Skip to main content
Mini-Split Heat Pump · Air Tempo · 1 ENERGY STAR Combinations

Air Tempo ATCB12K454B-O* — Mini-Split Heat Pump Specifications

Air Tempo ATCB12K454B-O* (Mini-Split Heat Pump, PD ID 4680119) holds 1 ENERGY STAR certified SKU rated at 25.0 SEER2 — #1,069 of 2,096 (311 tied, beats 34.2% of peers), -0.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Air Tempo ATCB12K454B-O* — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 25.0 SEER2 and Heating Rating set at 10.5 HSPF2.

Max SEER2
25.0 SEER2
Heating Rating
10.5 HSPF2
Heating COP
1.8 COP
Cohort Rank
#1,069/2,096
Verified Combos
1 SKU
Sample PD ID
4680119
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
Air Tempo ATCB12K454B-O* Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. Air Tempo ATCB12K454B-O* sits at 25.0 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 25.0 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717Peer range
25.0 - 26.2 SEER2785This series
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Air Tempo ATCB12K454B-O* residential equipment inspection. ThermalSpec Editorial Photography

How does Air Tempo ATCB12K454B-O* rank across federal compliance and ENERGY STAR cohorts?

Air Tempo ATCB12K454B-O* ranks #1,069 of 2,096 (tied with 310 others at 25.0 SEER2, more efficient than 34.2% of certified series) for Max SEER2 (-0.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (100.0% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

Air Tempo ATCB12K454B-O* Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #1,069 of 2,096 (311 tied, beats 34.2% of peers) -0.10 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 10.5 HSPF2 Equal to 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 14.0 EER2 Equal to 14.0 EER2 median
5F Cold-Weather Capacity Retention 100.0% of 47F rating 5F COP 1.8
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 25.0 SEER2 / 10.5 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 14.0 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does Air Tempo ATCB12K454B-O* require?

Annual cost outputs combine Air Tempo ATCB12K454B-O*'s 25.0 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (12,000 BTU/h * 1,000 hrs / 25.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 10.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy480 kWh/yr$78/yr at US median
Estimated Annual Heating Energy (30 MMBtu)2,857 kWh/yr$467/yr at US median
Combined Annual Electricity Cost$545/yrState range: $424 (NV) to $1,574 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,502 kWh/yr$245/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Air Tempo ATCB12K454B-O*?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Air Tempo ATCB12K454B-O* (PD ID 4680119).

ATCB12K454B-O* ATCB12K454B-I* 12,000 BTU/h 25.0 SEER2 / 10.5 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Air Tempo ATCB12K454B-O*, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Air Tempo ATCB12K454B-O*: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Air Tempo ATCB12K454B-O* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Air Tempo ATCB12K454B-O* uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal Air Tempo ATCB12K454B-O* fitSingle-family replacement needing documented ENERGY STAR PD ID 4680119 with matching indoor air handler.
Skip Air Tempo ATCB12K454B-O* ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare Air Tempo ATCB12K454B-O* against ADB DBED-T12IH3A1-E* and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

ADB DBED-T12IH3A1-E*

25.0 SEER2 · 10.0 HSPF2 · 12,000 BTU/h

ADB DBED-T12IH3A2-E*

25.0 SEER2 · 10.0 HSPF2 · 12,000 BTU/h

AI AIR CONDITIONING AO25-12N2-M1H

25.0 SEER2 · 10.5 HSPF2 · 12,000 BTU/h

AUX AMAR12HP115V1CO

25.0 SEER2 · 10.5 HSPF2 · 12,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Air Tempo ATCB12K454B-O* compare with peer Mini-Split Heat Pump units?

Air Tempo ATCB12K454B-O* holds #1,069 of 2,096 (311 tied, beats 34.2% of peers) out of 2,096 verified mini-split heat pump models (-0.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 25.0 SEER2. Closest same-cohort alternatives include ADB DBED-T12IH3A1-E*.

DOE Regions

Where is Air Tempo ATCB12K454B-O* compliant for 2026 US installation?

Air Tempo ATCB12K454B-O*: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Air Tempo ATCB12K454B-O* model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Air Tempo ATCB12K454B-O* runs 480 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Air Tempo ATCB12K454B-O* cover?

Air Tempo ATCB12K454B-O* covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Air Tempo ATCB12K454B-O* handle extreme weather or cold snaps?

Yes, Air Tempo ATCB12K454B-O* carries ENERGY STAR Cold Climate certification (100.0% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Air Tempo ATCB12K454B-O*?

Air Tempo ATCB12K454B-O* specifies R-454B compliance (PD ID 4680119); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Air Tempo ATCB12K454B-O* reach 25.0 SEER2?

Peak 25.0 SEER2 represents the top tested AHRI pairing for Air Tempo ATCB12K454B-O* (PD ID 4680119); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Air Tempo ATCB12K454B-O*?

Air Tempo ATCB12K454B-O* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ADB DBED-T12IH3A1-E*.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.