EIA-456-A Tolerance +/-6% (HERM 32.9-37.1 uF; FAN 4.7-5.3 uF). Always verify power is off at the 240V disconnect and bleed terminals with a 20k-ohm 5W resistor before touching or testing. 35/5 uF Dual Run Capacitor (370V/440V Specs & Test Band) benchmarks residential systems using Capacitance Rating set at 35 uF (HERM) / 5 uF (FAN) and Acceptable Tolerance (+/-6%) set at 32.9 to 37.1 uF (HERM) | 4.7 to 5.3 uF (FAN).

Capacitance Rating
35 uF (HERM) / 5 uF (FAN)
Acceptable Tolerance (+/-6%)
32.9 to 37.1 uF (HERM) | 4.7 to 5.3 uF (FAN)
Frequency
50/60 Hz AC continuous duty
Safety Gate
240V Stored Charge — Discharge Before Testing
Outdoor AC condenser electrical panel with aluminum dual run capacitor and contactor
35/5 uF Dual Run Capacitor (370V/440V Specs & Test Band) ThermalSpec Editorial Photography

What nominal sizing, airflow limits, and service intervals define 35/5 uF Dual Run Capacitor (370V/440V Specs & Test Band)?

Always verify power is off at the 240V disconnect and bleed terminals with a 20k-ohm 5W resistor before touching or testing. Standard maintenance schedules specify Inspect annually; replace outside +/-6% band to preserve design airflow and blower motor efficiency.

Component ParameterEngineering Value
Capacitance Rating35 uF (HERM) / 5 uF (FAN)
Acceptable Tolerance (+/-6%)32.9 to 37.1 uF (HERM) | 4.7 to 5.3 uF (FAN)
Frequency50/60 Hz AC continuous duty
Safety Gate240V Stored Charge — Discharge Before Testing

How does 35/5 uF Dual Run Capacitor (370V/440V Specs & Test Band) perform across tonnage ratings and EIA-456-A tolerances?

Pull the 240V disconnect, verify zero VAC across contactor lugs, and discharge terminals through a 20k-ohm resistor prior to multimeter testing.

EIA-456-A +/-6.0% Capacitance Bounds (35/5 uF Dual Run)
Terminal PairNameplate uFMin Acceptable (-6%)Max Acceptable (+6%)
C to HERM (Compressor)35.0 uF32.9 uF37.1 uF
C to FAN (Outdoor Fan)5.0 uF4.7 uF5.3 uF
370 VAC Rated Shell370 VACReplaces 370V ONLYNEVER replace 440V unit
440 VAC Rated Shell440 VACReplaces 370V & 440VUniversal upward safe margin
EIA-456-A Capacitor Microfarad Tolerance Checker
240VAC Condenser Contactor & EIA-456-A Dual Run Capacitor
240VAC Condenser Contactor and Dual Run Capacitor Schematic Wiring block showing 240V disconnect feeding 1-pole vs 2-pole contactor and Common, Herm, and Fan terminals on a dual run capacitor within +/-6% tolerance. 240V Disconnect L1 (120V) L2 (120V) Verify 0 VAC first Contactor (24VAC Coil) 1-Pole: L1 switched 2-Pole: L1+L2 broken 30A / 40A FLA Rated Dual Run Capacitor C HERM FAN EIA-456-A: +/-6.0% uF 440VAC OK for 370VAC

2-pole contactors isolate both L1 and L2 120V legs when idle; a 440VAC capacitor safely replaces 370VAC of matching uF (+/-6% tolerance), never the reverse.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Core Spec

What primary metric defines 35/5 uF Dual Run Capacitor (370V/440V Specs &?

35/5 uF Dual Run Capacitor (370V/440V Specs & anchors on Capacitance Rating at 35 uF (HERM) / 5 uF (FAN) and Acceptable Tolerance (+/-6%) at 32.9 to 37.1 uF (HERM) | 4.7 to 5.3 uF (FAN), sourced from federal datasets and OEM filings.

Bounds

How are Frequency figures verified for 35/5 uF Dual Run Capacitor (370V/440V Specs &?

Frequency: 50/60 Hz AC continuous duty and Safety Gate: 240V Stored Charge — Discharge Before Testing inside 35/5 uF Dual Run Capacitor (370V/440V Specs & derive directly from public government data with zero paid boosts.

Exclusions

Who falls outside 35/5 uF Dual Run Capacitor (370V/440V Specs & applicability?

35/5 uF Dual Run Capacitor (370V/440V Specs & addresses single-family and townhome systems only; commercial systems and permit sizing need local engineering review.

SEER2 Rules

How do federal regional rules govern 35/5 uF Dual Run Capacitor (370V/440V Specs &?

Regional efficiency rules enforce 13.4 North and 14.3 South SEER2 minimums around 35/5 uF Dual Run Capacitor (370V/440V Specs &.

A2L Spec

Does the under-700 GWP rule affect 35/5 uF Dual Run Capacitor (370V/440V Specs &?

2026 residential split equipment covered under 35/5 uF Dual Run Capacitor (370V/440V Specs & transitions to R-454B or R-32 with UL 60335-2-40 sensors.

2026 Tax

Are 2026 federal tax credits active on 35/5 uF Dual Run Capacitor (370V/440V Specs &?

IRS 25C ended Dec 31, 2025 under Public Law 119-21 ($0 in 2026); consult state HEAR programs alongside 35/5 uF Dual Run Capacitor (370V/440V Specs &.

Credentials

What technician license applies to 35/5 uF Dual Run Capacitor (370V/440V Specs & work?

Pressurized refrigerant lines and 240V controls noted in 35/5 uF Dual Run Capacitor (370V/440V Specs & mandate EPA Section 608 and state mechanical licensing.

Audit

How can owners cross-check quotes on 35/5 uF Dual Run Capacitor (370V/440V Specs &?

Confirm AHRI reference numbers, <=0.50 in. w.c. static pressure limits, and active board registration when reviewing 35/5 uF Dual Run Capacitor (370V/440V Specs &.

Sources

Verified numerical figures and rules trace to the 2 cited federal, state, or OEM documents listed below.

  1. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  2. ASHRAE Standards 52.2 (MERV), 62.2 (Residential Ventilation) & 15.2 (A2L Safety) — ASHRAE, ASHRAE 52.2 / 62.2 / 15.2 (retrieved 2026-11-23)