Lennox Code 113: High AC Line Voltage
Incoming line voltage exceeded control board upper voltage tolerance, risking transformer overheating. Lennox Code 113: High AC Line Voltage benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 113: High AC Line Voltage across single-family housing. Lennox Diagnostic Codes — 113: Lennox 113: Incoming line voltage exceeded control board upper voltage tolerance, risking transformer overheating. Pro fix: Verify 120VAC supply voltage with true-RMS meter and confirm 24VAC secondary transformer output..
- Manufacturer Family
- Lennox
- Control System
- Gas Furnace
- Fault Code
- 113
- LED Blink Sequence
- 7-segment LED showing 113
- Slow / Fast Pulses
- 1 slow / 1 fast
- Control Supply Voltage
- 24 VAC Board / 5 min Breaker Wait
How do you identify fault code 113 on Lennox diagnostic LEDs?
Incoming line voltage exceeded control board upper voltage tolerance, risking transformer overheating. Lennox Code 113: High AC Line Voltage uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.
| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| Slow LED Pulses | 1 x 520 ms amber (800 ms) | First digit / slow code cadence |
| Fast LED Pulses | 1 x 200 ms red (380 ms) | Second digit / rapid fault pulses |
| Total Cycle Period | 2,380 ms | Includes 1,200 ms pause between repeats |
| External Static Ceiling | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| 24VAC Control Supply | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |
Which homeowner-safe checks can verify external causes before calling service?
Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.
External Verification Checklist
- Check other household appliances for power surge symptoms
- Contact electric utility if voltage runs high
Professional Diagnostic Scope
Which adjacent OEM fault codes share similar lockout symptoms?
Cross-check related diagnostic LED sequences if cycling power clears code 113 temporarily or alternates with pressure, flame, or limit switch lockouts.
Lennox Code 154 / E250: Primary Limit Open or Airflow Fault
Lennox Code 110: Low AC Line Voltage (< 90VAC)
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Why does Lennox blink fault code 113?
Lennox Gas Furnace code 113 indicates: Incoming line voltage exceeded control board upper voltage tolerance, risking transformer overheating..
What LED timing marks Lennox code 113?
On Lennox boards, 7-segment LED showing 113 fires 1 slow and 1 fast LED pulses repeatedly.
Which external check applies first to Lennox 113?
First on Lennox code 113: Check other household appliances for power surge symptoms; secondary check: Contact electric utility if voltage runs high.
What does Lennox Diagnostic Codes — 113 document for code 113?
Lennox 113: Incoming line voltage exceeded control board upper voltage tolerance, risking transformer overheating. — recorded under Lennox Diagnostic Codes — 113 for Lennox Gas Furnace equipment.
How do techs repair Lennox Gas Furnace fault 113?
Authorized repair on Lennox code 113: Verify 120VAC supply voltage with true-RMS meter and confirm 24VAC secondary transformer output. (also inspect: confirm condensate drain trap clearance).
Why avoid jumping switches on Lennox code 113?
Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 113.
Will flipping the breaker clear Lennox code 113?
One brief power cycle resets transient Lennox code 113, while repeat trips need mechanical testing.
What license applies to Lennox Gas Furnace fault 113?
Licensed mechanical diagnostic credentials apply for Lennox code 113.
Sources
Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.
- Lennox Residential Public Product & Warranty Documentation — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)