Whirlpool WHAW061CX — Room Air Conditioner Specifications
Whirlpool WHAW061CX (Room Air Conditioner, PD ID 4713635) holds 1 ENERGY STAR certified SKU rated at 13.7 CEER — #505 of 589 (48 tied, beats 6.3% of peers), -1.30 CEER. ENERGY STAR certified room air conditioner (13.7 CEER). Whirlpool WHAW061CX — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 13.7 CEER and Cohort Rank set at #505/589.
- Cooling CEER
- 13.7 CEER
- Cohort Rank
- #505/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 4713635
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | This series |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | Peer range |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does Whirlpool WHAW061CX rank across federal compliance and ENERGY STAR cohorts?
Whirlpool WHAW061CX ranks #505 of 589 (tied with 47 others at 13.7 CEER, more efficient than 6.3% of certified series) for Max CEER (-1.30 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 115V chassis (0.5 nominal Tons at 6,000 BTU/h) drawing 328.5 kWh/yr (25% less energy than federal baseline).
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #505 of 589 (48 tied, beats 6.3% of peers) | -1.30 CEER vs 15.0 CEER category median |
| Energy Margin vs Federal Std | 25% less kWh | -14.0% vs 39% median |
| DOE Annual Test Energy | 328.5 kWh/yr | -203.4 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 115V | Standard 15A/20A 115V household receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does Whirlpool WHAW061CX require?
Modeled utility figures for Whirlpool WHAW061CX (Whirlpool) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 328.5 kWh/yr | $53.64/yr at US median |
| State Operating Cost Spread | $41.79 (NV) | to $154.99/yr (HI) |
| Energy Saved vs US Federal Baseline | 109.5 kWh/yr (25%) | $17.88/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Whirlpool WHAW061CX?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Whirlpool WHAW061CX (PD ID 4713635).
| WHAW061CX | Matched AHRI Coil | 6,000 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Whirlpool WHAW061CX, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Whirlpool WHAW061CX: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Whirlpool WHAW061CX exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Whirlpool WHAW061CX fit | Single-family replacement needing documented ENERGY STAR PD ID 4713635 with matching indoor air handler. |
| Skip Whirlpool WHAW061CX if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare Whirlpool WHAW061CX against BLACK+DECKER BDM06C and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Whirlpool WHAW061CX compare with peer Room Air Conditioner units?
Whirlpool WHAW061CX holds #505 of 589 (48 tied, beats 6.3% of peers) out of 589 verified room air conditioner models (-1.30 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 13.7 CEER. Closest same-cohort alternatives include BLACK+DECKER BDM06C.
Where is Whirlpool WHAW061CX compliant for 2026 US installation?
Whirlpool WHAW061CX: ENERGY STAR certified room air conditioner (13.7 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Whirlpool WHAW061CX model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Whirlpool WHAW061CX runs 328.5 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Whirlpool WHAW061CX cover?
Whirlpool WHAW061CX covers 6,000-6,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Whirlpool WHAW061CX handle extreme weather or cold snaps?
Whirlpool WHAW061CX is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Whirlpool WHAW061CX?
Whirlpool WHAW061CX specifies R-32 compliance (PD ID 4713635); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Whirlpool WHAW061CX reach 13.7 CEER?
Peak 13.7 CEER represents the top tested AHRI pairing for Whirlpool WHAW061CX (PD ID 4713635); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Whirlpool WHAW061CX?
Whirlpool WHAW061CX requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include BLACK+DECKER BDM06C.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.