Skip to main content
Mitsubishi Electric · Mini-Split Heat Pump · Fault Code P2

Mitsubishi Code P2: Liquid Pipe Thermistor Error

Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. Mitsubishi Code P2: Liquid Pipe Thermistor Error benchmarks residential systems using Manufacturer Family set at Mitsubishi Electric and Control System set at Mini-Split Heat Pump. Values trace to primary federal, state, or OEM filings supporting Mitsubishi Code P2: Liquid Pipe Thermistor Error across single-family housing. Mitsubishi MyLinkDrive Service Manual — Code P2: Mitsubishi Electric P2: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. Pro fix: Measure TH2 sensor kohms at ambient pipe temp and inspect PCB plug CN44..

Manufacturer Family
Mitsubishi Electric
Control System
Mini-Split Heat Pump
Fault Code
P2
LED Blink Sequence
2 LED flashes / P2 on wired remote
Slow / Fast Pulses
0 slow / 2 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code P2 on Mitsubishi Electric diagnostic LEDs?

Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. Mitsubishi Code P2: Liquid Pipe Thermistor Error uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Do not open indoor control box while breaker is energized
Licensed Technician

Professional Diagnostic Scope

Measure TH2 sensor kohms at ambient pipe temp and inspect PCB plug CN44.

Mitsubishi MyLinkDrive Service Manual — Code P2: Mitsubishi Electric P2: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code P2 temporarily or alternates with pressure, flame, or limit switch lockouts.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Mitsubishi Electric #P2

Why does Mitsubishi Electric blink fault code P2?

Mitsubishi Electric Mini-Split Heat Pump code P2 indicates: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve..

Cadence

What LED timing marks Mitsubishi Electric code P2?

On Mitsubishi Electric boards, 2 LED flashes / P2 on wired remote fires 0 slow and 2 fast LED pulses repeatedly.

Check 1

Which external check applies first to Mitsubishi Electric P2?

First on Mitsubishi Electric code P2: Do not open indoor control box while breaker is energized; secondary check: inspect main air filter restriction.

Manual Ref

What does Mitsubishi MyLinkDrive Service Manual — Code P2 document for code P2?

Mitsubishi Electric P2: Indoor liquid-line coil thermistor (TH2) disconnected or out of resistance curve. — recorded under Mitsubishi MyLinkDrive Service Manual — Code P2 for Mitsubishi Electric Mini-Split Heat Pump equipment.

Pro Fix

How do techs repair Mitsubishi Electric Mini-Split Heat Pump fault P2?

Authorized repair on Mitsubishi Electric code P2: Measure TH2 sensor kohms at ambient pipe temp and inspect PCB plug CN44. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Mitsubishi Electric code P2?

Relay lockouts protect compressor windings on Mitsubishi Electric code P2.

Reset

Will flipping the breaker clear Mitsubishi Electric code P2?

One brief power cycle resets transient Mitsubishi Electric code P2, while repeat trips need mechanical testing.

Credentials

What license applies to Mitsubishi Electric Mini-Split Heat Pump fault P2?

EPA 608 clearance governs refrigerant work for Mitsubishi Electric code P2.

Sources

Verified numerical figures and rules trace to the 3 cited federal, state, or OEM documents listed below.

  1. Mitsubishi Electric Trane HVAC US MyLinkDrive Service & Fault Manuals — Mitsubishi Electric Trane HVAC US, MyLinkDrive Public (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

Comparable HVAC Climate & Cost Metros