About ThermalSpec
Learn how ThermalSpec compiles ENERGY STAR equipment data, federal SEER2 rules, state utility rates, technician wages, and 5-state licensing registries. About ThermalSpec benchmarks residential systems using Federal AC Minimum set at 13.4 - 14.3 SEER2 and Cleaner Refrigerants set at R-454B or R-32. Values trace to primary federal, state, or OEM filings supporting About ThermalSpec across single-family housing.
- Federal AC Minimum
- 13.4 - 14.3 SEER2
- Cleaner Refrigerants
- R-454B or R-32
- Federal 25C Credit
- Ended Dec 31, 2025
- Covered Homes
- Single-Family & Townhomes
What are the verified details for Mission, Editorial Governance & Residential Boundary?
ThermalSpec operates as a strictly residential US reference directory covering single-family detached homes, duplexes, and townhome heating and cooling systems. Across 15,136 certified ENERGY STAR model combinations organized into 9,520 equipment series pages, every rating traces directly to an individual official record.
Commercial chillers, packaged commercial rooftop units, three-phase industrial plants, and unverified homeowner star ratings are excluded from our indexes. Rather than publishing paid buyer guides or pay-to-rank contractor promotions, ThermalSpec computes peer comparisons and efficiency checks directly from primary federal and state records.
What are the verified details for Five-State Open Contractor Registries & Geographic Hubs?
Contractor lists span Washington L&I, Texas TDLR, Oregon BCD, Connecticut DCP, and New York DOL (6,948 verified active businesses total). Listings are shown only when 8+ active licensed providers exist in official state open data.
All five browser calculators run locally inside your browser using published state electricity rates, natural gas prices, grid emissions, and safety room-size limits.
What are the verified details for ThermalSpec Residential HVAC Coverage Summary?
Category Cohort Counts & Regional Open-Data Distribution Across ThermalSpec. Benchmark rows below summarize verified data specifically for About ThermalSpec.
| Catalog Axis | Indexed Coverage | National Median / Anchor | Update Cadence |
|---|---|---|---|
| Air-Source Heat Pumps | 586 models | 22.0 SEER2 | ENERGY STAR official data |
| Ductless Mini-Splits | 2,096 models | 25.1 SEER2 | ENERGY STAR official data |
| Geothermal Heat Pumps | 1,730 models | 4.5 COP | ENERGY STAR official data |
| Residential Gas Furnaces | 3,740 models | 96.0% AFUE | ENERGY STAR official data |
| Residential Hydronic Boilers | 663 models | 95.0% AFUE | ENERGY STAR official data |
| Room Air Conditioners | 589 models | 15.0 CEER | ENERGY STAR official data |
| Connected Smart Thermostats | 116 models | 0.6 W standby | ENERGY STAR official data |
| State Energy & Labor Atlas | 51 jurisdictions | $29.26/hr US tech pay | EIA / EPA / NOAA / BLS |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
What primary metric defines About ThermalSpec?
About ThermalSpec anchors on Federal AC Minimum at 13.4 - 14.3 SEER2 and Cleaner Refrigerants at R-454B or R-32, sourced from federal datasets and OEM filings.
How are Federal 25C Credit figures verified for About ThermalSpec?
Federal 25C Credit: Ended Dec 31, 2025 and Covered Homes: Single-Family & Townhomes inside About ThermalSpec derive directly from public government data with zero paid boosts.
Who falls outside About ThermalSpec applicability?
About ThermalSpec addresses single-family and townhome systems only; commercial systems and permit sizing need local engineering review.
How do federal regional rules govern About ThermalSpec?
Regional efficiency rules enforce 13.4 North and 14.3 South SEER2 minimums around About ThermalSpec.
Does the under-700 GWP rule affect About ThermalSpec?
2026 residential split equipment covered under About ThermalSpec transitions to R-454B or R-32 with UL 60335-2-40 sensors.
Are 2026 federal tax credits active on About ThermalSpec?
IRS 25C ended Dec 31, 2025 under Public Law 119-21 ($0 in 2026); consult state HEAR programs alongside About ThermalSpec.
What technician license applies to About ThermalSpec work?
Pressurized refrigerant lines and 240V controls noted in About ThermalSpec mandate EPA Section 608 and state mechanical licensing.
How can owners cross-check quotes on About ThermalSpec?
Confirm AHRI reference numbers, <=0.50 in. w.c. static pressure limits, and active board registration when reviewing About ThermalSpec.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- OEWS State Wages & Employment — Heating, Air Conditioning, and Refrigeration Mechanics and Installers (SOC 49-9021) — U.S. Bureau of Labor Statistics (BLS), May 2025 OEWS (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages