DeDietrich MCA Pro 65 — Residential Boiler Specifications
DeDietrich MCA Pro 65 (Residential Boiler, PD ID 2221194) holds 1 ENERGY STAR certified SKU rated at 91.0% AFUE — #481 of 663 (13 tied, beats 25.6% of peers), -4.00% AFUE. Condensing ENERGY STAR residential boiler (91.0% AFUE; exceeds 84% federal gas boiler floor). DeDietrich MCA Pro 65 — Residential Boiler Specifications benchmarks residential systems using Thermal Efficiency set at 91.0% AFUE and Cohort Rank set at #481/663.
- Thermal Efficiency
- 91.0% AFUE
- Cohort Rank
- #481/663
- Verified Combos
- 1 SKU
- Sample PD ID
- 2221194
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 87.0 - 88.1% AFUE | 148 | Peer range |
| 88.1 - 89.2% AFUE | 0 | Peer range |
| 89.2 - 90.3% AFUE | 22 | Peer range |
| 90.3 - 91.4% AFUE | 13 | This series |
| 91.4 - 92.6% AFUE | 3 | Peer range |
| 92.6 - 93.7% AFUE | 4 | Peer range |
| 93.7 - 94.8% AFUE | 19 | Peer range |
| 94.8 - 95.9% AFUE | 402 | Peer range |
| 95.9 - 97.0% AFUE | 52 | Peer range |
How does DeDietrich MCA Pro 65 rank across federal compliance and ENERGY STAR cohorts?
DeDietrich MCA Pro 65 ranks #481 of 663 (tied with 12 others at 91.0% AFUE, more efficient than 25.6% of certified series) for Max AFUE (-4.00% AFUE vs 95.0% AFUE category median) across 1 certified SKU combination. Condensing Natural Gas series at 91.0% AFUE (+11.0 pts above federal baseline), needing Schedule 40 PVC venting and condensate drainage with ENERGY STAR qualification dated 2014-02-18.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max AFUE) | #481 of 663 (13 tied, beats 25.6% of peers) | -4.00% AFUE vs 95.0% AFUE category median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal Residential Boiler Minimum | PASS | Rated 91.0% AFUE vs 84% federal gas hot-water boiler baseline |
| Condensing Hydronic Design | CONDENSING | Extracts latent flue heat below 140F return water temp |
How much annual energy and operating cost does DeDietrich MCA Pro 65 require?
Modeled utility figures for DeDietrich MCA Pro 65 (DeDietrich) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max AFUE ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Annual Natural Gas Consumption (50 MMBtu) | 549.5 therms/yr | 6,429 lb CO2/yr (11.7 lb/therm) |
| Estimated Annual Fuel Cost (US Median) | $797/yr | State range: $407 (ID) to $2,775 (HI) |
| Fuel Saved vs 80% AFUE Baseline | 75.5 therms/yr | $109/yr saved |
Condensing 96% AFUE furnaces extract latent flue vapor through a secondary stainless exchanger, requiring Schedule 40 PVC side-wall venting and a condensate trap.
Which AHRI certified SKU combinations belong to DeDietrich MCA Pro 65?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for DeDietrich MCA Pro 65 (PD ID 2221194).
| MCA Pro 65 | Matched AHRI Coil | — | / 91.0% AFUE |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on DeDietrich MCA Pro 65, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across DeDietrich MCA Pro 65: headline Max AFUE reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for DeDietrich MCA Pro 65 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- DeDietrich MCA Pro 65 condensing combustion at 91.0% AFUE requires Schedule 40 PVC venting and freeze-safe condensate traps.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal DeDietrich MCA Pro 65 fit | Single-family replacement needing documented ENERGY STAR PD ID 2221194 with matching indoor air handler. |
| Skip DeDietrich MCA Pro 65 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable residential boiler models deliver similar efficiency?
Compare DeDietrich MCA Pro 65 against Energy Kinetics EK1RT and closely matched residential boiler units sharing similar Max AFUE output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does DeDietrich MCA Pro 65 compare with peer Residential Boiler units?
DeDietrich MCA Pro 65 holds #481 of 663 (13 tied, beats 25.6% of peers) out of 663 verified residential boiler models (-4.00% AFUE vs 95.0% AFUE category median), spanning 1 certified SKU up to 91.0% AFUE. Closest same-cohort alternatives include Energy Kinetics EK1RT.
Where is DeDietrich MCA Pro 65 compliant for 2026 US installation?
DeDietrich MCA Pro 65: Condensing ENERGY STAR residential boiler (91.0% AFUE; exceeds 84% federal gas boiler floor). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does DeDietrich MCA Pro 65 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, DeDietrich MCA Pro 65 runs 549.5 therms/yr across standard cooling/heating hours.
What capacity band and airflow does DeDietrich MCA Pro 65 cover?
DeDietrich MCA Pro 65 covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does DeDietrich MCA Pro 65 handle extreme weather or cold snaps?
DeDietrich MCA Pro 65 delivers steady fuel combustion independent of outdoor air temperature.
What refrigerant class and 2026 tax credit rules govern DeDietrich MCA Pro 65?
DeDietrich MCA Pro 65 specifies sealed combustion compliance (PD ID 2221194); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in DeDietrich MCA Pro 65 reach 91.0% AFUE?
Peak 91.0% AFUE represents the top tested AHRI pairing for DeDietrich MCA Pro 65 (PD ID 2221194); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to DeDietrich MCA Pro 65?
DeDietrich MCA Pro 65 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Energy Kinetics EK1RT.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Boilers Dataset (6rww-hpns) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Natural Gas Prices — Annual Residential Price by State — U.S. Energy Information Administration (EIA), EIA Natural Gas Annual (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 7 pages.