Carrier / Bryant / Payne · Gas Furnace · Fault Code 13

Carrier / Bryant / Payne 13: Limit Circuit Lockout (3-Hour Thermal Hold)

Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours. Carrier / Bryant / Payne 13: Limit Circuit Lockout (3-Hour Thermal Hold) benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Carrier Gas Furnace Diagnostic Table — Code 13: Carrier / Bryant / Payne 13: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours. Pro fix: Measure total external static pressure (<= 0.50 in. w.c.), inspect heat exchanger for cracks, and verify blower CFM tap..

Manufacturer Family
Carrier / Bryant / Payne
Control System
Gas Furnace
Fault Code
13
LED Blink Sequence
1 slow amber flash followed by 3 fast amber flashes
Slow / Fast Pulses
1 slow / 3 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 13 on Carrier / Bryant / Payne diagnostic LEDs?

Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Replace clogged 1-inch air filter and open all supply/return grilles
  • Do NOT repeatedly reset power if rollout switch is tripped
Licensed Technician

Professional Diagnostic Scope

Measure total external static pressure (<= 0.50 in. w.c.), inspect heat exchanger for cracks, and verify blower CFM tap.

Carrier Gas Furnace Diagnostic Table — Code 13: Carrier / Bryant / Payne 13: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out gas ignition for 3 hours.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 13 temporarily or alternates with pressure, flame, or limit switch lockouts.

Carrier / Bryant / PayneCode 31

Code 31: Pressure Switch Did Not Close or Reopened

Carrier / Bryant / PayneCode 33

Code 33: Limit Circuit Fault (High-Temp Cutoff)

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Carrier / Bryant / Payne #13

Why does Carrier / Bryant / Payne blink fault code 13?

Carrier / Bryant / Payne Gas Furnace code 13 indicates: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Code 33), locking out .

Cadence

What LED timing marks Carrier / Bryant / Payne code 13?

On Carrier / Bryant / Payne boards, 1 slow amber flash followed by 3 fast amber flashes fires 1 slow and 3 fast LED pulses repeatedly.

Check 1

Which external check applies first to Carrier / Bryant / Payne 13?

First on Carrier / Bryant / Payne code 13: Replace clogged 1-inch air filter and open all supply/return grilles; secondary check: Do NOT repeatedly reset power if rollout switch is tripped.

Manual Ref

What does Carrier Gas Furnace Diagnostic Table — Code 13 document for code 13?

Carrier / Bryant / Payne 13: Primary high-temperature limit or manual rollout switch remained open longer than 3 minutes (escalated from Cod — recorded under Carrier Gas Furnace Diagnostic Table — Code 13 for Carrier / Bryant / Payne Gas Furnace equipment.

Pro Fix

How do techs repair Carrier / Bryant / Payne Gas Furnace fault 13?

Authorized repair on Carrier / Bryant / Payne code 13: Measure total external static pressure (<= 0.50 in. w.c.), inspect heat exchanger for cracks, and verify blower CFM tap. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Carrier / Bryant / Payne code 13?

Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 13.

Reset

Will flipping the breaker clear Carrier / Bryant / Payne code 13?

One brief power cycle resets transient Carrier / Bryant / Payne code 13, while repeat trips need mechanical testing.

Credentials

What license applies to Carrier / Bryant / Payne Gas Furnace fault 13?

Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 13.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)