Room Air Conditioner · PELONIS · 1 ENERGY STAR Combinations

PELONIS PAT14R2KWT — Room Air Conditioner Specifications

PELONIS PAT14R2KWT (Room Air Conditioner, PD ID 4693776) holds 1 ENERGY STAR certified SKU rated at 13.9 CEER — #462 of 589 (31 tied, beats 16.5% of peers), -1.10 CEER. ENERGY STAR certified room air conditioner (13.9 CEER). PELONIS PAT14R2KWT — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 13.9 CEER and Cohort Rank set at #462/589.

Cooling CEER
13.9 CEER
Cohort Rank
#462/589
Verified Combos
1 SKU
Sample PD ID
4693776
Room Air Conditioner Efficiency Spread across 589 certified series (12.0 to 17.6 CEER)
PELONIS PAT14R2KWT Room Air Conditioner Efficiency Spread Distribution Distribution of 589 certified series from 12.0 to 17.6 CEER. PELONIS PAT14R2KWT sits at 13.9 CEER; typical midpoint is 15.0 CEER. 5 12.0 14 12.6 78 13.2 96 13.9 233 14.5 13 15.1 140 15.7 2 16.4 8 17.0 Median 15.0 CEER This model: 13.9 CEER (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
12.0 - 12.6 CEER5Peer range
12.6 - 13.2 CEER14Peer range
13.2 - 13.9 CEER78Peer range
13.9 - 14.5 CEER96This series
14.5 - 15.1 CEER233Peer range
15.1 - 15.7 CEER13Peer range
15.7 - 16.4 CEER140Peer range
16.4 - 17.0 CEER2Peer range
17.0 - 17.6 CEER8Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
PELONIS PAT14R2KWT residential equipment inspection. ThermalSpec Editorial Photography

How does PELONIS PAT14R2KWT rank across federal compliance and ENERGY STAR cohorts?

PELONIS PAT14R2KWT ranks #462 of 589 (tied with 30 others at 13.9 CEER, more efficient than 16.5% of certified series) for Max CEER (-1.10 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 230V chassis (1.2 nominal Tons at 14,000 BTU/h) drawing 755.4 kWh/yr (49% less energy than federal baseline).

PELONIS PAT14R2KWT Cohort Metrics vs. Room Air Conditioner Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max CEER) #462 of 589 (31 tied, beats 16.5% of peers) -1.10 CEER vs 15.0 CEER category median
Energy Margin vs Federal Std 49% less kWh +10.0% vs 39% median
DOE Annual Test Energy 755.4 kWh/yr +223.5 kWh vs 531.9 kWh median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
2026 Cleaner Refrigerant Rule COMPLIANT A2L Uses R-32 (cleaner low-warming refrigerant standard)
Electrical Supply Circuit 230V Requires dedicated 208/230V NEMA 6-15/6-20 receptacle
Variable-Speed Inverter Compressor INVERTER Variable-Speed

How much annual energy and operating cost does PELONIS PAT14R2KWT require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, PELONIS PAT14R2KWT estimates reflect 1 certified SKU combination tested under PD ID 4693776.

Annual_USD = 755.4 kWh/yr (EPA 750-hr test) * $/kWh | Fed_Baseline_kWh = 755.4 / (1 - 0.49)

EPA ENERGY STAR annual kWh test basis at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
EPA Rated Annual Energy Consumption755.4 kWh/yr$123.36/yr at US median
State Operating Cost Spread$96.09 (NV)to $356.40/yr (HI)
Energy Saved vs US Federal Baseline725.8 kWh/yr (49%)$118.52/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to PELONIS PAT14R2KWT?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for PELONIS PAT14R2KWT (PD ID 4693776).

PAT14R2KWT Matched AHRI Coil 14,000 BTU/h

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on PELONIS PAT14R2KWT, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across PELONIS PAT14R2KWT: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for PELONIS PAT14R2KWT exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal PELONIS PAT14R2KWT fitSingle-family replacement needing documented ENERGY STAR PD ID 4693776 with matching indoor air handler.
Skip PELONIS PAT14R2KWT ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable room air conditioner models deliver similar efficiency?

Compare PELONIS PAT14R2KWT against Brothers 102395 and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.

Brothers 102395

13.9 CEER · 49% less kWh · 14,000 BTU/h

DuraSTAR DRTAC142XVB1

13.9 CEER · 49% less kWh · 14,000 BTU/h

Frigidaire FHTC145WC2

13.9 CEER · 49% less kWh · 14,000 BTU/h

Midea MAT14R2FWTK

13.9 CEER · 49% less kWh · 14,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does PELONIS PAT14R2KWT compare with peer Room Air Conditioner units?

PELONIS PAT14R2KWT holds #462 of 589 (31 tied, beats 16.5% of peers) out of 589 verified room air conditioner models (-1.10 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 13.9 CEER. Closest same-cohort alternatives include Brothers 102395.

DOE Regions

Where is PELONIS PAT14R2KWT compliant for 2026 US installation?

PELONIS PAT14R2KWT: ENERGY STAR certified room air conditioner (13.9 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does PELONIS PAT14R2KWT model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, PELONIS PAT14R2KWT runs 755.4 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does PELONIS PAT14R2KWT cover?

PELONIS PAT14R2KWT covers 14,000-14,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does PELONIS PAT14R2KWT handle extreme weather or cold snaps?

PELONIS PAT14R2KWT is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern PELONIS PAT14R2KWT?

PELONIS PAT14R2KWT specifies R-32 compliance (PD ID 4693776); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in PELONIS PAT14R2KWT reach 13.9 CEER?

Peak 13.9 CEER represents the top tested AHRI pairing for PELONIS PAT14R2KWT (PD ID 4693776); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to PELONIS PAT14R2KWT?

PELONIS PAT14R2KWT requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Brothers 102395.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros