WaterFurnace NSZ042J1* — Geothermal Heat Pump Specifications
WaterFurnace NSZ042J1* (Geothermal Heat Pump, PD ID 2394639) holds 2 ENERGY STAR certified SKUs rated at 3.9 COP — #1,710 of 1,730 (21 tied at floor), -0.60 COP. ENERGY STAR certified residential HVAC model. WaterFurnace NSZ042J1* — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 3.9 COP and Cohort Rank set at #1,710/1,730.
- Heating COP
- 3.9 COP
- Cohort Rank
- #1,710/1,730
- Verified Combos
- 2 SKUs
- Sample PD ID
- 2394639
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | This series |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | Peer range |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does WaterFurnace NSZ042J1* rank across federal compliance and ENERGY STAR cohorts?
WaterFurnace NSZ042J1* ties with 20 peers at 3.90 COP (the cohort floor across 1,730 certified series) for Max COP (-0.60 COP vs 4.50 COP category median) across 2 certified SKU combinations. Closed Loop Water-to-Air unit delivering 3.9 COP and 19.5 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match WaterFurnace in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #1,710 of 1,730 (21 tied at floor) | -0.60 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 19.5 EER | -5.10 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 3.9 / Max EER 19.5 (Closed Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: R-410A |
How much annual energy and operating cost does WaterFurnace NSZ042J1* require?
Modeled utility figures for WaterFurnace NSZ042J1* (WaterFurnace) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max COP ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 3,757 kWh/yr | $614/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 1,846 kWh/yr | $301/yr |
| Total Annual Geothermal Operating Cost | $915/yr | State range: $713 to $2,643 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to WaterFurnace NSZ042J1*?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for WaterFurnace NSZ042J1* (PD ID 2394639).
| NSZ042J1* | Matched AHRI Coil | — | |
| NSZ042J1* | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on WaterFurnace NSZ042J1*, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across WaterFurnace NSZ042J1*: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for WaterFurnace NSZ042J1* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal WaterFurnace NSZ042J1* fit | Single-family replacement needing documented ENERGY STAR PD ID 2394639 with matching indoor air handler. |
| Skip WaterFurnace NSZ042J1* if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare WaterFurnace NSZ042J1* against 5 SERIES NEW050*1* and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does WaterFurnace NSZ042J1* compare with peer Geothermal Heat Pump units?
WaterFurnace NSZ042J1* holds #1,710 of 1,730 (21 tied at floor) out of 1,730 verified geothermal heat pump models (-0.60 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 3.9 COP. Closest same-cohort alternatives include 5 SERIES NEW050*1*.
Where is WaterFurnace NSZ042J1* compliant for 2026 US installation?
WaterFurnace NSZ042J1*: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does WaterFurnace NSZ042J1* model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, WaterFurnace NSZ042J1* runs 3,757 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does WaterFurnace NSZ042J1* cover?
WaterFurnace NSZ042J1* covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does WaterFurnace NSZ042J1* handle extreme weather or cold snaps?
WaterFurnace NSZ042J1* is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern WaterFurnace NSZ042J1*?
WaterFurnace NSZ042J1* specifies R-410A compliance (PD ID 2394639); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in WaterFurnace NSZ042J1* reach 3.9 COP?
Peak 3.9 COP represents the top tested AHRI pairing for WaterFurnace NSZ042J1* (PD ID 2394639); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to WaterFurnace NSZ042J1*?
WaterFurnace NSZ042J1* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include 5 SERIES NEW050*1*.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)