Gradient CCHP11 — Room Air Conditioner Specifications
Gradient CCHP11 (Room Air Conditioner, PD ID 3627050) holds 1 ENERGY STAR certified SKU rated at 16.8 CEER — #9 of 589 (Top 1.7%, 2 tied), +1.80 CEER. ENERGY STAR certified room air conditioner (16.8 CEER). Gradient CCHP11 — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 16.8 CEER and Cohort Rank set at #9/589.
- Cooling CEER
- 16.8 CEER
- Cohort Rank
- #9/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 3627050
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | Peer range |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | This series |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does Gradient CCHP11 rank across federal compliance and ENERGY STAR cohorts?
Gradient CCHP11 ranks #9 of 589 (tied with 1 other at 16.8 CEER, top 1.7%, more efficient than 98.3% of certified series) for Max CEER (+1.80 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 120V chassis (0.8 nominal Tons at 9,300 BTU/h) drawing 415.2 kWh/yr (71% less energy than federal baseline).
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #9 of 589 (Top 1.7%, 2 tied) | +1.80 CEER vs 15.0 CEER category median |
| Energy Margin vs Federal Std | 71% less kWh | +32.0% vs 39% median |
| DOE Annual Test Energy | 415.2 kWh/yr | -116.7 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 120V | Standard 15A/20A 115V household receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does Gradient CCHP11 require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Gradient CCHP11 estimates reflect 1 certified SKU combination tested under PD ID 3627050.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 415.2 kWh/yr | $67.80/yr at US median |
| State Operating Cost Spread | $52.81 (NV) | to $195.89/yr (HI) |
| Energy Saved vs US Federal Baseline | 1016.5 kWh/yr (71%) | $165.99/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Gradient CCHP11?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Gradient CCHP11 (PD ID 3627050).
| CCHP11 | Matched AHRI Coil | 9,300 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Gradient CCHP11, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Gradient CCHP11: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Gradient CCHP11 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Gradient CCHP11 fit | Single-family replacement needing documented ENERGY STAR PD ID 3627050 with matching indoor air handler. |
| Skip Gradient CCHP11 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare Gradient CCHP11 against Kuhl KCVS12B30B and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Gradient CCHP11 compare with peer Room Air Conditioner units?
Gradient CCHP11 holds #9 of 589 (Top 1.7%, 2 tied) out of 589 verified room air conditioner models (+1.80 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 16.8 CEER. Closest same-cohort alternatives include Kuhl KCVS12B30B.
Where is Gradient CCHP11 compliant for 2026 US installation?
Gradient CCHP11: ENERGY STAR certified room air conditioner (16.8 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Gradient CCHP11 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Gradient CCHP11 runs 415.2 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Gradient CCHP11 cover?
Gradient CCHP11 covers 9,300-9,300 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Gradient CCHP11 handle extreme weather or cold snaps?
Gradient CCHP11 is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Gradient CCHP11?
Gradient CCHP11 specifies R-32 compliance (PD ID 3627050); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Gradient CCHP11 reach 16.8 CEER?
Peak 16.8 CEER represents the top tested AHRI pairing for Gradient CCHP11 (PD ID 3627050); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Gradient CCHP11?
Gradient CCHP11 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Kuhl KCVS12B30B.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.