TGM ARHHBT12ASA — Mini-Split Heat Pump Specifications
TGM ARHHBT12ASA (Mini-Split Heat Pump, PD ID 4663286) holds 1 ENERGY STAR certified SKU rated at 24.0 SEER2 — #1,599 of 2,096 (411 tied, beats 4.2% of peers), -1.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). TGM ARHHBT12ASA — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.0 SEER2 and Heating Rating set at 10.0 HSPF2.
- Max SEER2
- 24.0 SEER2
- Heating Rating
- 10.0 HSPF2
- Heating COP
- 2.1 COP
- Cohort Rank
- #1,599/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 4663286
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | This series |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does TGM ARHHBT12ASA rank across federal compliance and ENERGY STAR cohorts?
TGM ARHHBT12ASA ranks #1,599 of 2,096 (tied with 410 others at 24.0 SEER2, more efficient than 4.2% of certified series) for Max SEER2 (-1.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (75.6% capacity retention at 5F) (1.0 nominal Tons at 12,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #1,599 of 2,096 (411 tied, beats 4.2% of peers) | -1.10 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.0 HSPF2 | -0.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 12.0 EER2 | -2.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 75.6% of 47F rating | 5F COP 2.1 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.0 SEER2 / 10.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does TGM ARHHBT12ASA require?
Annual cost outputs combine TGM ARHHBT12ASA's 24.0 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 500 kWh/yr | $82/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 3,000 kWh/yr | $490/yr at US median |
| Combined Annual Electricity Cost | $572/yr | State range: $445 (NV) to $1,651 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,339 kWh/yr | $219/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to TGM ARHHBT12ASA?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for TGM ARHHBT12ASA (PD ID 4663286).
| ARHHBT12ASA | AWHHBT12SA | 12,000 BTU/h | 24.0 SEER2 / 10.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on TGM ARHHBT12ASA, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across TGM ARHHBT12ASA: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for TGM ARHHBT12ASA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- TGM ARHHBT12ASA uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal TGM ARHHBT12ASA fit | Single-family replacement needing documented ENERGY STAR PD ID 4663286 with matching indoor air handler. |
| Skip TGM ARHHBT12ASA if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare TGM ARHHBT12ASA against Kinghome KW12HQ25SDO and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does TGM ARHHBT12ASA compare with peer Mini-Split Heat Pump units?
TGM ARHHBT12ASA holds #1,599 of 2,096 (411 tied, beats 4.2% of peers) out of 2,096 verified mini-split heat pump models (-1.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.0 SEER2. Closest same-cohort alternatives include Kinghome KW12HQ25SDO.
Where is TGM ARHHBT12ASA compliant for 2026 US installation?
TGM ARHHBT12ASA: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does TGM ARHHBT12ASA model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, TGM ARHHBT12ASA runs 500 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does TGM ARHHBT12ASA cover?
TGM ARHHBT12ASA covers 12,000-12,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does TGM ARHHBT12ASA handle extreme weather or cold snaps?
Yes, TGM ARHHBT12ASA carries ENERGY STAR Cold Climate certification (75.6% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern TGM ARHHBT12ASA?
TGM ARHHBT12ASA specifies R-32 compliance (PD ID 4663286); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in TGM ARHHBT12ASA reach 24.0 SEER2?
Peak 24.0 SEER2 represents the top tested AHRI pairing for TGM ARHHBT12ASA (PD ID 4663286); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to TGM ARHHBT12ASA?
TGM ARHHBT12ASA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Kinghome KW12HQ25SDO.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.