TCL T24WQ2S — Room Air Conditioner Specifications

TCL T24WQ2S (Room Air Conditioner, PD ID 4481488) holds 2 ENERGY STAR certified SKUs rated at 12.7 CEER — #580 of 589 (5 tied, beats 0.8% of peers), -2.30 CEER. ENERGY STAR certified room air conditioner (12.7 CEER). TCL T24WQ2S — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 12.7 CEER and Cohort Rank set at #580/589.

Cooling CEER
12.7 CEER
Cohort Rank
#580/589
Verified Combos
2 SKUs
Sample PD ID
4481488
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
TCL T24WQ2S Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. TCL T24WQ2S sits at 12.7 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 12.7 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14This series
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
TCL T24WQ2S residential equipment inspection. ThermalSpec Editorial Photography

How does TCL T24WQ2S rank across federal compliance and ENERGY STAR cohorts?

TCL T24WQ2S ranks #580 of 589 (tied with 4 others at 12.7 CEER, more efficient than 0.8% of certified series) for Max CEER (-2.30 CEER vs 15.0 CEER category median) across 2 certified SKU combinations. Straddles Window 230V chassis (2.0 nominal Tons at 24,000 BTU/h) drawing 1417.3 kWh/yr (35% less energy than federal baseline).

TCL T24WQ2S Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #580 of 589 (5 tied, beats 0.8% of peers) -2.30 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 35% less kWh -4.0% vs 39% median
DOE Annual Test Energy 1,417.3 kWh/yr +885.4 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 230V Requires dedicated 208/230V NEMA 6-15/6-20 receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does TCL T24WQ2S require?

Annual cost outputs combine TCL T24WQ2S's 12.7 CEER rating and EIA national tariffs across single-family runtime hours.

Annual_USD = 1417.3 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 1417.3 / (1 - 0.35)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption1417.3 kWh/yr$231.45/yr at US median
State Operating Cost Spread$180.28 (NV)to $668.68/yr (HI)
Energy Saved vs US Federal Baseline763.2 kWh/yr (35%)$124.63/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to TCL T24WQ2S?

Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for TCL T24WQ2S (PD ID 4481488).

T24WQ2S Matched AHRI Coil 24,000 BTU/h
T24WQ2S Matched AHRI Coil 24,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on TCL T24WQ2S, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across TCL T24WQ2S: headline Max CEER reflects peak tested matches among 2 SKUs, not lower-rated sizes.
  • Catalog specs for TCL T24WQ2S exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal TCL T24WQ2S fitSingle-family replacement needing documented ENERGY STAR PD ID 4481488 with matching indoor air handler.
Skip TCL T24WQ2S ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare TCL T24WQ2S against Friedrich CCV24A30A and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

Friedrich CCV24A30A

12.7 CEER · 35% less kWh · 24,000 BTU/h

Whirlpool WHAW-241IN

12.7 CEER · 35% less kWh · 24,000 BTU/h

Friedrich KHVM24B34A

12.6 CEER · 35% less kWh · 22,900 BTU/h

Friedrich KHVL28B35A

12.6 CEER · 35% less kWh · 28,200 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does TCL T24WQ2S compare with peer Room Air Conditioner units?

TCL T24WQ2S holds #580 of 589 (5 tied, beats 0.8% of peers) out of 589 verified room air conditioner models (-2.30 CEER vs 15.0 CEER category median), spanning 2 certified SKUs up to 12.7 CEER. Closest same-cohort alternatives include Friedrich CCV24A30A.

DOE Regions

Where is TCL T24WQ2S compliant for 2026 US installation?

TCL T24WQ2S: ENERGY STAR certified room air conditioner (12.7 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does TCL T24WQ2S model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, TCL T24WQ2S runs 1417.3 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does TCL T24WQ2S cover?

TCL T24WQ2S covers 24,000-24,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does TCL T24WQ2S handle extreme weather or cold snaps?

TCL T24WQ2S is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern TCL T24WQ2S?

TCL T24WQ2S specifies R-32 compliance (PD ID 4481488); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 2 certified SKUs in TCL T24WQ2S reach 12.7 CEER?

Peak 12.7 CEER represents the top tested AHRI pairing for TCL T24WQ2S (PD ID 4481488); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to TCL T24WQ2S?

TCL T24WQ2S requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Friedrich CCV24A30A.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros