VENTAGEN TSVH12HEI2N24O454 — Mini-Split Heat Pump Specifications
VENTAGEN TSVH12HEI2N24O454 (Mini-Split Heat Pump, PD ID 4577200) holds 1 ENERGY STAR certified SKU rated at 25.0 SEER2 — #1,069 of 2,096 (311 tied, beats 34.2% of peers), -0.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). VENTAGEN TSVH12HEI2N24O454 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.0 SEER2 and Heating Rating set at 10.5 HSPF2.
- Max SEER2
- 25.0 SEER2
- Heating Rating
- 10.5 HSPF2
- Heating COP
- 1.8 COP
- Cohort Rank
- #1,069/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4577200
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | This series |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does VENTAGEN TSVH12HEI2N24O454 rank across federal compliance and ENERGY STAR cohorts?
VENTAGEN TSVH12HEI2N24O454 ranks #1,069 of 2,096 (tied with 310 others at 25.0 SEER2, more efficient than 34.2% of certified series) for Max SEER2 (-0.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (100.0% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,069 of 2,096 (311 tied, beats 34.2% of peers) | -0.10 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.5 HSPF2 | Equal to 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 14.0 EER2 | Equal to 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 100.0% of 47F rating | 5F COP 1.8 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.0 SEER2 / 10.5 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 14.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does VENTAGEN TSVH12HEI2N24O454 require?
Annual cost outputs combine VENTAGEN TSVH12HEI2N24O454's 25.0 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 480 kWh/yr | $78/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,857 kWh/yr | $467/yr at US median |
| Combined Annual Electricity Cost | $545/yr | State range: $424 (NV) to $1,574 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,502 kWh/yr | $245/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to VENTAGEN TSVH12HEI2N24O454?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for VENTAGEN TSVH12HEI2N24O454 (PD ID 4577200).
| TSVH12HEI2N24O454 | TSVH12HEI2N24I454 | 12,000 BTU/h | 25.0 SEER2 / 10.5 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on VENTAGEN TSVH12HEI2N24O454, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across VENTAGEN TSVH12HEI2N24O454: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for VENTAGEN TSVH12HEI2N24O454 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- VENTAGEN TSVH12HEI2N24O454 uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal VENTAGEN TSVH12HEI2N24O454 fit | Single-family replacement needing documented ENERGY STAR PD ID 4577200 with matching indoor air handler. |
| Skip VENTAGEN TSVH12HEI2N24O454 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare VENTAGEN TSVH12HEI2N24O454 against Air Tempo ATCB12K454B-O* and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does VENTAGEN TSVH12HEI2N24O454 compare with peer Mini-Split Heat Pump units?
VENTAGEN TSVH12HEI2N24O454 holds #1,069 of 2,096 (311 tied, beats 34.2% of peers) out of 2,096 verified mini-split heat pump models (-0.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.0 SEER2. Closest same-cohort alternatives include Air Tempo ATCB12K454B-O*.
Where is VENTAGEN TSVH12HEI2N24O454 compliant for 2026 US installation?
VENTAGEN TSVH12HEI2N24O454: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does VENTAGEN TSVH12HEI2N24O454 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, VENTAGEN TSVH12HEI2N24O454 runs 480 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does VENTAGEN TSVH12HEI2N24O454 cover?
VENTAGEN TSVH12HEI2N24O454 covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does VENTAGEN TSVH12HEI2N24O454 handle extreme weather or cold snaps?
Yes, VENTAGEN TSVH12HEI2N24O454 carries ENERGY STAR Cold Climate certification (100.0% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern VENTAGEN TSVH12HEI2N24O454?
VENTAGEN TSVH12HEI2N24O454 specifies R-454B compliance (PD ID 4577200); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in VENTAGEN TSVH12HEI2N24O454 reach 25.0 SEER2?
Peak 25.0 SEER2 represents the top tested AHRI pairing for VENTAGEN TSVH12HEI2N24O454 (PD ID 4577200); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to VENTAGEN TSVH12HEI2N24O454?
VENTAGEN TSVH12HEI2N24O454 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Air Tempo ATCB12K454B-O*.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.