Energy Kinetics EK1RT (Residential Boiler, PD ID 2324980) holds 1 ENERGY STAR certified SKU rated at 91.0% AFUE — #481 of 663 (13 tied, beats 25.6% of peers), -4.00% AFUE. Condensing ENERGY STAR residential boiler (91.0% AFUE; exceeds 84% federal gas boiler floor). Energy Kinetics EK1RT — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 91.0% AFUE and Cohort Rank set at #481/663.

Thermal Efficiency
91.0% AFUE
Cohort Rank
#481/663
Verified Combos
1 SKU
Sample PD ID
2324980
Residential Boiler Efficiency Spread across 663 certified series (87.0 to 97.0% AFUE)
Energy Kinetics EK1RT Residential Boiler Efficiency Spread Distribution Distribution of 663 certified series from 87.0 to 97.0% AFUE. Energy Kinetics EK1RT sits at 91.0% AFUE; typical midpoint is 95.0% AFUE. 148 87.0 0 88.1 22 89.2 13 90.3 3 91.4 4 92.6 19 93.7 402 94.8 52 95.9 Median 95.0% AFUE This model: 91.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.1% AFUE148Peer range
88.1 - 89.2% AFUE0Peer range
89.2 - 90.3% AFUE22Peer range
90.3 - 91.4% AFUE13This series
91.4 - 92.6% AFUE3Peer range
92.6 - 93.7% AFUE4Peer range
93.7 - 94.8% AFUE19Peer range
94.8 - 95.9% AFUE402Peer range
95.9 - 97.0% AFUE52Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Energy Kinetics EK1RT residential equipment inspection. ThermalSpec Editorial Photography

How does Energy Kinetics EK1RT rank across federal compliance and ENERGY STAR cohorts?

Energy Kinetics EK1RT ranks #481 of 663 (tied with 12 others at 91.0% AFUE, more efficient than 25.6% of certified series) for Max AFUE (-4.00% AFUE vs 95.0% AFUE category median) across 1 certified SKU combination. Condensing Oil series at 91.0% AFUE (+11.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2018-08-28.

Energy Kinetics EK1RT Cohort Metrics vs. Residential Boiler Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #481 of 663 (13 tied, beats 25.6% of peers) -4.00% AFUE vs 95.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Residential Boiler Minimum PASS Rated 91.0% AFUE vs 84% federal gas hot-water boiler baseline
Condensing Hydronic Design CONDENSING Extracts latent flue heat below 140F return water temp

How much annual energy and operating cost does Energy Kinetics EK1RT require?

Annual cost outputs combine Energy Kinetics EK1RT's 91.0% AFUE rating and EIA national tariffs across single-family runtime hours.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (91.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)549.5 therms/yr6,429 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$797/yrState range: $407 (ID) to $2,775 (HI)
Fuel Saved vs 80% AFUE Baseline75.5 therms/yr$109/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to Energy Kinetics EK1RT?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Energy Kinetics EK1RT (PD ID 2324980).

EK1RT Matched AHRI Coil — / 91.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Energy Kinetics EK1RT, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Energy Kinetics EK1RT: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Energy Kinetics EK1RT exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Energy Kinetics EK1RT condensing combustion at 91.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal Energy Kinetics EK1RT fitSingle-family replacement needing documented ENERGY STAR PD ID 2324980 with matching indoor air handler.
Skip Energy Kinetics EK1RT ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential boiler models deliver similar efficiency?

Compare Energy Kinetics EK1RT against DeDietrich MCA Pro 35 and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.

DeDietrich MCA Pro 35

91.0% AFUE · Natural Gas · 1 combos

DeDietrich MCA Pro 45

91.0% AFUE · Natural Gas · 1 combos

DeDietrich MCA Pro 65

91.0% AFUE · Natural Gas · 1 combos

Weil-McLain GV90+3

91.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Energy Kinetics EK1RT compare with peer Residential Boiler units?

Energy Kinetics EK1RT holds #481 of 663 (13 tied, beats 25.6% of peers) out of 663 verified residential boiler models (-4.00% AFUE vs 95.0% AFUE category median), spanning 1 certified SKU up to 91.0% AFUE. Closest same-cohort alternatives include DeDietrich MCA Pro 35.

DOE Regions

Where is Energy Kinetics EK1RT compliant for 2026 US installation?

Energy Kinetics EK1RT: Condensing ENERGY STAR residential boiler (91.0% AFUE; exceeds 84% federal gas boiler floor). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Energy Kinetics EK1RT model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Energy Kinetics EK1RT runs 549.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Energy Kinetics EK1RT cover?

Energy Kinetics EK1RT covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Energy Kinetics EK1RT handle extreme weather or cold snaps?

Energy Kinetics EK1RT delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Energy Kinetics EK1RT?

Energy Kinetics EK1RT specifies sealed combustion compliance (PD ID 2324980); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Energy Kinetics EK1RT reach 91.0% AFUE?

Peak 91.0% AFUE represents the top tested AHRI pairing for Energy Kinetics EK1RT (PD ID 2324980); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Energy Kinetics EK1RT?

Energy Kinetics EK1RT requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include DeDietrich MCA Pro 35.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros