Rheem / Ruud · Gas Furnace · Fault Code 58

Rheem / Ruud Code 58: Condensate Water Sensor Triggered

Condensate water sensor detected backed-up drain water inside collector box or drain pan. Rheem / Ruud Code 58: Condensate Water Sensor Triggered benchmarks residential systems using Manufacturer Family set at Rheem / Ruud and Control System set at Gas Furnace. Values trace to primary federal, state, or OEM filings supporting Rheem / Ruud Code 58: Condensate Water Sensor Triggered across single-family housing. Rheem Condensing Furnace Table — Code 58: Rheem / Ruud 58: Condensate water sensor detected backed-up drain water inside collector box or drain pan. Pro fix: Flush secondary condensate trap and inspect neutralizer media for blockage..

Manufacturer Family
Rheem / Ruud
Control System
Gas Furnace
Fault Code
58
LED Blink Sequence
Dual 7-segment display showing 58
Slow / Fast Pulses
5 slow / 8 fast
Control Supply Voltage
24 VAC Board / 5 min Breaker Wait

How do you identify fault code 58 on Rheem / Ruud diagnostic LEDs?

Condensate water sensor detected backed-up drain water inside collector box or drain pan. Rheem / Ruud Code 58: Condensate Water Sensor Triggered uses published U.S. Department of Energy, Energy Information Administration, EPA, Bureau of Labor Statistics, or manufacturer technical tables.

Which homeowner-safe checks can verify external causes before calling service?

Homeowners should limit troubleshooting to exterior thermostat settings, return air filter restriction, condensate float switches, and main breaker resets. Never bypass safety interlocks or open gas valves.

Homeowner Safe

External Verification Checklist

  • Check PVC drain outlet outdoors for ice plug or kinked vinyl hose
Licensed Technician

Professional Diagnostic Scope

Flush secondary condensate trap and inspect neutralizer media for blockage.

Rheem Condensing Furnace Table — Code 58: Rheem / Ruud 58: Condensate water sensor detected backed-up drain water inside collector box or drain pan.

Which adjacent OEM fault codes share similar lockout symptoms?

Cross-check related diagnostic LED sequences if cycling power clears code 58 temporarily or alternates with pressure, flame, or limit switch lockouts.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Rheem / Ruud #58

Why does Rheem / Ruud blink fault code 58?

Rheem / Ruud Gas Furnace code 58 indicates: Condensate water sensor detected backed-up drain water inside collector box or drain pan..

Cadence

What LED timing marks Rheem / Ruud code 58?

On Rheem / Ruud boards, Dual 7-segment display showing 58 fires 5 slow and 8 fast LED pulses repeatedly.

Check 1

Which external check applies first to Rheem / Ruud 58?

First on Rheem / Ruud code 58: Check PVC drain outlet outdoors for ice plug or kinked vinyl hose; secondary check: inspect main air filter restriction.

Manual Ref

What does Rheem Condensing Furnace Table — Code 58 document for code 58?

Rheem / Ruud 58: Condensate water sensor detected backed-up drain water inside collector box or drain pan. — recorded under Rheem Condensing Furnace Table — Code 58 for Rheem / Ruud Gas Furnace equipment.

Pro Fix

How do techs repair Rheem / Ruud Gas Furnace fault 58?

Authorized repair on Rheem / Ruud code 58: Flush secondary condensate trap and inspect neutralizer media for blockage. (also inspect: confirm condensate drain trap clearance).

Bypass Risk

Why avoid jumping switches on Rheem / Ruud code 58?

Combustion safety lockouts block CO or delayed ignition hazards on Rheem / Ruud code 58.

Reset

Will flipping the breaker clear Rheem / Ruud code 58?

One brief power cycle resets transient Rheem / Ruud code 58, while repeat trips need mechanical testing.

Credentials

What license applies to Rheem / Ruud Gas Furnace fault 58?

Licensed mechanical diagnostic credentials apply for Rheem / Ruud code 58.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. Rheem / Ruud Residential Heat Pump & Furnace Documentation (B-Terminal Valve) — Rheem Manufacturing, Rheem Residential Specs (retrieved 2026-11-23)
  2. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)