Rated from 3.9 COP to 5.5 COP over 157 certified combinations, WaterFurnace's 74 residential geothermal heat pumps models use Other, R-410A. WaterFurnace Geothermal Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 74 and Rating Span set at 3.9 COP - 5.5 COP. Values trace to primary federal, state, or OEM filings supporting WaterFurnace Geothermal Heat Pumps — ENERGY STAR Certified Models across single-family housing.

Certified Models
74
Rating Span
3.9 COP - 5.5 COP
Capacity Range
Residential capacities
AHRI Combinations
157
Cold Climate Units
0
Category Median
4.5 COP
Residential air handler cabinet with galvanized ductwork and brazed copper piping
WaterFurnace Geothermal Heat Pumps — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

How does WaterFurnace's geothermal heat pumps portfolio cover capacity, refrigerants, and safety?

WaterFurnace covers Residential capacities in geothermal heat pumps across 74 canonical models and 157 AHRI combinations, with 0 Cold Climate certified models and Other, R-410A. Ratings span 3.9 COP up to 5.5 COP (category median 4.5 COP, certified through 2025-02-24). CPSC records show 0 residential HVAC recall notices matching WaterFurnace; check exact AHRI matched pairings on individual model sheets.

Showing 74 entries

Which verified records belong in WaterFurnace Geothermal Heat Pumps — ENERGY STAR Certified Models?

Compare all 74 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 74 ENERGY STAR WaterFurnace Geothermal Heat Pumps Models
WaterFurnace W5SS036BD1 5.1 COP 29.5 EER Open Loop Water-to-Air 4
WaterFurnace W5SZ036BD1 5.1 COP 29.5 EER Open Loop Water-to-Air 4
WaterFurnace W5SS048BD1 5.0 COP 27.6 EER Open Loop Water-to-Air 4
WaterFurnace W5SZ048BD1 5.0 COP 27.6 EER Open Loop Water-to-Air 4
WaterFurnace NDZ026H1 4.8 COP 26.0 EER Open Loop Water-to-Air 4
WaterFurnace NDZ049J1 4.8 COP 27.6 EER Open Loop Water-to-Air 4
WaterFurnace W5SS024BD1 4.8 COP 26.9 EER Open Loop Water-to-Air 4
WaterFurnace W5SZ024BD1 4.8 COP 26.9 EER Open Loop Water-to-Air 4
WaterFurnace W5SS060BD1 4.6 COP 27.1 EER Open Loop Water-to-Air 4
WaterFurnace W5SZ060BD1 4.6 COP 27.1 EER Open Loop Water-to-Air 4
WaterFurnace NDZ064J1 4.5 COP 25.8 EER Open Loop Water-to-Air 4
WaterFurnace W5SS066BD1 4.3 COP 25.1 EER Open Loop Water-to-Air 4
WaterFurnace W5SZ066BD1 4.3 COP 25.1 EER Open Loop Water-to-Air 4
WaterFurnace W7A(V/H)024BV1**2 5.5 COP 47.6 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)036BD1**2 5.4 COP 32.0 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)042BD1**2 5.4 COP 29.7 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)048BD1**2 5.3 COP 28.8 EER Open Loop Water-to-Air 2
WaterFurnace W7A(V/H)036BV1**2 5.3 COP 40.2 EER Open Loop Water-to-Air 2
WaterFurnace W5TV036BD1**2 5.2 COP 30.3 EER Open Loop Water-to-Air 2
WaterFurnace W7A(V/H)048BV1**2 5.2 COP 41.7 EER Open Loop Water-to-Air 2
WaterFurnace W7SZ042BV1**F 5.2 COP 41.4 EER Open Loop Water-to-Air 2
WaterFurnace NVZ033*1 5.1 COP 37.6 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)018BD1**2 5.1 COP 28.3 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)024BD1**2 5.1 COP 28.5 EER Open Loop Water-to-Air 2
WaterFurnace W7A(V/H)060BV1**2 5.1 COP 38.8 EER Open Loop Water-to-Air 2
WaterFurnace W7SZ030BV1**F 5.1 COP 34.9 EER Open Loop Water-to-Air 2
WaterFurnace NSV/NSH022J1*(1,4) 5.0 COP 27.5 EER Open Loop Water-to-Air 2
WaterFurnace NVZ042*1 5.0 COP 40.1 EER Open Loop Water-to-Air 2
WaterFurnace W5TV048BD1**2 5.0 COP 28.6 EER Open Loop Water-to-Air 2
WaterFurnace NSV/NSH036K1*(1,2,4) 4.9 COP 28.8 EER Open Loop Water-to-Air 2
WaterFurnace NSV/NSH042K1*(1,2,4) 4.9 COP 28.1 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)030BD1**2 4.9 COP 31.7 EER Open Loop Water-to-Air 2
WaterFurnace NSV/NSH030J1*(1,4) 4.8 COP 29.5 EER Open Loop Water-to-Air 2
WaterFurnace NVZ050*1 4.8 COP 35.0 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)060BD1**2 4.8 COP 27.8 EER Open Loop Water-to-Air 2
WaterFurnace W7SZ048BV1**F 4.8 COP 35.2 EER Open Loop Water-to-Air 2
WaterFurnace NSV/NSH048K1*(1,2,4) 4.7 COP 25.9 EER Open Loop Water-to-Air 2
WaterFurnace NSV/NSH060K1*(1,4)* 4.7 COP 24.3 EER Open Loop Water-to-Air 2
WaterFurnace W3A(V/H)024BD1**1 4.7 COP 23.3 EER Open Loop Water-to-Air 2
WaterFurnace W5TV060BD1**2 4.7 COP 27.5 EER Open Loop Water-to-Air 2
WaterFurnace SDV038K1*(1,2) 4.6 COP 27.2 EER Open Loop Water-to-Air 2
WaterFurnace SDV049J1*(1,2) 4.6 COP 26.9 EER Open Loop Water-to-Air 2
WaterFurnace SDV064J1*1 4.6 COP 24.1 EER Open Loop Water-to-Air 2
WaterFurnace W5A(V/H)072BD1**2 4.6 COP 26.4 EER Open Loop Water-to-Air 2
WaterFurnace LD(V,H)024A 4.5 COP 22.5 EER Open Loop Water-to-Air 2
WaterFurnace W3A(V/H)036BD1**1 4.5 COP 23.5 EER Open Loop Water-to-Air 2
WaterFurnace W5TV072BD1**2 4.5 COP 26.3 EER Open Loop Water-to-Air 2
WaterFurnace LD(V,H)036A 4.4 COP 22.6 EER Open Loop Water-to-Air 2
WaterFurnace LD(V,H)048A 4.4 COP 24.6 EER Open Loop Water-to-Air 2
WaterFurnace W3A(V/H)048BD1**1 4.4 COP 22.1 EER Open Loop Water-to-Air 2
WaterFurnace SDV072J1*1 4.3 COP 22.8 EER Open Loop Water-to-Air 2
WaterFurnace NDZ072H1 4.2 COP 24.3 EER Open Loop Water-to-Air 2
WaterFurnace NDZ038J1 4.1 COP 23.0 EER Closed Loop Water-to-Air 2
WaterFurnace NSZ036J1* 4.0 COP 20.4 EER Closed Loop Water-to-Air 2
WaterFurnace NSZ048J1* 4.0 COP 18.7 EER Closed Loop Water-to-Air 2
WaterFurnace NSZ030H1* 3.9 COP 18.9 EER Closed Loop Water-to-Air 2
WaterFurnace NSZ042J1* 3.9 COP 19.5 EER Closed Loop Water-to-Air 2
WaterFurnace NSV/NSH030J1*(0,3) 4.7 COP 27.1 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH018J1*(1,4) 4.6 COP 26.0 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH036K1*(0,3) 4.5 COP 24.4 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH060K1*0* 4.4 COP 22.8 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH070J1*(1,4) 4.4 COP 22.9 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH018J1*0 4.3 COP 24.7 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH042K1*(0,3) 4.3 COP 23.3 EER Open Loop Water-to-Air 1
WaterFurnace NVV/NVH060D1*1 4.3 COP 29.6 EER Closed Loop Water-to-Air 1
WaterFurnace W3A(V/H)072BD1**1 4.3 COP 22.4 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH012J1*0 4.2 COP 23.1 EER Open Loop Water-to-Air 1
WaterFurnace NSV/NSH048K1*(0,3) 4.2 COP 22.3 EER Open Loop Water-to-Air 1
WaterFurnace LD(V,H)060B 4.1 COP 23.5 EER Open Loop Water-to-Air 1
WaterFurnace LD(V,H)072A 4.1 COP 23.1 EER Open Loop Water-to-Air 1
WaterFurnace NDV/NDH064K1*(1,4) 4.1 COP 22.9 EER Closed Loop Water-to-Air 1
WaterFurnace W3A(V/H)060BD1**1 4.1 COP 21.2 EER Open Loop Water-to-Air 1
WaterFurnace NSW040*1 3.9 COP 23.4 EER Open Loop Water-to-Water 1
WaterFurnace W5WZ048BE1* 3.9 COP 20.1 EER Open Loop Water-to-Water 1

Which top WaterFurnace geothermal heat pumps anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

WaterFurnace5.1 COP

WaterFurnace W5SS036BD1

29.5 EER | Open Loop Water-to-Air | 4 SKUs

WaterFurnace5.1 COP

WaterFurnace W5SZ036BD1

29.5 EER | Open Loop Water-to-Air | 4 SKUs

WaterFurnace5.0 COP

WaterFurnace W5SS048BD1

27.6 EER | Open Loop Water-to-Air | 4 SKUs

WaterFurnace5.0 COP

WaterFurnace W5SZ048BD1

27.6 EER | Open Loop Water-to-Air | 4 SKUs

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on WaterFurnace Geothermal Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Cohort spread across WaterFurnace: 3.9 COP entry units differ substantially from flagship W5SS036BD1 (5.5 COP).
  • Verify indoor coil AHRI pairing on PD ID 3998658 and 4480329 before pulling state mechanical permits.
  • Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
Homeowner ScenarioRecommended Verification Path
Best fit for WaterFurnaceHomes matched to Residential capacities seeking Other, R-410A compliance and verified ENERGY STAR documentation.
Skip or verify further ifExisting ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

WaterFurnace Peak

Which WaterFurnace geothermal heat pumps model reaches the highest 5.5 COP rating?

W5SS036BD1 tops WaterFurnace's 74 ENERGY STAR geothermal heat pumps models at 5.5 COP across 4 AHRI matches (PD ID 3998658).

Lineup Span

How broad is WaterFurnace's geothermal heat pumps efficiency and BTU range?

WaterFurnace spans 3.9 COP (W5WZ048BE1*) up to 5.5 COP (W5SS036BD1) across Residential capacities, compared with the 4.5 COP category median.

AHRI Pairs

How many AHRI combinations support WaterFurnace geothermal heat pumps?

Current ENERGY STAR datasets document 157 verified indoor-outdoor AHRI combinations distributed across 74 canonical WaterFurnace models.

Cold / Fuel

What refrigerants or fuels power WaterFurnace geothermal heat pumps?

WaterFurnace geothermal heat pumps listings record Other, R-410A, with 0 Cold Climate certified models inside the geothermal heat pumps cohort.

DOE Regions

Where are WaterFurnace geothermal heat pumps compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

Are any CPSC safety recalls linked to WaterFurnace residential HVAC products?

ThermalSpec counts 0 residential HVAC CPSC filings referencing WaterFurnace; verify model serial prefixes at /recalls/ before installation or service.

25C Tax Credit

Do WaterFurnace geothermal heat pumps receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for WaterFurnace in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 3998658.

Sizing Rule

How should homeowners select among WaterFurnace's 74 geothermal heat pumps models?

Match WaterFurnace model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.

Comparable HVAC Climate & Cost Metros