Lennox Code 250: Primary High-Limit Switch Open
High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. Lennox Code 250: Primary High-Limit Switch Open benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 250: Primary High-Limit Switch Open across single-family housing. Lennox Diagnostic Codes — 250: Lennox 250: High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. Pro fix: Measure return-to-supply temperature rise and total static pressure (<= 0.50 in. w.c.)..
- Manufacturer Family
- Lennox
- Control System
- Gas Furnace
- Fault Code
- 250
- LED Blink Sequence
- 7-segment LED showing 250
- Slow / Fast Pulses
- 2 slow / 5 fast
- Control Supply Voltage
- 24 VAC Board / 5 min Breaker Wait
How do you identify fault code 250 on Lennox diagnostic LEDs?
High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. Lennox Code 250: Primary High-Limit Switch Open uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.
| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| Slow LED Pulses | 2 x 520 ms amber (1,600 ms) | First digit / slow code cadence |
| Fast LED Pulses | 5 x 200 ms red (1,900 ms) | Second digit / rapid fault pulses |
| Total Cycle Period | 4,700 ms | Includes 1,200 ms pause between repeats |
| External Static Ceiling | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| 24VAC Control Supply | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |
Which homeowner-safe checks can verify external causes before calling service?
Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.
External Verification Checklist
- Replace dirty furnace filter
- Check that return vents are not covered by rugs or furniture
Professional Diagnostic Scope
Which adjacent OEM fault codes share similar lockout symptoms?
Cross-check related diagnostic LED sequences if cycling power clears code 250 temporarily or alternates with pressure, flame, or limit switch lockouts.
Lennox Code 154 / E250: Primary Limit Open or Airflow Fault
Lennox Code 110: Low AC Line Voltage (< 90VAC)
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Why does Lennox blink fault code 250?
Lennox Gas Furnace code 250 indicates: High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger..
What LED timing marks Lennox code 250?
On Lennox boards, 7-segment LED showing 250 fires 2 slow and 5 fast LED pulses repeatedly.
Which external check applies first to Lennox 250?
First on Lennox code 250: Replace dirty furnace filter; secondary check: Check that return vents are not covered by rugs or furniture.
What does Lennox Diagnostic Codes — 250 document for code 250?
Lennox 250: High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. — recorded under Lennox Diagnostic Codes — 250 for Lennox Gas Furnace equipment.
How do techs repair Lennox Gas Furnace fault 250?
Authorized repair on Lennox code 250: Measure return-to-supply temperature rise and total static pressure (<= 0.50 in. w.c.). (also inspect: confirm condensate drain trap clearance).
Why avoid jumping switches on Lennox code 250?
Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 250.
Will flipping the breaker clear Lennox code 250?
One brief power cycle resets transient Lennox code 250, while repeat trips need mechanical testing.
What license applies to Lennox Gas Furnace fault 250?
Licensed mechanical diagnostic credentials apply for Lennox code 250.
Sources
Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.
- Lennox Residential Public Product & Warranty Documentation — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.