ThermalSpec indexes 64 Heil geothermal heat pumps models spanning Residential capacities, anchored by HS036SR*C******1 (5.1 COP) and HP024V/H/C******1**1 (4.1 COP). Heil Geothermal Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 64 and Rating Span set at 4.1 COP - 5.1 COP.
- Certified Models
- 64
- Rating Span
- 4.1 COP - 5.1 COP
- Capacity Range
- Residential capacities
- AHRI Combinations
- 105
- Cold Climate Units
- 0
- Category Median
- 4.5 COP
How does Heil's geothermal heat pumps portfolio cover capacity, refrigerants, and safety?
Heil covers Residential capacities in geothermal heat pumps across 64 canonical models and 105 AHRI combinations, with 0 Cold Climate certified models and Other, R-410A. Ratings span 4.1 COP up to 5.1 COP (category median 4.5 COP, certified through 2025-06-06). CPSC records show 0 residential HVAC recall notices matching Heil; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in Heil Geothermal Heat Pumps — ENERGY STAR Certified Models?
Compare all 64 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| Heil HS036SR*C******1 | 4.7 COP | 25.5 EER | Open Loop Water-to-Air | 5 |
| Heil HS024SR*C******1 | 5.0 COP | 27.3 EER | Open Loop Water-to-Air | 4 |
| Heil HS048SR*C******1 | 4.7 COP | 24.7 EER | Open Loop Water-to-Air | 4 |
| Heil HS036SR*N******1 | 4.6 COP | 25.0 EER | Open Loop Water-to-Air | 4 |
| Heil HS024SR*N******1 | 4.9 COP | 26.8 EER | Open Loop Water-to-Air | 3 |
| Heil HS048SR*N******1 | 4.6 COP | 24.2 EER | Open Loop Water-to-Air | 3 |
| Heil HS060SR*C******1 | 4.5 COP | 24.6 EER | Open Loop Water-to-Air | 3 |
| Heil HCR36V/H**C******1 | 5.1 COP | 27.0 EER | Open Loop Water-to-Air | 2 |
| Heil HCR36V/H**N******1 | 5.1 COP | 26.5 EER | Open Loop Water-to-Air | 2 |
| Heil HCR48V/H**C******1 | 5.1 COP | 26.3 EER | Open Loop Water-to-Air | 2 |
| Heil HCR48V/H**N******1 | 5.1 COP | 25.8 EER | Open Loop Water-to-Air | 2 |
| Heil HCR60V/H**C******1 | 5.1 COP | 27.3 EER | Open Loop Water-to-Air | 2 |
| Heil HCR60V/H**N******1 | 5.1 COP | 26.8 EER | Open Loop Water-to-Air | 2 |
| Heil HB030H/V******1**1 | 5.0 COP | 27.0 EER | Open Loop Water-to-Air | 2 |
| Heil HB042H******1**1 | 5.0 COP | 27.2 EER | Open Loop Water-to-Air | 2 |
| Heil HCR24H**C******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Heil HCR24H**N******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Heil HCR24V**C******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Heil HCR24V**N******1 | 4.9 COP | 27.8 EER | Open Loop Water-to-Air | 2 |
| Heil HCR72H**C******1 | 4.6 COP | 24.5 EER | Open Loop Water-to-Air | 2 |
| Heil HCR72H**N******1 | 4.6 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| Heil HCR72V**C******1 | 4.6 COP | 24.5 EER | Open Loop Water-to-Air | 2 |
| Heil HCR72V**N******1 | 4.6 COP | 24.0 EER | Open Loop Water-to-Air | 2 |
| Heil HP048V/H/C******1**1 | 4.4 COP | 21.5 EER | Open Loop Water-to-Air | 2 |
| Heil HS060SR*N******1 | 4.4 COP | 24.2 EER | Open Loop Water-to-Air | 2 |
| Heil HS036***N***1**2 | 4.3 COP | 23.1 EER | Open Loop Water-to-Air | 2 |
| Heil HS072SR*C******1 | 4.2 COP | 23.3 EER | Open Loop Water-to-Air | 2 |
| Heil HP072V/H/C******1**1 | 4.1 COP | 22.4 EER | Open Loop Water-to-Air | 2 |
| Heil HS072SR*N******1 | 4.1 COP | 22.9 EER | Open Loop Water-to-Air | 2 |
| Heil HB036V******1**1 | 4.9 COP | 25.9 EER | Open Loop Water-to-Air | 1 |
| Heil HB036H******1**1 | 4.7 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| Heil HB042V******1**1 | 4.7 COP | 25.6 EER | Open Loop Water-to-Air | 1 |
| Heil HS036***C***1**2 | 4.6 COP | 24.2 EER | Open Loop Water-to-Air | 1 |
| Heil HB024H/V******1**1 | 4.5 COP | 27.4 EER | Open Loop Water-to-Air | 1 |
| Heil HB048H******1**1 | 4.5 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HS024* | 4.5 COP | 24.2 EER | Open Loop Water-to-Air | 1 |
| Heil HB018H******1**2 | 4.4 COP | 24.7 EER | Open Loop Water-to-Air | 1 |
| Heil HB018V******1**2 | 4.4 COP | 25.3 EER | Open Loop Water-to-Air | 1 |
| Heil HBR18V/H**C******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR18V/H**N******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR36V/H**C******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR36V/H**N******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR42V/H**C******1 | 4.4 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| Heil HBR42V/H**N******1 | 4.4 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| Heil HBR48V/H**C******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR48V/H**N******1 | 4.4 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR60V/H**C******1 | 4.4 COP | 23.3 EER | Open Loop Water-to-Air | 1 |
| Heil HBR60V/H**N******1 | 4.4 COP | 23.3 EER | Open Loop Water-to-Air | 1 |
| Heil HS024*******1**1 | 4.4 COP | 24.8 EER | Open Loop Water-to-Air | 1 |
| Heil HS036*******1**2 | 4.4 COP | 23.6 EER | Open Loop Water-to-Air | 1 |
| Heil HB048V******1**1 | 4.3 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR24V/H**C******1 | 4.3 COP | 25.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR24V/H**N******1 | 4.3 COP | 25.0 EER | Open Loop Water-to-Air | 1 |
| Heil HBR30V/H**C******1 | 4.3 COP | 24.5 EER | Open Loop Water-to-Air | 1 |
| Heil HBR30V/H**N******1 | 4.3 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| Heil HP060H**C***1**1 | 4.3 COP | 24.0 EER | Open Loop Water-to-Air | 1 |
| Heil HP060V**C***1**1 | 4.3 COP | 22.9 EER | Open Loop Water-to-Air | 1 |
| Heil HP036V/H/C******1**1 | 4.2 COP | 24.3 EER | Open Loop Water-to-Air | 1 |
| Heil HP060V/H/C**N***1**1 | 4.2 COP | 23.5 EER | Open Loop Water-to-Air | 1 |
| Heil HS048*******1**1 | 4.2 COP | 22.4 EER | Open Loop Water-to-Air | 1 |
| Heil HS060*******1**1 | 4.2 COP | 22.6 EER | Open Loop Water-to-Air | 1 |
| Heil HW024WR********1 | 4.2 COP | 26.8 EER | Open Loop Water-to-Water | 1 |
| Heil HW048WR********1 | 4.2 COP | 23.0 EER | Open Loop Water-to-Water | 1 |
| Heil HP024V/H/C******1**1 | 4.1 COP | 24.8 EER | Open Loop Water-to-Air | 1 |
Which top Heil geothermal heat pumps anchor this lineup?
Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.
Heil HS036SR*C******1
Heil HS024SR*C******1
Heil HS048SR*C******1
Heil HS036SR*N******1
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Heil Geothermal Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across Heil: 4.1 COP entry units differ substantially from flagship HS036SR*C******1 (5.1 COP).
- Verify indoor coil AHRI pairing on PD ID 4429955 and 3436102 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for Heil | Homes matched to Residential capacities seeking Other, R-410A compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which Heil geothermal heat pumps model reaches the highest 5.1 COP rating?
HS036SR*C******1 tops Heil's 64 ENERGY STAR geothermal heat pumps models at 5.1 COP across 5 AHRI matches (PD ID 4429955).
How broad is Heil's geothermal heat pumps efficiency and BTU range?
Heil spans 4.1 COP (HP024V/H/C******1**1) up to 5.1 COP (HS036SR*C******1) across Residential capacities, compared with the 4.5 COP category median.
How many AHRI combinations support Heil geothermal heat pumps?
Current ENERGY STAR datasets document 105 verified indoor-outdoor AHRI combinations distributed across 64 canonical Heil models.
What refrigerants or fuels power Heil geothermal heat pumps?
Heil geothermal heat pumps listings record Other, R-410A, with 0 Cold Climate certified models inside the geothermal heat pumps cohort.
Where are Heil geothermal heat pumps compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to Heil residential HVAC products?
ThermalSpec counts 0 residential HVAC CPSC filings referencing Heil; verify model serial prefixes at /recalls/ before installation or service.
Do Heil geothermal heat pumps receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Heil in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 4429955.
How should homeowners select among Heil's 64 geothermal heat pumps models?
Match Heil model capacity (Residential capacities) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages