40/5 uF Dual Run Capacitor (370V/440V & +/-6% EIA-456-A)

EIA-456-A +/-6% Band: HERM 37.6-42.4 uF | FAN 4.7-5.3 uF. 440 VAC run capacitors safely upgrade 370 VAC ratings; never install 370 VAC where 440 VAC is specified. Always discharge terminals after isolating 240V power. 40/5 uF Dual Run Capacitor (370V/440V & +/-6% EIA-456-A) benchmarks residential systems using Nameplate Rating set at 40 uF (HERM) / 5 uF (FAN) and Acceptable Tolerance (+/-6%) set at 37.6 to 42.4 uF (HERM) | 4.7 to 5.3 uF (FAN).

Nameplate Rating
40 uF (HERM) / 5 uF (FAN)
Acceptable Tolerance (+/-6%)
37.6 to 42.4 uF (HERM) | 4.7 to 5.3 uF (FAN)
Voltage Substitution
440 VAC replaces 370 VAC safely; reverse prohibited
Safety Gate
240V Stored Charge — Discharge Before Testing
Outdoor AC condenser electrical panel with aluminum dual run capacitor and contactor
40/5 uF Dual Run Capacitor (370V/440V & +/-6% EIA-456-A) ThermalSpec Editorial Photography

What nominal sizing, airflow limits, and service intervals define 40/5 uF Dual Run Capacitor (370V/440V & +/-6% EIA-456-A)?

440 VAC run capacitors safely upgrade 370 VAC ratings; never install 370 VAC where 440 VAC is specified. Always discharge terminals after isolating 240V power. Standard maintenance schedules specify Test annually; replace if outside +/-6% band or domed top to preserve design airflow and blower motor efficiency.

Component ParameterEngineering Value
Nameplate Rating40 uF (HERM) / 5 uF (FAN)
Acceptable Tolerance (+/-6%)37.6 to 42.4 uF (HERM) | 4.7 to 5.3 uF (FAN)
Voltage Substitution440 VAC replaces 370 VAC safely; reverse prohibited
Safety Gate240V Stored Charge — Discharge Before Testing

How does 40/5 uF Dual Run Capacitor (370V/440V & +/-6% EIA-456-A) perform across tonnage ratings and EIA-456-A tolerances?

Pull the 240V disconnect, verify zero VAC across contactor lugs, and discharge terminals through a 20k-ohm resistor prior to multimeter testing.

EIA-456-A +/-6.0% Capacitance Bounds (40/5 uF Dual Run)
Terminal PairNameplate uFMin Acceptable (-6%)Max Acceptable (+6%)
C to HERM (Compressor)40.0 uF37.6 uF42.4 uF
C to FAN (Outdoor Fan)5.0 uF4.7 uF5.3 uF
370 VAC Rated Shell370 VACReplaces 370V ONLYNEVER replace 440V unit
440 VAC Rated Shell440 VACReplaces 370V & 440VUniversal upward safe margin
EIA-456-A Capacitor Microfarad Tolerance Checker
240VAC Condenser Contactor & EIA-456-A Dual Run Capacitor
240VAC Condenser Contactor and Dual Run Capacitor Schematic Wiring block showing 240V disconnect feeding 1-pole vs 2-pole contactor and Common, Herm, and Fan terminals on a dual run capacitor within +/-6% tolerance. 240V Disconnect L1 (120V) L2 (120V) Verify 0 VAC first Contactor (24VAC Coil) 1-Pole: L1 switched 2-Pole: L1+L2 broken 30A / 40A FLA Rated Dual Run Capacitor C HERM FAN EIA-456-A: +/-6.0% uF 440VAC OK for 370VAC

2-pole contactors isolate both L1 and L2 120V legs when idle; a 440VAC capacitor safely replaces 370VAC of matching uF (+/-6% tolerance), never the reverse.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Core Spec

What primary metric defines 40/5 uF Dual Run Capacitor (370V/440V & +/-6%?

40/5 uF Dual Run Capacitor (370V/440V & +/-6% anchors on Nameplate Rating at 40 uF (HERM) / 5 uF (FAN) and Acceptable Tolerance (+/-6%) at 37.6 to 42.4 uF (HERM) | 4.7 to 5.3 uF (FAN), sourced from federal datasets and OEM filings.

Bounds

How are Voltage Substitution figures verified for 40/5 uF Dual Run Capacitor (370V/440V & +/-6%?

Voltage Substitution: 440 VAC replaces 370 VAC safely; reverse prohibited and Safety Gate: 240V Stored Charge — Discharge Before Testing inside 40/5 uF Dual Run Capacitor (370V/440V & +/-6% derive directly from public government data with zero paid boosts.

Exclusions

Who falls outside 40/5 uF Dual Run Capacitor (370V/440V & +/-6% applicability?

40/5 uF Dual Run Capacitor (370V/440V & +/-6% addresses single-family and townhome systems only; commercial systems and permit sizing need local engineering review.

SEER2 Rules

How do federal regional rules govern 40/5 uF Dual Run Capacitor (370V/440V & +/-6%?

Regional efficiency rules enforce 13.4 North and 14.3 South SEER2 minimums around 40/5 uF Dual Run Capacitor (370V/440V & +/-6%.

A2L Spec

Does the under-700 GWP rule affect 40/5 uF Dual Run Capacitor (370V/440V & +/-6%?

2026 residential split equipment covered under 40/5 uF Dual Run Capacitor (370V/440V & +/-6% transitions to R-454B or R-32 with UL 60335-2-40 sensors.

2026 Tax

Are 2026 federal tax credits active on 40/5 uF Dual Run Capacitor (370V/440V & +/-6%?

IRS 25C ended Dec 31, 2025 under Public Law 119-21 ($0 in 2026); consult state HEAR programs alongside 40/5 uF Dual Run Capacitor (370V/440V & +/-6%.

Credentials

What technician license applies to 40/5 uF Dual Run Capacitor (370V/440V & +/-6% work?

Pressurized refrigerant lines and 240V controls noted in 40/5 uF Dual Run Capacitor (370V/440V & +/-6% mandate EPA Section 608 and state mechanical licensing.

Audit

How can owners cross-check quotes on 40/5 uF Dual Run Capacitor (370V/440V & +/-6%?

Confirm AHRI reference numbers, <=0.50 in. w.c. static pressure limits, and active board registration when reviewing 40/5 uF Dual Run Capacitor (370V/440V & +/-6%.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  2. ASHRAE Standards 52.2 (MERV), 62.2 (Residential Ventilation) & 15.2 (A2L Safety) — ASHRAE, ASHRAE 52.2 / 62.2 / 15.2 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 4 pages.

Comparable HVAC Climate & Cost Metros