Lennox Code 240: Low Flame Sense Current
Flame rectification signal dropped near minimum microamp floor during burner run. Lennox Code 240: Low Flame Sense Current benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 240: Low Flame Sense Current across single-family housing. Lennox Diagnostic Codes — 240: Lennox 240: Flame rectification signal dropped near minimum microamp floor during burner run. Pro fix: Measure DC microamps in series with flame rod and burnish silicon oxide glaze cleanly..
- Manufacturer Family
- Lennox
- Control System
- Gas Furnace
- Fault Code
- 240
- LED Blink Sequence
- 7-segment LED showing 240
- Slow / Fast Pulses
- 2 slow / 4 fast
- Control Supply Voltage
- 24 VAC Board / 5 min Breaker Wait
How do you identify fault code 240 on Lennox diagnostic LEDs?
Flame rectification signal dropped near minimum microamp floor during burner run. Lennox Code 240: Low Flame Sense Current uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.
| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| Slow LED Pulses | 2 x 520 ms amber (1,600 ms) | First digit / slow code cadence |
| Fast LED Pulses | 4 x 200 ms red (1,520 ms) | Second digit / rapid fault pulses |
| Total Cycle Period | 4,320 ms | Includes 1,200 ms pause between repeats |
| External Static Ceiling | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| 24VAC Control Supply | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |
Which homeowner-safe checks can verify external causes before calling service?
Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.
External Verification Checklist
- Schedule routine furnace cleaning and flame rod service
Professional Diagnostic Scope
Which adjacent OEM fault codes share similar lockout symptoms?
Cross-check related diagnostic LED sequences if cycling power clears code 240 temporarily or alternates with pressure, flame, or limit switch lockouts.
Lennox Code 154 / E250: Primary Limit Open or Airflow Fault
Lennox Code 110: Low AC Line Voltage (< 90VAC)
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Why does Lennox blink fault code 240?
Lennox Gas Furnace code 240 indicates: Flame rectification signal dropped near minimum microamp floor during burner run..
What LED timing marks Lennox code 240?
On Lennox boards, 7-segment LED showing 240 fires 2 slow and 4 fast LED pulses repeatedly.
Which external check applies first to Lennox 240?
First on Lennox code 240: Schedule routine furnace cleaning and flame rod service; secondary check: inspect main air filter restriction.
What does Lennox Diagnostic Codes — 240 document for code 240?
Lennox 240: Flame rectification signal dropped near minimum microamp floor during burner run. — recorded under Lennox Diagnostic Codes — 240 for Lennox Gas Furnace equipment.
How do techs repair Lennox Gas Furnace fault 240?
Authorized repair on Lennox code 240: Measure DC microamps in series with flame rod and burnish silicon oxide glaze cleanly. (also inspect: confirm condensate drain trap clearance).
Why avoid jumping switches on Lennox code 240?
Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 240.
Will flipping the breaker clear Lennox code 240?
One brief power cycle resets transient Lennox code 240, while repeat trips need mechanical testing.
What license applies to Lennox Gas Furnace fault 240?
Licensed mechanical diagnostic credentials apply for Lennox code 240.
Sources
Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.
- Lennox Residential Public Product & Warranty Documentation — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)