Code 31: Pressure Switch Did Not Close or Reopened
Inducer draft pressure switch failed to close within ignition timing or opened during run due to blocked condensate trap, cracked pressure tubing, obstructed flue vent, or failing inducer motor. Code 31: Pressure Switch Did Not Close or Reopened benchmarks residential systems using Manufacturer Family set at Carrier / Bryant / Payne and Control System set at Gas Furnace. Carrier Comfort/Performance Gas Furnace Service Manual — Status Code 31 Table: Code 31: Pressure Switch Did Not Close or Reopened (3 slow + 1 fast flash); verify vent pipe, condensate trap, pressure tubing, and inducer operation. Pro fix: Manometer pressure test (typically -0.40 to -1.20 in. w.c. per model rating plate), pressure switch continuity check, and heat exchanger inspection..
- Manufacturer Family
- Carrier / Bryant / Payne
- Control System
- Gas Furnace
- Fault Code
- 31
- LED Blink Sequence
- 3 slow amber flashes followed by 1 fast amber flash
- Slow / Fast Pulses
- 3 slow / 1 fast
- Control Supply Voltage
- 24 VAC Board / 5 min Breaker Wait
How do you identify fault code 31 on Carrier / Bryant / Payne diagnostic LEDs?
Inducer draft pressure switch failed to close within ignition timing or opened during run due to blocked condensate trap, cracked pressure tubing, obstructed flue vent, or failing inducer motor.
| Diagnostic Field | Measured Cadence | Control Board Meaning |
|---|---|---|
| Slow LED Pulses | 3 x 520 ms amber (2,400 ms) | First digit / slow code cadence |
| Fast LED Pulses | 1 x 200 ms red (380 ms) | Second digit / rapid fault pulses |
| Inducer Vacuum Closure | -0.40 to -1.20 in. w.c. | Model rating-plate pressure switch closing threshold |
| Lockout Escalation Threshold | Code 13 / Retry Cycle | Repeated open-switch events lock ignition timing |
| Total Cycle Period | 3,980 ms | Includes 1,200 ms pause between repeats |
| External Static Ceiling | <= 0.50 in. w.c. | Standard residential furnace/air handler limit |
| 24VAC Control Supply | 24 - 28 VAC nominal | Check transformer output & 3A/5A board fuse |
Which homeowner-safe checks can verify external causes before calling service?
Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.
External Verification Checklist
- Check thermostat heating call and furnace power switch
- Inspect outdoor PVC intake/exhaust terminations for snow, leaves, or nests
- Check condensate drain line for standing water
Professional Diagnostic Scope
Which adjacent OEM fault codes share similar lockout symptoms?
Cross-check related diagnostic LED sequences if cycling power clears code 31 temporarily or alternates with pressure, flame, or limit switch lockouts.
Code 33: Limit Circuit Fault (High-Temp Cutoff)
Code 34: Ignition Proving Failure (Flame Sense)
What field measurements isolate Carrier / Bryant / Payne fault code 31?
Carrier Status Code 31 tracks the draft-proving pressure switch loop during pre-purge and burner ignition. Field isolation separates exhaust vent obstruction, condensate backup in condensing furnaces, and silicone tubing condensation before condemning the switch or inducer housing.
- Connect a calibrated digital manometer with a tee fitting inline on the pressure switch barb to compare live inducer negative draft against the cabinet rating-plate closure value.
- Pull lower condensate trap hoses on 90%+ AFUE Carrier condensing units; trapped water inside the secondary heat-exchanger collector box blocks negative vacuum from reaching the diaphragm.
- Remove both silicone sensing tubes to blow out water droplets and inspect intake/exhaust PVC elbows for nesting bees, leaves, or winter frost caps.
- Examine inducer blower wheel fins and measure motor run amp draw; cracked plastic squirrel-cage wheels spin without developing rated draft vacuum.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Why does Carrier / Bryant / Payne blink fault code 31?
Carrier / Bryant / Payne Gas Furnace code 31 indicates: Inducer draft pressure switch failed to close within ignition timing or opened during run due to blocked condensate trap, cracked .
What LED timing marks Carrier / Bryant / Payne code 31?
On Carrier / Bryant / Payne boards, 3 slow amber flashes followed by 1 fast amber flash fires 3 slow and 1 fast LED pulses repeatedly.
Which external check applies first to Carrier / Bryant / Payne 31?
First on Carrier / Bryant / Payne code 31: Check thermostat heating call and furnace power switch; secondary check: Inspect outdoor PVC intake/exhaust terminations for snow, leaves, or nests.
What does Carrier Comfort/Performance Gas Furnace Service Manual — Status Code 31 Table document for code 31?
Code 31: Pressure Switch Did Not Close or Reopened (3 slow + 1 fast flash); verify vent pipe, condensate trap, pressure tubing, and inducer — recorded under Carrier Comfort/Performance Gas Furnace Service Manual — Status Code 31 Table for Carrier / Bryant / Payne Gas Furnace equipment.
How do techs repair Carrier / Bryant / Payne Gas Furnace fault 31?
Authorized repair on Carrier / Bryant / Payne code 31: Manometer pressure test (typically -0.40 to -1.20 in. w.c. per model rating plate), pressure switch continuity check, and heat exchanger ins (also inspect: Check condensate drain line for standing water).
Why avoid jumping switches on Carrier / Bryant / Payne code 31?
Combustion safety lockouts block CO or delayed ignition hazards on Carrier / Bryant / Payne code 31.
Will flipping the breaker clear Carrier / Bryant / Payne code 31?
One brief power cycle resets transient Carrier / Bryant / Payne code 31, while repeat trips need mechanical testing.
What license applies to Carrier / Bryant / Payne Gas Furnace fault 31?
Licensed mechanical diagnostic credentials apply for Carrier / Bryant / Payne code 31.
Sources
Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.
- Carrier / Bryant / ICP Public Gas Furnace & Heat Pump Installation Literature — Carrier Global (Public Docs), Carrier Residential Public Manuals (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 5 pages.