Skip to main content
Room Air Conditioner · TCL · 1 ENERGY STAR Combinations

TCL H10W4KW-CA — Room Air Conditioner Specifications

TCL H10W4KW-CA (Room Air Conditioner, PD ID 4480913) holds 1 ENERGY STAR certified SKU rated at 15.0 CEER — #185 of 589 (195 tied at median), Equal to 15.0 CEER category median. ENERGY STAR certified room air conditioner (15.0 CEER). TCL H10W4KW-CA — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.0 CEER and Cohort Rank set at #185/589.

Cooling CEER
15.0 CEER
Cohort Rank
#185/589
Verified Combos
1 SKU
Sample PD ID
4480913
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
TCL H10W4KW-CA Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. TCL H10W4KW-CA sits at 15.0 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 15.0 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96Peer range
14.5 - 15.1 CEER233This series
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
TCL H10W4KW-CA residential equipment inspection. ThermalSpec Editorial Photography

How does TCL H10W4KW-CA rank across federal compliance and ENERGY STAR cohorts?

TCL H10W4KW-CA ranks #185 of 589 (tied with 194 others at 15.0 CEER, more efficient than 35.7% of certified series) for Max CEER (Equal to 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 115V chassis (0.8 nominal Tons at 10,000 BTU/h) drawing 500.0 kWh/yr (38% less energy than federal baseline). Zero CPSC residential HVAC recall filings match TCL in ThermalSpec's current SaferProducts feed.

TCL H10W4KW-CA Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #185 of 589 (195 tied at median) Equal to 15.0 CEER category median
Energy Margin vs Federal Std 38% less kWh -1.0% vs 39% median
DOE Annual Test Energy 500.0 kWh/yr -31.9 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 115V Standard 15A/20A 115V household receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does TCL H10W4KW-CA require?

Modeled utility figures for TCL H10W4KW-CA (TCL) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.

Annual_USD = 500.0 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 500.0 / (1 - 0.38)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption500.0 kWh/yr$81.65/yr at US median
State Operating Cost Spread$63.60 (NV)to $235.90/yr (HI)
Energy Saved vs US Federal Baseline306.5 kWh/yr (38%)$50.05/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to TCL H10W4KW-CA?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for TCL H10W4KW-CA (PD ID 4480913).

H10W4KW-CA Matched AHRI Coil 10,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on TCL H10W4KW-CA, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across TCL H10W4KW-CA: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for TCL H10W4KW-CA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal TCL H10W4KW-CA fitSingle-family replacement needing documented ENERGY STAR PD ID 4480913 with matching indoor air handler.
Skip TCL H10W4KW-CA ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare TCL H10W4KW-CA against DELLA 048-TL-W10KI and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

DELLA 048-TL-W10KI

15.0 CEER · 38% less kWh · 10,000 BTU/h

Danby DAC100B8IWDB-6

15.0 CEER · 38% less kWh · 10,000 BTU/h

ELEMENT EHWR10BE

15.0 CEER · 38% less kWh · 10,000 BTU/h

Friedrich CCV10A10A

15.0 CEER · 38% less kWh · 10,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does TCL H10W4KW-CA compare with peer Room Air Conditioner units?

TCL H10W4KW-CA holds #185 of 589 (195 tied at median) out of 589 verified room air conditioner models (Equal to 15.0 CEER category median), spanning 1 certified SKU up to 15.0 CEER. Closest same-cohort alternatives include DELLA 048-TL-W10KI.

DOE Regions

Where is TCL H10W4KW-CA compliant for 2026 US installation?

TCL H10W4KW-CA: ENERGY STAR certified room air conditioner (15.0 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does TCL H10W4KW-CA model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, TCL H10W4KW-CA runs 500.0 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does TCL H10W4KW-CA cover?

TCL H10W4KW-CA covers 10,000-10,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does TCL H10W4KW-CA handle extreme weather or cold snaps?

TCL H10W4KW-CA is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern TCL H10W4KW-CA?

TCL H10W4KW-CA specifies R-32 compliance (PD ID 4480913); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in TCL H10W4KW-CA reach 15.0 CEER?

Peak 15.0 CEER represents the top tested AHRI pairing for TCL H10W4KW-CA (PD ID 4480913); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to TCL H10W4KW-CA?

TCL H10W4KW-CA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include DELLA 048-TL-W10KI.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros