Skip to main content
Arcoaire | Geothermal Heat Pumps

Arcoaire Geothermal Heat Pumps — ENERGY STAR Certified Models

ThermalSpec indexes 64 Arcoaire geothermal heat pumps models spanning Residential capacities, anchored by HS036SR*C******1 (5.1 COP) and HP024V/H/C******1**1 (4.1 COP). Arcoaire Geothermal Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 64 and Rating Span set at 4.1 COP - 5.1 COP.

Certified Models
64
Rating Span
4.1 COP - 5.1 COP
Capacity Range
Residential capacities
AHRI Combinations
106
Cold Climate Units
0
Category Median
4.5 COP
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Arcoaire Geothermal Heat Pumps — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

How does Arcoaire's geothermal heat pumps portfolio cover capacity, refrigerants, and safety?

Arcoaire covers Residential capacities in geothermal heat pumps across 64 canonical models and 106 AHRI combinations, with 0 Cold Climate certified models and Other, R-410A. Ratings span 4.1 COP up to 5.1 COP (category median 4.5 COP, certified through 2025-06-06). CPSC records show 0 residential HVAC recall notices matching Arcoaire; check exact AHRI matched pairings on individual model sheets.

Showing 64 entries

Which verified records belong in Arcoaire Geothermal Heat Pumps — ENERGY STAR Certified Models?

Compare all 64 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 64 ENERGY STAR Arcoaire Geothermal Heat Pumps Models
Arcoaire HS036SR*C******1 4.7 COP 25.5 EER Open Loop Water-to-Air 5
Arcoaire HS024SR*C******1 5.0 COP 27.3 EER Open Loop Water-to-Air 4
Arcoaire HS048SR*C******1 4.7 COP 24.7 EER Open Loop Water-to-Air 4
Arcoaire HS036SR*N******1 4.6 COP 25.0 EER Open Loop Water-to-Air 4
Arcoaire HS024SR*N******1 4.9 COP 26.8 EER Open Loop Water-to-Air 3
Arcoaire HS048SR*N******1 4.6 COP 24.2 EER Open Loop Water-to-Air 3
Arcoaire HS060SR*C******1 4.5 COP 24.6 EER Open Loop Water-to-Air 3
Arcoaire HCR36V/H**C******1 5.1 COP 27.0 EER Open Loop Water-to-Air 2
Arcoaire HCR36V/H**N******1 5.1 COP 26.5 EER Open Loop Water-to-Air 2
Arcoaire HCR48V/H**C******1 5.1 COP 26.3 EER Open Loop Water-to-Air 2
Arcoaire HCR48V/H**N******1 5.1 COP 25.8 EER Open Loop Water-to-Air 2
Arcoaire HCR60V/H**C******1 5.1 COP 27.3 EER Open Loop Water-to-Air 2
Arcoaire HCR60V/H**N******1 5.1 COP 26.8 EER Open Loop Water-to-Air 2
Arcoaire HB030H/V******1**1 5.0 COP 27.0 EER Open Loop Water-to-Air 2
Arcoaire HB042H******1**1 5.0 COP 27.2 EER Open Loop Water-to-Air 2
Arcoaire HCR24H**C******1 4.9 COP 27.8 EER Open Loop Water-to-Air 2
Arcoaire HCR24H**N******1 4.9 COP 27.8 EER Open Loop Water-to-Air 2
Arcoaire HCR24V**C******1 4.9 COP 27.8 EER Open Loop Water-to-Air 2
Arcoaire HCR24V**N******1 4.9 COP 27.8 EER Open Loop Water-to-Air 2
Arcoaire HCR72H**C******1 4.6 COP 24.5 EER Open Loop Water-to-Air 2
Arcoaire HCR72H**N******1 4.6 COP 24.0 EER Open Loop Water-to-Air 2
Arcoaire HCR72V**C******1 4.6 COP 24.5 EER Open Loop Water-to-Air 2
Arcoaire HCR72V**N******1 4.6 COP 24.0 EER Open Loop Water-to-Air 2
Arcoaire HBR42V/H**C******1 4.4 COP 23.5 EER Open Loop Water-to-Air 2
Arcoaire HP048V/H/C******1**1 4.4 COP 21.5 EER Open Loop Water-to-Air 2
Arcoaire HS060SR*N******1 4.4 COP 24.2 EER Open Loop Water-to-Air 2
Arcoaire HS036***N***1**2 4.3 COP 23.1 EER Open Loop Water-to-Air 2
Arcoaire HS072SR*C******1 4.2 COP 23.3 EER Open Loop Water-to-Air 2
Arcoaire HP072V/H/C******1**1 4.1 COP 22.4 EER Open Loop Water-to-Air 2
Arcoaire HS072SR*N******1 4.1 COP 22.9 EER Open Loop Water-to-Air 2
Arcoaire HB036V******1**1 4.9 COP 25.9 EER Open Loop Water-to-Air 1
Arcoaire HB036H******1**1 4.7 COP 24.3 EER Open Loop Water-to-Air 1
Arcoaire HB042V******1**1 4.7 COP 25.6 EER Open Loop Water-to-Air 1
Arcoaire HS036***C***1**2 4.6 COP 24.2 EER Open Loop Water-to-Air 1
Arcoaire HB024H/V******1**1 4.5 COP 27.4 EER Open Loop Water-to-Air 1
Arcoaire HB048H******1**1 4.5 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HS024* 4.5 COP 24.2 EER Open Loop Water-to-Air 1
Arcoaire HB018H******1**2 4.4 COP 24.7 EER Open Loop Water-to-Air 1
Arcoaire HB018V******1**2 4.4 COP 25.3 EER Open Loop Water-to-Air 1
Arcoaire HBR18V/H**C******1 4.4 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HBR18V/H**N******1 4.4 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HBR36V/H**C******1 4.4 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HBR36V/H**N******1 4.4 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HBR42V/H**N******1 4.4 COP 23.5 EER Open Loop Water-to-Air 1
Arcoaire HBR48V/H**C******1 4.4 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HBR48V/H**N******1 4.4 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HBR60V/H**C******1 4.4 COP 23.3 EER Open Loop Water-to-Air 1
Arcoaire HBR60V/H**N******1 4.4 COP 23.3 EER Open Loop Water-to-Air 1
Arcoaire HS024*******1**1 4.4 COP 24.8 EER Open Loop Water-to-Air 1
Arcoaire HS036*******1**2 4.4 COP 23.6 EER Open Loop Water-to-Air 1
Arcoaire HB048V******1**1 4.3 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HBR24V/H**C******1 4.3 COP 25.0 EER Open Loop Water-to-Air 1
Arcoaire HBR24V/H**N******1 4.3 COP 25.0 EER Open Loop Water-to-Air 1
Arcoaire HBR30V/H**C******1 4.3 COP 24.5 EER Open Loop Water-to-Air 1
Arcoaire HBR30V/H**N******1 4.3 COP 24.3 EER Open Loop Water-to-Air 1
Arcoaire HP060H**C***1**1 4.3 COP 24.0 EER Open Loop Water-to-Air 1
Arcoaire HP060V**C***1**1 4.3 COP 22.9 EER Open Loop Water-to-Air 1
Arcoaire HP036V/H/C******1**1 4.2 COP 24.3 EER Open Loop Water-to-Air 1
Arcoaire HP060V/H/C**N***1**1 4.2 COP 23.5 EER Open Loop Water-to-Air 1
Arcoaire HS048*******1**1 4.2 COP 22.4 EER Open Loop Water-to-Air 1
Arcoaire HS060*******1**1 4.2 COP 22.6 EER Open Loop Water-to-Air 1
Arcoaire HW024WR********1 4.2 COP 26.8 EER Open Loop Water-to-Water 1
Arcoaire HW048WR********1 4.2 COP 23.0 EER Open Loop Water-to-Water 1
Arcoaire HP024V/H/C******1**1 4.1 COP 24.8 EER Open Loop Water-to-Air 1

Which top Arcoaire geothermal heat pumps anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

Arcoaire4.7 COP

Arcoaire HS036SR*C******1

25.5 EER | Open Loop Water-to-Air | 5 SKUs

Arcoaire5.0 COP

Arcoaire HS024SR*C******1

27.3 EER | Open Loop Water-to-Air | 4 SKUs

Arcoaire4.7 COP

Arcoaire HS048SR*C******1

24.7 EER | Open Loop Water-to-Air | 4 SKUs

Arcoaire4.6 COP

Arcoaire HS036SR*N******1

25.0 EER | Open Loop Water-to-Air | 4 SKUs

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Arcoaire Geothermal Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Cohort spread across Arcoaire: 4.1 COP entry units differ substantially from flagship HS036SR*C******1 (5.1 COP).
  • Verify indoor coil AHRI pairing on PD ID 4429889 and 3845724 before pulling state mechanical permits.
  • Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
Homeowner ScenarioRecommended Verification Path
Best fit for ArcoaireHomes matched to Residential capacities seeking Other, R-410A compliance and verified ENERGY STAR documentation.
Skip or verify further ifExisting ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Arcoaire Peak

Which Arcoaire geothermal heat pumps model reaches the highest 5.1 COP rating?

HS036SR*C******1 tops Arcoaire's 64 ENERGY STAR geothermal heat pumps models at 5.1 COP across 5 AHRI matches (PD ID 4429889).

Lineup Span

How broad is Arcoaire's geothermal heat pumps efficiency and BTU range?

Arcoaire spans 4.1 COP (HP024V/H/C******1**1) up to 5.1 COP (HS036SR*C******1) across Residential capacities, compared with the 4.5 COP category median.

AHRI Pairs

How many AHRI combinations support Arcoaire geothermal heat pumps?

Current ENERGY STAR datasets document 106 verified indoor-outdoor AHRI combinations distributed across 64 canonical Arcoaire models.

Cold / Fuel

What refrigerants or fuels power Arcoaire geothermal heat pumps?

Arcoaire geothermal heat pumps listings record Other, R-410A, with 0 Cold Climate certified models inside the geothermal heat pumps cohort.

DOE Regions

Where are Arcoaire geothermal heat pumps compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

Are any CPSC safety recalls linked to Arcoaire residential HVAC products?

ThermalSpec counts 0 residential HVAC CPSC filings referencing Arcoaire; verify model serial prefixes at /recalls/ before installation or service.

25C Tax Credit

Do Arcoaire geothermal heat pumps receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Arcoaire in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 4429889.

Sizing Rule

How should homeowners select among Arcoaire's 64 geothermal heat pumps models?

Match Arcoaire model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.