Lennox · Gas Furnace · Fault Code 250

Lennox Code 250: Primary High-Limit Switch Open

High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. Lennox Code 250: Primary High-Limit Switch Open benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 250: Primary High-Limit Switch Open across single-family housing. Lennox Diagnostic Codes — 250: Lennox 250: High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. Pro fix: Measure return-to-supply temperature rise and total static pressure (<= 0.50 in. w.c.)..

Manufacturer Family
Lennox
Control System
Gas Furnace
Fault Code
250
LED Blink Sequence
7-segment LED showing 250
Slow / Fast Pulses
2 slow / 5 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 250 on Lennox diagnostic LEDs?

High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. Lennox Code 250: Primary High-Limit Switch Open uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Replace dirty furnace filter
  • Check that return vents are not covered by rugs or furniture
Licensed Technician

Professional Diagnostic Scope

Measure return-to-supply temperature rise and total static pressure (<= 0.50 in. w.c.).

Lennox Diagnostic Codes — 250: Lennox 250: High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 250 temporarily or alternates with pressure, flame, or limit switch lockouts.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Lennox #250

Why does Lennox blink fault code 250?

Lennox Gas Furnace code 250 indicates: High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger..

Cadence

What LED timing marks Lennox code 250?

On Lennox boards, 7-segment LED showing 250 fires 2 slow and 5 fast LED pulses repeatedly.

Check 1

Which external check applies first to Lennox 250?

First on Lennox code 250: Replace dirty furnace filter; secondary check: Check that return vents are not covered by rugs or furniture.

Manual Ref

What does Lennox Diagnostic Codes — 250 document for code 250?

Lennox 250: High-temperature limit switch tripped open due to low indoor airflow over the heat exchanger. — recorded under Lennox Diagnostic Codes — 250 for Lennox Gas Furnace equipment.

Pro Fix

How do techs repair Lennox Gas Furnace fault 250?

Authorized repair on Lennox code 250: Measure return-to-supply temperature rise and total static pressure (<= 0.50 in. w.c.). (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Lennox code 250?

Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 250.

Reset

Will flipping the breaker clear Lennox code 250?

One brief power cycle resets transient Lennox code 250, while repeat trips need mechanical testing.

Credentials

What license applies to Lennox Gas Furnace fault 250?

Licensed mechanical diagnostic credentials apply for Lennox code 250.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.