Midea MAT14R2FWTK — Room Air Conditioner Specifications
Midea MAT14R2FWTK (Room Air Conditioner, PD ID 4654984) holds 1 ENERGY STAR certified SKU rated at 13.9 CEER — #462 of 589 (31 tied, beats 16.5% of peers), -1.10 CEER. ENERGY STAR certified room air conditioner (13.9 CEER). Midea MAT14R2FWTK — Room Air Conditioner Specifications benchmarks residential systems using Cooling CEER set at 13.9 CEER and Cohort Rank set at #462/589.
- Cooling CEER
- 13.9 CEER
- Cohort Rank
- #462/589
- Verified Combos
- 1 SKU
- Sample PD ID
- 4654984
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 12.0 - 12.6 CEER | 5 | Peer range |
| 12.6 - 13.2 CEER | 14 | Peer range |
| 13.2 - 13.9 CEER | 78 | Peer range |
| 13.9 - 14.5 CEER | 96 | This series |
| 14.5 - 15.1 CEER | 233 | Peer range |
| 15.1 - 15.7 CEER | 13 | Peer range |
| 15.7 - 16.4 CEER | 140 | Peer range |
| 16.4 - 17.0 CEER | 2 | Peer range |
| 17.0 - 17.6 CEER | 8 | Peer range |
How does Midea MAT14R2FWTK rank across federal compliance and ENERGY STAR cohorts?
Midea MAT14R2FWTK ranks #462 of 589 (tied with 30 others at 13.9 CEER, more efficient than 16.5% of certified series) for Max CEER (-1.10 CEER vs 15.0 CEER category median) across 1 certified SKU combination. Does Not Straddle Window or Windowsill 230V chassis (1.2 nominal Tons at 14,000 BTU/h) drawing 755.4 kWh/yr (49% less energy than federal baseline).
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max CEER) | #462 of 589 (31 tied, beats 16.5% of peers) | -1.10 CEER vs 15.0 CEER category median |
| Energy Margin vs Federal Std | 49% less kWh | +10.0% vs 39% median |
| DOE Annual Test Energy | 755.4 kWh/yr | +223.5 kWh vs 531.9 kWh median |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| 2026 Cleaner Refrigerant Rule | COMPLIANT A2L | Uses R-32 (cleaner low-warming refrigerant standard) |
| Electrical Supply Circuit | 230V | Requires dedicated 208/230V NEMA 6-15/6-20 receptacle |
| Variable-Speed Inverter Compressor | INVERTER | Variable-Speed |
How much annual energy and operating cost does Midea MAT14R2FWTK require?
Modeled utility figures for Midea MAT14R2FWTK (Midea) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max CEER ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| EPA Rated Annual Energy Consumption | 755.4 kWh/yr | $123.36/yr at US median |
| State Operating Cost Spread | $96.09 (NV) | to $356.40/yr (HI) |
| Energy Saved vs US Federal Baseline | 725.8 kWh/yr (49%) | $118.52/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Midea MAT14R2FWTK?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Midea MAT14R2FWTK (PD ID 4654984).
| MAT14R2FWTK | Matched AHRI Coil | 14,000 BTU/h |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Midea MAT14R2FWTK, review 2 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Midea MAT14R2FWTK: headline Max CEER reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for Midea MAT14R2FWTK exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Midea MAT14R2FWTK fit | Single-family replacement needing documented ENERGY STAR PD ID 4654984 with matching indoor air handler. |
| Skip Midea MAT14R2FWTK if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable room air conditioner models deliver similar efficiency?
Compare Midea MAT14R2FWTK against Brothers 102395 and closely matched room air conditioner units sharing similar Max CEER output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Midea MAT14R2FWTK compare with peer Room Air Conditioner units?
Midea MAT14R2FWTK holds #462 of 589 (31 tied, beats 16.5% of peers) out of 589 verified room air conditioner models (-1.10 CEER vs 15.0 CEER category median), spanning 1 certified SKU up to 13.9 CEER. Closest same-cohort alternatives include Brothers 102395.
Where is Midea MAT14R2FWTK compliant for 2026 US installation?
Midea MAT14R2FWTK: ENERGY STAR certified room air conditioner (13.9 CEER). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Midea MAT14R2FWTK model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Midea MAT14R2FWTK runs 755.4 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Midea MAT14R2FWTK cover?
Midea MAT14R2FWTK covers 14,000-14,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Midea MAT14R2FWTK handle extreme weather or cold snaps?
Midea MAT14R2FWTK is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern Midea MAT14R2FWTK?
Midea MAT14R2FWTK specifies R-32 compliance (PD ID 4654984); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in Midea MAT14R2FWTK reach 13.9 CEER?
Peak 13.9 CEER represents the top tested AHRI pairing for Midea MAT14R2FWTK (PD ID 4654984); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Midea MAT14R2FWTK?
Midea MAT14R2FWTK requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Brothers 102395.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Room Air Conditioners Dataset (5xn2-dv4h) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.