Day & Night Geothermal Heat Pumps — ENERGY STAR Certified Models
Across ENERGY STAR geothermal heat pumps filings, Day & Night accounts for 64 canonical models (105 AHRI matches) ranging from 4.1 COP up to 5.1 COP (Residential capacities). Day & Night Geothermal Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 64 and Rating Span set at 4.1 COP - 5.1 COP.
- Certified Models
- 64
- Rating Span
- 4.1 COP - 5.1 COP
- Capacity Range
- Residential capacities
- AHRI Combinations
- 105
- Cold Climate Units
- 0
- Category Median
- 4.5 COP
How does Day & Night's geothermal heat pumps portfolio cover capacity, refrigerants, and safety?
Day & Night covers Residential capacities in geothermal heat pumps across 64 canonical models and 105 AHRI combinations, with 0 Cold Climate certified models and Other, R-410A. Ratings span 4.1 COP up to 5.1 COP (category median 4.5 COP, certified through 2025-06-06). CPSC records show 0 residential HVAC recall notices matching Day & Night; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in Day & Night Geothermal Heat Pumps — ENERGY STAR Certified Models?
Compare all 64 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| Day & Night HS036SR*C******1 | 4.7 COP | 25.5 EER | Open Loop Water-to-Air | 5 |
| Day & Night HS024SR*C******1 | 5.0 COP | 27.3 EER | Open Loop Water-to-Air | 4 |
| Day & Night HS048SR*C******1 | 4.7 COP | 24.7 EER | Open Loop Water-to-Air | 4 |
| Day & Night HS036SR*N******1 | 4.6 COP | 25.0 EER | Open Loop Water-to-Air | 4 |
| Day & Night HS024SR*N******1 | 4.9 COP | 26.8 EER | Open Loop Water-to-Air | 3 |
| Day & Night HS048SR*N******1 | 4.6 COP | 24.2 EER | Open Loop Water-to-Air | 3 |
| Day & Night HS060SR*C******1 | 4.5 COP | 24.6 EER | Open Loop Water-to-Air | 3 |
| Day & Night HCR36V/H**C******1 | 5.1 COP | 27.0 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR36V/H**N******1 | 5.1 COP | 26.5 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR48V/H**C******1 | 5.1 COP | 26.3 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR48V/H**N******1 | 5.1 COP | 25.8 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR60V/H**C******1 | 5.1 COP | 27.3 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR60V/H**N******1 | 5.1 COP | 26.8 EER | Open Loop Water-to-Air | 2 |
| Day & Night HB030H/V******1**1 | 5.0 COP | 27.0 EER | Open Loop Water-to-Air | 2 |
| Day & Night HB042H******1**1 | 5.0 COP | 27.2 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR24H**C******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR24H**N******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR24V**C******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR24V**N******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR72H**C******1 | 4.6 COP | 24.5 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR72H**N******1 | 4.6 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR72V**C******1 | 4.6 COP | 24.5 EER | Open Loop Water-to-Air | 2 |
| Day & Night HCR72V**N******1 | 4.6 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| Day & Night HBR18V/H**C******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| Day & Night HBR60V/H**C******1 | 4.4 COP | 23.3 EER | Open Loop Water-to-Air | 2 |
| Day & Night HS060SR*N******1 | 4.4 COP | 24.2 EER | Open Loop Water-to-Air | 2 |
| Day & Night HS036***N***1**2 | 4.3 COP | 23.1 EER | Open Loop Water-to-Air | 2 |
| Day & Night HS072SR*C******1 | 4.2 COP | 23.3 EER | Open Loop Water-to-Air | 2 |
| Day & Night HS072SR*N******1 | 4.1 COP | 22.9 EER | Open Loop Water-to-Air | 2 |
| Day & Night HB036V******1**1 | 4.9 COP | 25.9 EER | Open Loop Water-to-Air | 1 |
| Day & Night HB036H******1**1 | 4.7 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| Day & Night HB042V******1**1 | 4.7 COP | 25.6 EER | Open Loop Water-to-Air | 1 |
| Day & Night HS036***C***1**2 | 4.6 COP | 24.2 EER | Open Loop Water-to-Air | 1 |
| Day & Night HB024H/V******1**1 | 4.5 COP | 27.4 EER | Open Loop Water-to-Air | 1 |
| Day & Night HB048H******1**1 | 4.5 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HS024* | 4.5 COP | 24.2 EER | Open Loop Water-to-Air | 1 |
| Day & Night HB018H******1**2 | 4.4 COP | 24.7 EER | Open Loop Water-to-Air | 1 |
| Day & Night HB018V******1**2 | 4.4 COP | 25.3 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR18V/H**N******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR36V/H**C******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR36V/H**N******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR42V/H**C******1 | 4.4 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR42V/H**N******1 | 4.4 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR48V/H**C******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR48V/H**N******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR60V/H**N******1 | 4.4 COP | 23.3 EER | Open Loop Water-to-Air | 1 |
| Day & Night HP048V/H/C******1**1 | 4.4 COP | 21.5 EER | Open Loop Water-to-Air | 1 |
| Day & Night HS024*******1**1 | 4.4 COP | 24.8 EER | Open Loop Water-to-Air | 1 |
| Day & Night HS036*******1**2 | 4.4 COP | 23.6 EER | Open Loop Water-to-Air | 1 |
| Day & Night HB048V******1**1 | 4.3 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR24V/H**C******1 | 4.3 COP | 25.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR24V/H**N******1 | 4.3 COP | 25.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR30V/H**C******1 | 4.3 COP | 24.5 EER | Open Loop Water-to-Air | 1 |
| Day & Night HBR30V/H**N******1 | 4.3 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| Day & Night HP060H**C***1**1 | 4.3 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Day & Night HP060V**C***1**1 | 4.3 COP | 22.9 EER | Open Loop Water-to-Air | 1 |
| Day & Night HP036V/H/C******1**1 | 4.2 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| Day & Night HP060V/H/C**N***1**1 | 4.2 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| Day & Night HS048*******1**1 | 4.2 COP | 22.4 EER | Open Loop Water-to-Air | 1 |
| Day & Night HS060*******1**1 | 4.2 COP | 22.6 EER | Open Loop Water-to-Air | 1 |
| Day & Night HW024WR********1 | 4.2 COP | 26.8 EER | Open Loop Water-to-Water | 1 |
| Day & Night HW048WR********1 | 4.2 COP | 23.0 EER | Open Loop Water-to-Water | 1 |
| Day & Night HP024V/H/C******1**1 | 4.1 COP | 24.8 EER | Open Loop Water-to-Air | 1 |
| Day & Night HP072V/H/C******1**1 | 4.1 COP | 22.4 EER | Open Loop Water-to-Air | 1 |
Which top Day & Night geothermal heat pumps anchor this lineup?
Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.
Day & Night HS036SR*C******1
Day & Night HS024SR*C******1
Day & Night HS048SR*C******1
Day & Night HS036SR*N******1
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Day & Night Geothermal Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across Day & Night: 4.1 COP entry units differ substantially from flagship HS036SR*C******1 (5.1 COP).
- Verify indoor coil AHRI pairing on PD ID 4429933 and 3845897 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for Day & Night | Homes matched to Residential capacities seeking Other, R-410A compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which Day & Night geothermal heat pumps model reaches the highest 5.1 COP rating?
HS036SR*C******1 tops Day & Night's 64 ENERGY STAR geothermal heat pumps models at 5.1 COP across 5 AHRI matches (PD ID 4429933).
How broad is Day & Night's geothermal heat pumps efficiency and BTU range?
Day & Night spans 4.1 COP (HP072V/H/C******1**1) up to 5.1 COP (HS036SR*C******1) across Residential capacities, compared with the 4.5 COP category median.
How many AHRI combinations support Day & Night geothermal heat pumps?
Current ENERGY STAR datasets document 105 verified indoor-outdoor AHRI combinations distributed across 64 canonical Day & Night models.
What refrigerants or fuels power Day & Night geothermal heat pumps?
Day & Night geothermal heat pumps listings record Other, R-410A, with 0 Cold Climate certified models inside the geothermal heat pumps cohort.
Where are Day & Night geothermal heat pumps compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to Day & Night residential HVAC products?
ThermalSpec counts 0 residential HVAC CPSC filings referencing Day & Night; verify model serial prefixes at /recalls/ before installation or service.
Do Day & Night geothermal heat pumps receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Day & Night in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 4429933.
How should homeowners select among Day & Night's 64 geothermal heat pumps models?
Match Day & Night model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.