Skip to main content
Lennox · Gas Furnace · Fault Code 241

Lennox Code 241: Flame Sensed Without Heat Call

Control board sensed flame current while the gas valve was supposed to be shut off. Lennox Code 241: Flame Sensed Without Heat Call benchmarks residential systems using Manufacturer Family set at Lennox and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Lennox Code 241: Flame Sensed Without Heat Call across single-family housing. Lennox Diagnostic Codes — 241: Lennox 241: Control board sensed flame current while the gas valve was supposed to be shut off. Pro fix: Inspect flame sensor lead for moisture ground and leak-test gas valve..

Manufacturer Family
Lennox
Control System
Gas Furnace
Fault Code
241
LED Blink Sequence
7-segment LED showing 241
Slow / Fast Pulses
2 slow / 4 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 241 on Lennox diagnostic LEDs?

Control board sensed flame current while the gas valve was supposed to be shut off. Lennox Code 241: Flame Sensed Without Heat Call uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Turn thermostat OFF and verify burner is dark through sight glass
  • If burner stays lit, shut gas valve and evacuate
Licensed Technician

Professional Diagnostic Scope

Inspect flame sensor lead for moisture ground and leak-test gas valve.

Lennox Diagnostic Codes — 241: Lennox 241: Control board sensed flame current while the gas valve was supposed to be shut off.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 241 temporarily or alternates with pressure, flame, or limit switch lockouts.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Lennox #241

Why does Lennox blink fault code 241?

Lennox Gas Furnace code 241 indicates: Control board sensed flame current while the gas valve was supposed to be shut off..

Cadence

What LED timing marks Lennox code 241?

On Lennox boards, 7-segment LED showing 241 fires 2 slow and 4 fast LED pulses repeatedly.

Check 1

Which external check applies first to Lennox 241?

First on Lennox code 241: Turn thermostat OFF and verify burner is dark through sight glass; secondary check: If burner stays lit, shut gas valve and evacuate.

Manual Ref

What does Lennox Diagnostic Codes — 241 document for code 241?

Lennox 241: Control board sensed flame current while the gas valve was supposed to be shut off. — recorded under Lennox Diagnostic Codes — 241 for Lennox Gas Furnace equipment.

Pro Fix

How do techs repair Lennox Gas Furnace fault 241?

Authorized repair on Lennox code 241: Inspect flame sensor lead for moisture ground and leak-test gas valve. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Lennox code 241?

Combustion safety lockouts block CO or delayed ignition hazards on Lennox code 241.

Reset

Will flipping the breaker clear Lennox code 241?

One brief power cycle resets transient Lennox code 241, while repeat trips need mechanical testing.

Credentials

What license applies to Lennox Gas Furnace fault 241?

Licensed mechanical diagnostic credentials apply for Lennox code 241.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Lennox Residential Public Product & Warranty Documentation — Lennox International (Public Portal), Lennox Public Portal (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.