WaterFurnace NVZ042*1 — Geothermal Heat Pump Specifications
WaterFurnace NVZ042*1 (Geothermal Heat Pump, PD ID 2635569) holds 2 ENERGY STAR certified SKUs rated at 5.0 COP — #209 of 1,730 (Top 16.2%, 72 tied), +0.50 COP. ENERGY STAR certified residential HVAC model. WaterFurnace NVZ042*1 — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 5.0 COP and Cohort Rank set at #209/1,730.
- Heating COP
- 5.0 COP
- Cohort Rank
- #209/1,730
- Verified Combos
- 2 SKUs
- Sample PD ID
- 2635569
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 3.9 - 4.1 COP | 228 | Peer range |
| 4.1 - 4.3 COP | 329 | Peer range |
| 4.3 - 4.5 COP | 251 | Peer range |
| 4.5 - 4.7 COP | 296 | Peer range |
| 4.7 - 4.9 COP | 244 | Peer range |
| 4.9 - 5.1 COP | 310 | This series |
| 5.1 - 5.3 COP | 37 | Peer range |
| 5.3 - 5.5 COP | 32 | Peer range |
| 5.5 - 5.7 COP | 3 | Peer range |
How does WaterFurnace NVZ042*1 rank across federal compliance and ENERGY STAR cohorts?
WaterFurnace NVZ042*1 ranks #209 of 1,730 (tied with 71 others at 5.00 COP, top 16.2%, more efficient than 83.8% of certified series) for Max COP (+0.50 COP vs 4.50 COP category median) across 2 certified SKU combinations. Open Loop Water-to-Air unit delivering 5.0 COP and 40.1 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match WaterFurnace in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max COP) | #209 of 1,730 (Top 16.2%, 72 tied) | +0.50 COP vs 4.50 COP category median |
| Closed/Open Loop EER vs Cohort | 40.1 EER | +15.50 EER vs 24.6 EER median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| ENERGY STAR Most Efficient Criteria | MOST EFFICIENT | Max COP 5.0 / Max EER 40.1 (Open Loop Water-to-Air) |
| EPA AIM Act Refrigerant Transition | VERIFY OEM SPEC | Dataset refrigerant: R-410A |
How much annual energy and operating cost does WaterFurnace NVZ042*1 require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, WaterFurnace NVZ042*1 estimates reflect 2 certified SKU combinations tested under PD ID 2635569.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Ground-Source Heating Electricity | 2,931 kWh/yr | $479/yr |
| Ground-Source Cooling Electricity (1,000 hrs) | 898 kWh/yr | $147/yr |
| Total Annual Geothermal Operating Cost | $625/yr | State range: $487 to $1,807 |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to WaterFurnace NVZ042*1?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for WaterFurnace NVZ042*1 (PD ID 2635569).
| NVZ042*1 | Matched AHRI Coil | — | |
| NVZ042*1 | Matched AHRI Coil | — |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on WaterFurnace NVZ042*1, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across WaterFurnace NVZ042*1: headline Max COP reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for WaterFurnace NVZ042*1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal WaterFurnace NVZ042*1 fit | Single-family replacement needing documented ENERGY STAR PD ID 2635569 with matching indoor air handler. |
| Skip WaterFurnace NVZ042*1 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable geothermal heat pump models deliver similar efficiency?
Compare WaterFurnace NVZ042*1 against Day & Night HB030H/V******1**1 and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does WaterFurnace NVZ042*1 compare with peer Geothermal Heat Pump units?
WaterFurnace NVZ042*1 holds #209 of 1,730 (Top 16.2%, 72 tied) out of 1,730 verified geothermal heat pump models (+0.50 COP vs 4.50 COP category median), spanning 2 certified SKUs up to 5.0 COP. Closest same-cohort alternatives include Day & Night HB030H/V******1**1.
Where is WaterFurnace NVZ042*1 compliant for 2026 US installation?
WaterFurnace NVZ042*1: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does WaterFurnace NVZ042*1 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, WaterFurnace NVZ042*1 runs 2,931 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does WaterFurnace NVZ042*1 cover?
WaterFurnace NVZ042*1 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does WaterFurnace NVZ042*1 handle extreme weather or cold snaps?
WaterFurnace NVZ042*1 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern WaterFurnace NVZ042*1?
WaterFurnace NVZ042*1 specifies R-410A compliance (PD ID 2635569); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in WaterFurnace NVZ042*1 reach 5.0 COP?
Peak 5.0 COP represents the top tested AHRI pairing for WaterFurnace NVZ042*1 (PD ID 2635569); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to WaterFurnace NVZ042*1?
WaterFurnace NVZ042*1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Day & Night HB030H/V******1**1.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.