TCL H12W4KW — Room Air Conditioner Specifications
TCL H12W4KW (Room Air Conditioner, PD ID 4480914) holds 1 ENERGY STAR certified SKU rated at 15.0 CEER — #185 of 589 (195 tied at median), Equal to 15.0 CEER category median. ENERGY STAR certified room air conditioner (15.0 CEER). TCL H12W4KW — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 15.0 CEER and Cohort Rank set at #185/589.
- Cooling CEER
- 15.0 CEER
- Cohort Rank
- #185/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 4480914
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | Peer range |
| 14.5 - 15.1 CEER | 233 | This series |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does TCL H12W4KW rank across federal compliance and ENERGY STAR cohorts?
TCL H12W4KW ranks #185 of 589 (tied with 194 others at 15.0 CEER, more efficient than 35.7% of certified series) for Max CEER (Equal to 15.0 CEER category median) across 1 certified SKU combination. Straddles Window 115V chassis (1.0 nominal Tons at 12,000 BTU/h) drawing 600.0 kWh/yr (38% less energy than federal baseline). Zero CPSC residential HVAC recall filings match TCL in ThermalSpec's current SaferProducts feed.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #185 of 589 (195 tied at median) | Equal to 15.0 CEER category median |
| Energy Margin vs Federal Std | 38% less kWh | -1.0% vs 39% median |
| DOE Annual Test Energy | 600.0 kWh/yr | +68.1 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 115V | Standard 15A/20A 115V household receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does TCL H12W4KW require?
Annual cost outputs combine TCL H12W4KW's 15.0 CEER rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 600.0 kWh/yr | $97.98/yr at US median |
| State Operating Cost Spread | $76.32 (NV) | to $283.08/yr (HI) |
| Energy Saved vs US Federal Baseline | 367.7 kWh/yr (38%) | $60.05/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to TCL H12W4KW?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for TCL H12W4KW (PD ID 4480914).
| H12W4KW | Matched AHRI Coil | 12,000 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on TCL H12W4KW, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across TCL H12W4KW: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for TCL H12W4KW exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal TCL H12W4KW fit | Single-family replacement needing documented ENERGY STAR PD ID 4480914 with matching indoor air handler. |
| Skip TCL H12W4KW if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare TCL H12W4KW against GE Profile PWDV12W**# and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does TCL H12W4KW compare with peer Room Air Conditioner units?
TCL H12W4KW holds #185 of 589 (195 tied at median) out of 589 verified room air conditioner models (Equal to 15.0 CEER category median), spanning 1 certified SKU up to 15.0 CEER. Closest same-cohort alternatives include GE Profile PWDV12W**#.
Where is TCL H12W4KW compliant for 2026 US installation?
TCL H12W4KW: ENERGY STAR certified room air conditioner (15.0 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does TCL H12W4KW model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, TCL H12W4KW runs 600.0 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does TCL H12W4KW cover?
TCL H12W4KW covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does TCL H12W4KW handle extreme weather or cold snaps?
TCL H12W4KW is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern TCL H12W4KW?
TCL H12W4KW specifies R-32 compliance (PD ID 4480914); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in TCL H12W4KW reach 15.0 CEER?
Peak 15.0 CEER represents the top tested AHRI pairing for TCL H12W4KW (PD ID 4480914); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to TCL H12W4KW?
TCL H12W4KW requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GE Profile PWDV12W**#.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)