Vissani VAW08R1AWK — Room Air Conditioner Specifications
Vissani VAW08R1AWK (Room Air Conditioner, PD ID 4724494) holds 1 ENERGY STAR certified SKU rated at 13.7 CEER — #505 of 589 (48 tied, beats 6.3% of peers), -1.30 CEER. ENERGY STAR certified room air conditioner (13.7 CEER). Vissani VAW08R1AWK — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 13.7 CEER and Cohort Rank set at #505/589.
- Cooling CEER
- 13.7 CEER
- Cohort Rank
- #505/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 4724494
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | This series |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | Peer range |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does Vissani VAW08R1AWK rank across federal compliance and ENERGY STAR cohorts?
Vissani VAW08R1AWK ranks #505 of 589 (tied with 47 others at 13.7 CEER, more efficient than 6.3% of certified series) for Max CEER (-1.30 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 115V chassis (0.7 nominal Tons at 7,800 BTU/h) drawing 427.0 kWh/yr (25% less energy than federal baseline).
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #505 of 589 (48 tied, beats 6.3% of peers) | -1.30 CEER vs 15.0 CEER category median |
| Energy Margin vs Federal Std | 25% less kWh | -14.0% vs 39% median |
| DOE Annual Test Energy | 427.0 kWh/yr | -104.9 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 115V | Standard 15A/20A 115V household receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does Vissani VAW08R1AWK require?
Modeled utility figures for Vissani VAW08R1AWK (Vissani) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 427.0 kWh/yr | $69.73/yr at US median |
| State Operating Cost Spread | $54.31 (NV) | to $201.46/yr (HI) |
| Energy Saved vs US Federal Baseline | 142.3 kWh/yr (25%) | $23.24/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Vissani VAW08R1AWK?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Vissani VAW08R1AWK (PD ID 4724494).
| VAW08R1AWK | Matched AHRI Coil | 7,800 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Vissani VAW08R1AWK, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Vissani VAW08R1AWK: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Vissani VAW08R1AWK exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Vissani VAW08R1AWK fit | Single-family replacement needing documented ENERGY STAR PD ID 4724494 with matching indoor air handler. |
| Skip Vissani VAW08R1AWK if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare Vissani VAW08R1AWK against BLACK+DECKER BDM078C and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Vissani VAW08R1AWK compare with peer Room Air Conditioner units?
Vissani VAW08R1AWK holds #505 of 589 (48 tied, beats 6.3% of peers) out of 589 verified room air conditioner models (-1.30 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 13.7 CEER. Closest same-cohort alternatives include BLACK+DECKER BDM078C.
Where is Vissani VAW08R1AWK compliant for 2026 US installation?
Vissani VAW08R1AWK: ENERGY STAR certified room air conditioner (13.7 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Vissani VAW08R1AWK model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Vissani VAW08R1AWK runs 427.0 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Vissani VAW08R1AWK cover?
Vissani VAW08R1AWK covers 7,800-7,800 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Vissani VAW08R1AWK handle extreme weather or cold snaps?
Vissani VAW08R1AWK is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Vissani VAW08R1AWK?
Vissani VAW08R1AWK specifies R-32 compliance (PD ID 4724494); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Vissani VAW08R1AWK reach 13.7 CEER?
Peak 13.7 CEER represents the top tested AHRI pairing for Vissani VAW08R1AWK (PD ID 4724494); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Vissani VAW08R1AWK?
Vissani VAW08R1AWK requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include BLACK+DECKER BDM078C.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.