Skip to main content
Residential Boiler · DeDietrich · 1 ENERGY STAR Combinations

DeDietrich MCA Pro 45 — Residential Boiler Specifications

DeDietrich MCA Pro 45 (Residential Boiler, PD ID 2221193) holds 1 ENERGY STAR certified SKU rated at 91.0% AFUE — #481 of 663 (13 tied, beats 25.6% of peers), -4.00% AFUE. Condensing ENERGY STAR residential boiler (91.0% AFUE; exceeds 84% federal gas boiler floor). DeDietrich MCA Pro 45 — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 91.0% AFUE and Cohort Rank set at #481/663.

Thermal Efficiency
91.0% AFUE
Cohort Rank
#481/663
Verified Combos
1 SKU
Sample PD ID
2221193
Residential Boiler Efficiency Spread across 663 certified series (87.0 to 97.0% AFUE)
DeDietrich MCA Pro 45 Residential Boiler Efficiency Spread Distribution Distribution of 663 certified series from 87.0 to 97.0% AFUE. DeDietrich MCA Pro 45 sits at 91.0% AFUE; typical midpoint is 95.0% AFUE. 148 87.0 0 88.1 22 89.2 13 90.3 3 91.4 4 92.6 19 93.7 402 94.8 52 95.9 Median 95.0% AFUE This model: 91.0% AFUE (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
87.0 - 88.1% AFUE148Peer range
88.1 - 89.2% AFUE0Peer range
89.2 - 90.3% AFUE22Peer range
90.3 - 91.4% AFUE13This series
91.4 - 92.6% AFUE3Peer range
92.6 - 93.7% AFUE4Peer range
93.7 - 94.8% AFUE19Peer range
94.8 - 95.9% AFUE402Peer range
95.9 - 97.0% AFUE52Peer range
Residential air handler cabinet with galvanized ductwork and brazed copper piping
DeDietrich MCA Pro 45 residential equipment inspection. ThermalSpec Editorial Photography

How does DeDietrich MCA Pro 45 rank across federal compliance and ENERGY STAR cohorts?

DeDietrich MCA Pro 45 ranks #481 of 663 (tied with 12 others at 91.0% AFUE, more efficient than 25.6% of certified series) for Max AFUE (-4.00% AFUE vs 95.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas series at 91.0% AFUE (+11.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2014-02-18.

DeDietrich MCA Pro 45 Cohort Metrics vs. Residential Boiler Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max AFUE) #481 of 663 (13 tied, beats 25.6% of peers) -4.00% AFUE vs 95.0% AFUE category median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal Residential Boiler Minimum PASS Rated 91.0% AFUE vs 84% federal gas hot-water boiler baseline
Condensing Hydronic Design CONDENSING Extracts latent flue heat below 140F return water temp

How much annual energy and operating cost does DeDietrich MCA Pro 45 require?

Annual cost outputs combine DeDietrich MCA Pro 45's 91.0% AFUE rating and EIA national tariffs across single-family runtime hours.

Annual_Therms = (50 MMBtu * 10 therms/MMBtu) / (91.0% / 100)

50 MMBtu heating season at EIA US median $1.45/therm ($15.04/Mcf; range $0.74 ID to $5.05 HI)

Operating BasisEstimated ValueSource Basis
Annual Natural Gas Consumption (50 MMBtu)549.5 therms/yr6,429 lb CO2/yr (11.7 lb/therm)
Estimated Annual Fuel Cost (US Median)$797/yrState range: $407 (ID) to $2,775 (HI)
Fuel Saved vs 80% AFUE Baseline75.5 therms/yr$109/yr saved
80% AFUE B-Vent Chimney vs. 96% AFUE Condensing PVC Two-Pipe
80% AFUE vs 96% AFUE Furnace Heat Exchanger and Venting Architecture Side-by-side schematic comparing an 80% AFUE Type B metal chimney furnace against a 96% AFUE condensing secondary heat exchanger with PVC intake/exhaust and condensate trap. 80% AFUE Non-Condensing Type B Single Primary Exchanger 20% Flue Loss (Hot Chimney) No condensate drain required 96% AFUE Condensing PVC In PVC Out Primary + Secondary SS Coil -16.7% Annual Fuel Burn vs 80% Requires Schedule 40 PVC + Condensate Trap

Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.

Which AHRI certified SKU combinations belong to DeDietrich MCA Pro 45?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for DeDietrich MCA Pro 45 (PD ID 2221193).

MCA Pro 45 Matched AHRI Coil — / 91.0% AFUE

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on DeDietrich MCA Pro 45, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across DeDietrich MCA Pro 45: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for DeDietrich MCA Pro 45 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • DeDietrich MCA Pro 45 condensing combustion at 91.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
Homeowner ScenarioRecommended Verification Path
Ideal DeDietrich MCA Pro 45 fitSingle-family replacement needing documented ENERGY STAR PD ID 2221193 with matching indoor air handler.
Skip DeDietrich MCA Pro 45 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable residential boiler models deliver similar efficiency?

Compare DeDietrich MCA Pro 45 against Energy Kinetics EK1RT and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.

Energy Kinetics EK1RT

91.0% AFUE · Oil · 1 combos

Energy Kinetics Resolute EK1R

91.0% AFUE · Oil · 1 combos

Weil-McLain GV90+3

91.0% AFUE · Natural Gas, Propane Gas · 1 combos

Weil-McLain GV90+4

91.0% AFUE · Natural Gas, Propane Gas · 1 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does DeDietrich MCA Pro 45 compare with peer Residential Boiler units?

DeDietrich MCA Pro 45 holds #481 of 663 (13 tied, beats 25.6% of peers) out of 663 verified residential boiler models (-4.00% AFUE vs 95.0% AFUE category median), spanning 1 certified SKU up to 91.0% AFUE. Closest same-cohort alternatives include Energy Kinetics EK1RT.

DOE Regions

Where is DeDietrich MCA Pro 45 compliant for 2026 US installation?

DeDietrich MCA Pro 45: Condensing ENERGY STAR residential boiler (91.0% AFUE; exceeds 84% federal gas boiler floor). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does DeDietrich MCA Pro 45 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, DeDietrich MCA Pro 45 runs 549.5 therms/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does DeDietrich MCA Pro 45 cover?

DeDietrich MCA Pro 45 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does DeDietrich MCA Pro 45 handle extreme weather or cold snaps?

DeDietrich MCA Pro 45 delivers steady fuel combustion independent of outdoor air temperature.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern DeDietrich MCA Pro 45?

DeDietrich MCA Pro 45 specifies sealed combustion compliance (PD ID 2221193); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in DeDietrich MCA Pro 45 reach 91.0% AFUE?

Peak 91.0% AFUE represents the top tested AHRI pairing for DeDietrich MCA Pro 45 (PD ID 2221193); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to DeDietrich MCA Pro 45?

DeDietrich MCA Pro 45 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Energy Kinetics EK1RT.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 7 pages.

Comparable HVAC Climate & Cost Metros