Skip to main content
Lennox · Gas Furnace · Fault Code 273

Lennox Code 273: Flame Lost Mid-Cycle

Burner flame dropped out after initial proving due to dirty flame rod or fluctuating gas supply pressure. Lennox Code 273: Flame Lost Mid-Cycle benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 273: Flame Lost Mid-Cycle across single-family housing. Lennox Diagnostic Codes — 273: Lennox 273: Burner flame dropped out after initial proving due to dirty flame rod or fluctuating gas supply pressure. Pro fix: Monitor DC flame uA and inlet gas line pressure with all household gas loads firing..

Manufacturer Family
Lennox
Control System
Gas Furnace
Fault Code
273
LED Blink Sequence
7-segment LED showing 273
Slow / Fast Pulses
2 slow / 7 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 273 on Lennox diagnostic LEDs?

Burner flame dropped out after initial proving due to dirty flame rod or fluctuating gas supply pressure. Lennox Code 273: Flame Lost Mid-Cycle uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Check if other gas appliances cause pressure drops
  • Do not bypass flame sensing circuits
Licensed Technician

Professional Diagnostic Scope

Monitor DC flame uA and inlet gas line pressure with all household gas loads firing.

Lennox Diagnostic Codes — 273: Lennox 273: Burner flame dropped out after initial proving due to dirty flame rod or fluctuating gas supply pressure.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 273 temporarily or alternates with pressure, flame, or limit switch lockouts.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Lennox #273

Why does Lennox blink fault code 273?

Lennox Gas Furnace code 273 indicates: Burner flame dropped out after initial proving due to dirty flame rod or fluctuating gas supply pressure..

Cadence

What LED timing marks Lennox code 273?

On Lennox boards, 7-segment LED showing 273 fires 2 slow and 7 fast LED pulses repeatedly.

Check 1

Which external check applies first to Lennox 273?

First on Lennox code 273: Check if other gas appliances cause pressure drops; secondary check: Do not bypass flame sensing circuits.

Manual Ref

What does Lennox Diagnostic Codes — 273 document for code 273?

Lennox 273: Burner flame dropped out after initial proving due to dirty flame rod or fluctuating gas supply pressure. — recorded under Lennox Diagnostic Codes — 273 for Lennox Gas Furnace equipment.

Pro Fix

How do techs repair Lennox Gas Furnace fault 273?

Authorized repair on Lennox code 273: Monitor DC flame uA and inlet gas line pressure with all household gas loads firing. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Lennox code 273?

Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 273.

Reset

Will flipping the breaker clear Lennox code 273?

One brief power cycle resets transient Lennox code 273, while repeat trips need mechanical testing.

Credentials

What license applies to Lennox Gas Furnace fault 273?

Licensed mechanical diagnostic credentials apply for Lennox code 273.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Lennox Residential Public Product & Warranty Documentation — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.

Comparable HVAC Climate & Cost Metros