Skip to main content
Google Nest · Smart Thermostat (24VAC) · Fault Code E103

Nest Code E103: Overcurrent on Y1 Cooling Wire

Shorted outdoor condenser contactor coil or pinched thermostat wire caused excessive 24VAC current on Y1. Nest Code E103: Overcurrent on Y1 Cooling Wire benchmarks residential systems using Manufacturer Family set at Google Nest and Control System set at Smart Thermostat (24VAC). Values trace to primary federal, state, or OEM filings supporting Nest Code E103: Overcurrent on Y1 Cooling Wire across single-family housing. Google Nest Support — Error E103: Google Nest E103: Shorted outdoor condenser contactor coil or pinched thermostat wire caused excessive 24VAC current on Y1. Pro fix: Ohm outdoor contactor coil (< 4 ohms = shorted) and inspect outdoor thermostat wire jacket..

Manufacturer Family
Google Nest
Control System
Smart Thermostat (24VAC)
Fault Code
E103
LED Blink Sequence
On-screen Nest error E103
Slow / Fast Pulses
1 slow / 3 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code E103 on Google Nest diagnostic LEDs?

Shorted outdoor condenser contactor coil or pinched thermostat wire caused excessive 24VAC current on Y1. Nest Code E103: Overcurrent on Y1 Cooling Wire uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Leave cooling OFF to protect furnace transformer and thermostat base
Licensed Technician

Professional Diagnostic Scope

Ohm outdoor contactor coil (< 4 ohms = shorted) and inspect outdoor thermostat wire jacket.

Google Nest Support — Error E103: Google Nest E103: Shorted outdoor condenser contactor coil or pinched thermostat wire caused excessive 24VAC current on Y1.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code E103 temporarily or alternates with pressure, flame, or limit switch lockouts.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Google Nest #E103

Why does Google Nest blink fault code E103?

Google Nest Smart Thermostat (24VAC) code E103 indicates: Shorted outdoor condenser contactor coil or pinched thermostat wire caused excessive 24VAC current on Y1..

Cadence

What LED timing marks Google Nest code E103?

On Google Nest boards, On-screen Nest error E103 fires 1 slow and 3 fast LED pulses repeatedly.

Check 1

Which external check applies first to Google Nest E103?

First on Google Nest code E103: Leave cooling OFF to protect furnace transformer and thermostat base; secondary check: inspect main air filter restriction.

Manual Ref

What does Google Nest Support — Error E103 document for code E103?

Google Nest E103: Shorted outdoor condenser contactor coil or pinched thermostat wire caused excessive 24VAC current on Y1. — recorded under Google Nest Support — Error E103 for Google Nest Smart Thermostat (24VAC) equipment.

Pro Fix

How do techs repair Google Nest Smart Thermostat (24VAC) fault E103?

Authorized repair on Google Nest code E103: Ohm outdoor contactor coil (< 4 ohms = shorted) and inspect outdoor thermostat wire jacket. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Google Nest code E103?

Relay lockouts protect compressor windings on Google Nest code E103.

Reset

Will flipping the breaker clear Google Nest code E103?

One brief power cycle resets transient Google Nest code E103, while repeat trips need mechanical testing.

Credentials

What license applies to Google Nest Smart Thermostat (24VAC) fault E103?

Licensed mechanical diagnostic credentials apply for Google Nest code E103.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Google Nest Thermostat Wiring, Power & Help Center Error Code Reference — Google Nest Support (Public Docs), Nest Public Help Center (retrieved 2026-11-25)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

Comparable HVAC Climate & Cost Metros