Friedrich KHVM24B34A — Room Air Conditioner Specifications
Friedrich KHVM24B34A (Room Air Conditioner, PD ID 3999718) holds 1 ENERGY STAR certified SKU rated at 12.6 CEER — #585 of 589 (3 tied, beats 0.3% of peers), -2.40 CEER. ENERGY STAR certified room air conditioner (12.6 CEER). Friedrich KHVM24B34A — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 12.6 CEER and Cohort Rank set at #585/589.
- Cooling CEER
- 12.6 CEER
- Cohort Rank
- #585/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 3999718
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | This series |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | Peer range |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does Friedrich KHVM24B34A rank across federal compliance and ENERGY STAR cohorts?
Friedrich KHVM24B34A ranks #585 of 589 (tied with 2 others at 12.6 CEER, more efficient than 0.3% of certified series) for Max CEER (-2.40 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 230V chassis (1.9 nominal Tons at 22,900 BTU/h) drawing 1363.1 kWh/yr (35% less energy than federal baseline).
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #585 of 589 (3 tied, beats 0.3% of peers) | -2.40 CEER vs 15.0 CEER category median |
| Energy Margin vs Federal Std | 35% less kWh | -4.0% vs 39% median |
| DOE Annual Test Energy | 1,363.1 kWh/yr | +831.2 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 230V | Requires dedicated 208/230V NEMA 6-15/6-20 receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does Friedrich KHVM24B34A require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Friedrich KHVM24B34A estimates reflect 1 certified SKU combination tested under PD ID 3999718.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 1363.1 kWh/yr | $222.59/yr at US median |
| State Operating Cost Spread | $173.39 (NV) | to $643.11/yr (HI) |
| Energy Saved vs US Federal Baseline | 734.0 kWh/yr (35%) | $119.86/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Friedrich KHVM24B34A?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Friedrich KHVM24B34A (PD ID 3999718).
| KHVM24B34A | Matched AHRI Coil | 22,900 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Friedrich KHVM24B34A, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Friedrich KHVM24B34A: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Friedrich KHVM24B34A exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Friedrich KHVM24B34A fit | Single-family replacement needing documented ENERGY STAR PD ID 3999718 with matching indoor air handler. |
| Skip Friedrich KHVM24B34A if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare Friedrich KHVM24B34A against TCL H24W4KW and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Friedrich KHVM24B34A compare with peer Room Air Conditioner units?
Friedrich KHVM24B34A holds #585 of 589 (3 tied, beats 0.3% of peers) out of 589 verified room air conditioner models (-2.40 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 12.6 CEER. Closest same-cohort alternatives include TCL H24W4KW.
Where is Friedrich KHVM24B34A compliant for 2026 US installation?
Friedrich KHVM24B34A: ENERGY STAR certified room air conditioner (12.6 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Friedrich KHVM24B34A model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Friedrich KHVM24B34A runs 1363.1 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Friedrich KHVM24B34A cover?
Friedrich KHVM24B34A covers 22,900-22,900 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Friedrich KHVM24B34A handle extreme weather or cold snaps?
Friedrich KHVM24B34A is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Friedrich KHVM24B34A?
Friedrich KHVM24B34A specifies R-32 compliance (PD ID 3999718); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Friedrich KHVM24B34A reach 12.6 CEER?
Peak 12.6 CEER represents the top tested AHRI pairing for Friedrich KHVM24B34A (PD ID 3999718); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Friedrich KHVM24B34A?
Friedrich KHVM24B34A requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include TCL H24W4KW.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.