Which ENERGY STAR window air conditioner series achieve the highest CEER?

Variable-speed inverter window units—such as saddle-mount and U-shaped R-32 series—reach up to 17.6 CEER, reducing annual kWh draw by 40% to 80% compared with federal baseline window ACs. Filter all 30 top-ranked certified series below.

Showing 30 records
Midea MWEUWA-12CRFN8-BCP0 16.0 CEER562.5 kWh/yr12,000 BTU/hR-322
Perfect aire 1PACV10000 16.0 CEER468.8 kWh/yr10,000 BTU/hR-322
Perfect aire 1PACV12000 16.0 CEER562.5 kWh/yr12,000 BTU/hR-322
DELLA 048-TL-W10KI 15.0 CEER500.0 kWh/yr10,000 BTU/hR-322
DELLA 048-TL-W12KI 15.0 CEER600.0 kWh/yr12,000 BTU/hR-322
DELLA 048-TL-W8KI 15.0 CEER400.0 kWh/yr8,000 BTU/hR-322
Midea MAW18R2VWT 15.0 CEER900.0 kWh/yr18,000 BTU/hR-322
Midea MWCUWA-12CRFN8-BCN10 15.0 CEER600.0 kWh/yr12,000 BTU/hR-322
Noma iQ 143-0087-4 15.0 CEER400.0 kWh/yr8,000 BTU/hR-322
Noma iQ 143-0088-2 15.0 CEER500.0 kWh/yr10,000 BTU/hR-322
Perfect aire 1PACV8000 15.0 CEER400.0 kWh/yr8,000 BTU/hR-322
ROVSUN TIWC-08CRD1 15.0 CEER400.0 kWh/yr8,000 BTU/hR-322
TCL T08WQ2S 15.0 CEER400.0 kWh/yr8,000 BTU/hR-322
TCL T10WQ2S 15.0 CEER500.0 kWh/yr10,000 BTU/hR-322
TCL T12WQ2S 15.0 CEER600.0 kWh/yr12,000 BTU/hR-322
TCL T15WQ2S 14.4 CEER781.3 kWh/yr15,000 BTU/hR-322
TCL T18WQ2S 14.4 CEER937.5 kWh/yr18,000 BTU/hR-322
Midea MAW25R2VWT 13.3 CEER1353.4 kWh/yr24,000 BTU/hR-322
TCL T24WQ2S 12.7 CEER1417.3 kWh/yr24,000 BTU/hR-322
Midea MAH09B1AGR 17.6 CEER404.8 kWh/yr9,500 BTU/hR-321
Midea MAH09H1AGR 17.6 CEER404.8 kWh/yr9,500 BTU/hR-321
Midea MAH09N1AGR 17.6 CEER404.8 kWh/yr9,500 BTU/hR-321
Midea MAH09S1AGR 17.6 CEER404.8 kWh/yr9,500 BTU/hR-321
Midea MAH09W1AGR 17.6 CEER404.8 kWh/yr9,500 BTU/hR-321
Midea MWCUPWHP-09HEFN8-BCL1 17.6 CEER404.8 kWh/yr9,500 BTU/hR-321
Midea MWCUPWHP-09HEFN8-BCL1N 17.6 CEER404.8 kWh/yr9,500 BTU/hR-321
Kuhl KCVS08B10B 17.0 CEER383.8 kWh/yr8,700 BTU/hR-321
Gradient CCHP11 16.8 CEER415.2 kWh/yr9,300 BTU/hR-321
Kuhl KCVS12B30B 16.8 CEER567.0 kWh/yr12,700 BTU/hR-321
ZAFRO 54091EWA0-8K-ZAZ 16.3 CEER372.7 kWh/yr8,100 BTU/hR-321

How many BTU does a residential window air conditioner need by room size?

Standard residential room cooling sizes near ~20 BTU/h per sq ft of floor area (e.g., 5,000-6,000 BTU/h for 150-250 sq ft bedrooms; 8,000-10,000 BTU/h for 350-450 sq ft rooms; 12,000 BTU/h on 115V circuits up to ~550 sq ft). Oversizing causes clammy indoor humidity from short cycling.

Which homeowner profile fits each equipment or service path?

Match your home envelope, utility rate tier, and system age against these four verified decision profiles before signing contractor bids.

Scenario Fit

Ideal for Bedrooms & 115V Circuits

Pick 8,000-10,000 BTU/h inverter R-32 saddle/window models drawing <450 kWh/yr on standard 15A outlets.

Scenario Fit

Recommended Over Portable ACs When

Double-hung or sliding windows permit mounting; window units reject condenser heat cleanly outdoors without negative room pressure.

Scenario Fit

Requires 230V Dedicated Circuit When

Selecting 15,000-24,000+ BTU/h high-capacity window or through-wall sleeve units.

Scenario Fit

Skip Window ACs If

HOA bans exterior window overhang or casement windows lack vertical clearance—evaluate dual-hose SACC portable ACs or ductless mini-splits.

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Window air conditioners, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Standard window brackets require sash anchoring and side-panel air sealing; unsealed accordion panels leak humid outdoor air.
  • Through-wall installations require non-louvered chassis sleeves with exterior rear airflow clearance to avoid recirculation trips.
  • 12,000+ BTU/h units can trip shared 15A 115V bedroom circuits alongside space heaters or hair dryers.
Homeowner ScenarioRecommended Verification Path
Single-Room Quiet CoolingCheck inverter variable-speed models (R-32, >=15 CEER) that throttle compressor RPM overnight.
Whole-Home Multi-Room NeedsCompare central heat pump splits or multi-zone ductless mini-splits under /mini-splits/.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

PAA · Comparison

Which is better, central AC or a window AC?

Window ACs (median 15.0 CEER, 532 kWh/yr) cool single rooms without attic duct losses, while central split AC (13.4-14.3+ SEER2) delivers quieter whole-home dehumidification and MERV 8-13 filtration.

PAA · Sizing

How many BTU is a normal window AC?

Typical 115V residential bedroom and living-room window ACs span 5,000 to 12,000 BTU/h (~20 BTU/h per sq ft), while 230V through-wall models scale from 14,000 to 25,000 BTU/h.

PAA · Mounting

Do air conditioners need a window?

Window units require a standard window or structural wall sleeve to dump condenser heat outdoors; central splits, mini-splits, and portable ACs with exhaust hoses serve windowless or HOA-restricted rooms.

PAA · Safety

Can you run a window AC safely inside a house?

Yes—mount the unit tilted slightly outward per manufacturer drains, plug directly into a grounded 115V/230V wall receptacle (no lightweight extension cords), and seal side curtains.

Midea Series

Why do Midea window ACs show high CEER ratings in ENERGY STAR data?

ThermalSpec indexes 203 Midea room AC series using variable-speed inverter compressors and R-32 refrigerant (reaching up to 17.6 CEER across saddle/straddle designs).

CEER vs SEER2

What is the difference between CEER and SEER2?

CEER (Combined Energy Efficiency Ratio) applies to window, through-wall, and portable room ACs under federal room-AC rules including standby power, whereas SEER2 governs central split systems.

A2L / R-32

What refrigerant do new ENERGY STAR window ACs use in 2026?

Most current high-efficiency ENERGY STAR room air conditioners use R-32 (GWP 675), meeting the federal <700 GWP Technology Transitions cap.

Cost Math

How much electricity does an ENERGY STAR window AC cost per summer?

At 532 kWh/yr cohort median and 16.33 c/kWh US median power, typical seasonal electricity runs roughly $87/yr depending on hours run.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32(b) Room Air Conditioners & 10 CFR 430.32(cc) Portable Air Conditioners — U.S. Department of Energy / eCFR, eCFR 2026 (retrieved 2026-11-24)
  3. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 4 pages.

Comparable HVAC Climate & Cost Metros