Air-Source Heat Pumps: 2026 SEER2/HSPF2 Specs & Cost Parity
Residential split air-source heat pumps move heat electrically in both directions and must meet a nationwide federal floor of 14.3 SEER2 and 7.5 HSPF2 under federal efficiency rules. ThermalSpec indexes 586 ENERGY STAR certified split heat pump series (median 22.0 SEER2, up to 25.0 SEER2) alongside live 51-state EIA electricity-to-gas parity math.
- Certified HP Series
- 586
- Cohort Median SEER2
- 22.0 SEER2
- DOE Nationwide Floor
- 14.3 SEER2 / 7.5 HSPF2
- Install Labor Span
- $234 - $410
- IRS 25C (2026)
- $0 (Ended Dec 31, 2025)
- A2L Refrigerants
- R-454B / R-32 (<700 GWP)
Which ENERGY STAR split heat pump series meet 2026 Cold Climate and Southwest EER2 rules?
All 586 certified series exceed federal 14.3 SEER2 / 7.5 HSPF2 floors, with inverter models reaching 25.0 SEER2 and retaining 5F capacity for cold-climate installations. Filter certified families below.
| Kenmore (C,H,T)5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 28 |
| Tempstar T5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 28 |
| Kenmore B5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 26 |
| Tempstar B5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 26 |
| Kenmore (C,H,T)5H3V36*K*AAA* (EVD5X60M 3.0T) | 22.0 SEER2 | 9.0 HSPF2 | 35,800 BTU/h | R-454B | 26 |
| Kenmore (C,H,T)5H3V36*K*AAA* (EVM5X60M 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | R-454B | 26 |
| Tempstar T5H3V36*K*AAA* (EVD5X60M 3.0T) | 22.0 SEER2 | 9.0 HSPF2 | 35,800 BTU/h | R-454B | 26 |
| Tempstar T5H3V36*K*AAA* (EVM5X60M 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | R-454B | 26 |
| ACIQ H5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Airquest H5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Arcoaire H5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| BRYANT HEATING AND COOLING SYSTEMS 293VAN036**AA* (CVAVA612 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Carrier 27VNA336A*030* (CVAVA612 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Comfortmaker C5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Day & Night C5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Heil H5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Keeprite C5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 23 |
| Kenmore B5H3V36*K*AAA* (EVD5X60M 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,800 BTU/h | R-454B | 23 |
| Kenmore B5H3V36*K*AAA* (EVM5X60M 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | R-454B | 23 |
| Tempstar B5H3V24*K*AAA* (EVD5X42M 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,400 BTU/h | R-454B | 23 |
| Tempstar B5H3V36*K*AAA* (EVD5X60M 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,800 BTU/h | R-454B | 23 |
| Tempstar B5H3V36*K*AAA* (EVM5X60M 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | R-454B | 23 |
| ACIQ B5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 21 |
| Airquest B5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 21 |
| Arcoaire B5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 21 |
| Comfortmaker B5H3V36*K*AAA* (EVD5X61M 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 36,000 BTU/h | R-454B | 21 |
What are the real disadvantages of a heat pump in cold winters or high electric-rate states?
Air-source heat pumps lose thermal capacity as outdoor temperatures fall below 20F unless rated Cold Climate, triggering expensive backup electric resistance heat strips. In high-electric / cheap-gas states (above US medians of 16.33 c/kWh and $1.45/therm), dual-fuel hybrid setups lower winter bills.
Cooling mode energizes O terminal on Carrier, Trane, Lennox, Goodman, and Bosch; Rheem and Ruud energize B on heating.
Which homeowner profile fits each equipment or service path?
Match your home envelope, utility rate tier, and system age against these four verified decision profiles before signing contractor bids.
Ideal for Moderate Winters & High Gas Prices
Recommended Dual-Fuel Hybrid Setup When
Southwest Cooling Focus (AZ/CA/NM/NV)
Check Panel Capacity Before Switching From Gas
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Residential air-source heat pumps, review 3 important real-world limits and verify local licensing and permit rules directly.
- Standard (non-cold-climate) heat pumps rely heavily on 3.41 BTU/Wh electric resistance backup strips during sub-freezing cold snaps.
- Supply register air feels cooler (90-105F) than gas furnace combustion air (120-140F) even when delivering full room BTU load.
- Miswired 24V O (Carrier/Trane) vs B (Rheem/Ruud) reversing terminals make the system heat in summer and cool in winter.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Run State Tariff Math First | Test exact local EIA $/kWh vs $/therm tariffs inside /tools/heat-pump-vs-gas-furnace/. |
| Check Rebate Rollout Status | IRS 25C ended Dec 31, 2025; verify active state DOE HOMES/HEEHR programs on /rebates/. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Is it okay for a heat pump to run all night in winter?
Yes. Variable-speed inverter heat pumps are engineered to run long, steady low-stage heating cycles overnight in winter rather than short high-watt bursts, maximizing HSPF2 seasonal efficiency.
What is the major disadvantage of a heat pump?
Output drops in sub-freezing weather on non-cold-climate units, backup electric heat strips spike utility bills in high-c/kWh states, and discharge air feels cooler than gas heat.
What is the most common problem with heat pumps?
Stuck or misconfigured 24V O/B reversing valves, iced outdoor coils during defrost sensor failures, and low refrigerant charge causing backup heat strips to run constantly.
What is a better alternative to a standalone heat pump in extreme cold?
A dual-fuel hybrid system pairs an air-source heat pump down to ~25-35F with a 95%+ AFUE condensing gas furnace below the thermal balance point.
How much does a heat pump cost for a 2,000 sq ft home?
Typical 2,000 sq ft homes require ~3.0-4.0 tons (36,000-48,000 BTU/h) and 8-14 technician installation hours ($234 - $410 direct technician wages) plus equipment, A2L RDS coil kit, and permits.
What is a heat pump furnace and how does it work?
A dual-fuel heat pump furnace mounts an electric heat pump A-coil atop a gas furnace, switching automatically at an outdoor thermostat balance temperature.
Why would a heat pump blow cold air in winter?
Low refrigerant charge, failed defrost board, or an inverted 24V O-vs-B reversing valve setting (Rheem/Ruud use B on heat; Carrier/Trane/Goodman use O on cool) causes reversed mode.
What is the legal minimum heat pump efficiency in 2026?
Federal DOE rules require 14.3 SEER2 and 7.5 HSPF2 for residential split heat pumps across all 50 US states and Washington DC.
Sources
Verified numerical figures and rules trace to the 5 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- OEWS State Wages & Employment — Heating, Air Conditioning, and Refrigeration Mechanics and Installers (SOC 49-9021) — U.S. Bureau of Labor Statistics (BLS), May 2025 OEWS (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.