Skip to main content
Mini-Split Heat Pump · THERMOFLUX · 1 ENERGY STAR Combinations

THERMOFLUX TMFX48HEI2NAS0U25 — Mini-Split Heat Pump Specifications

THERMOFLUX TMFX48HEI2NAS0U25 (Mini-Split Heat Pump, PD ID 4577106) holds 1 ENERGY STAR certified SKU rated at 24.0 SEER2 — #1,599 of 2,096 (411 tied, beats 4.2% of peers), -1.10 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). THERMOFLUX TMFX48HEI2NAS0U25 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 24.0 SEER2 and Heating Rating set at 10.0 HSPF2.

Max SEER2
24.0 SEER2
Heating Rating
10.0 HSPF2
Heating COP
2.0 COP
Cohort Rank
#1,599/2,096
Verified Combos
1 SKU
Sample PD ID
4577106
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
THERMOFLUX TMFX48HEI2NAS0U25 Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. THERMOFLUX TMFX48HEI2NAS0U25 sits at 24.0 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 24.0 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717This series
25.0 - 26.2 SEER2785Peer range
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
THERMOFLUX TMFX48HEI2NAS0U25 residential equipment inspection. ThermalSpec Editorial Photography

How does THERMOFLUX TMFX48HEI2NAS0U25 rank across federal compliance and ENERGY STAR cohorts?

THERMOFLUX TMFX48HEI2NAS0U25 ranks #1,599 of 2,096 (tied with 410 others at 24.0 SEER2, more efficient than 4.2% of certified series) for Max SEER2 (-1.10 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Rated for cold-climate output (87.5% capacity retention at 5F) (4.0 nominal Tons at 48,000 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

THERMOFLUX TMFX48HEI2NAS0U25 Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #1,599 of 2,096 (411 tied, beats 4.2% of peers) -1.10 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 10.0 HSPF2 -0.50 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 12.3 EER2 -1.70 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 87.5% of 47F rating 5F COP 2.0
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 24.0 SEER2 / 10.0 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 12.3 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does THERMOFLUX TMFX48HEI2NAS0U25 require?

Modeled utility figures for THERMOFLUX TMFX48HEI2NAS0U25 (THERMOFLUX) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.

Cool_kWh = (48,000 BTU/h * 1,000 hrs / 24.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 10.0 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy2,000 kWh/yr$327/yr at US median
Estimated Annual Heating Energy (30 MMBtu)3,000 kWh/yr$490/yr at US median
Combined Annual Electricity Cost$816/yrState range: $636 (NV) to $2,359 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor2,357 kWh/yr$385/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to THERMOFLUX TMFX48HEI2NAS0U25?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for THERMOFLUX TMFX48HEI2NAS0U25 (PD ID 4577106).

TMFX48HEI2NAS0U25 Matched AHRI Coil 48,000 BTU/h 24.0 SEER2 / 10.0 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on THERMOFLUX TMFX48HEI2NAS0U25, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across THERMOFLUX TMFX48HEI2NAS0U25: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for THERMOFLUX TMFX48HEI2NAS0U25 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • THERMOFLUX TMFX48HEI2NAS0U25 uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal THERMOFLUX TMFX48HEI2NAS0U25 fitSingle-family replacement needing documented ENERGY STAR PD ID 4577106 with matching indoor air handler.
Skip THERMOFLUX TMFX48HEI2NAS0U25 ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare THERMOFLUX TMFX48HEI2NAS0U25 against Clima Smart MU-CSU48HEI2NAM0T24-6PO and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

Clima Smart MU-CSU48HEI2NAM0T24-6PO

24.0 SEER2 · 10.0 HSPF2 · 48,000 BTU/h

DELLA 048-TPH-MODU-1D6

24.0 SEER2 · 10.0 HSPF2 · 48,000 BTU/h

ForestAir FA-MY48-D5TL-O-454

24.0 SEER2 · 10.0 HSPF2 · 48,000 BTU/h

ForestAir FA-MY55-D5TL-O-454

24.0 SEER2 · 10.0 HSPF2 · 48,000 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does THERMOFLUX TMFX48HEI2NAS0U25 compare with peer Mini-Split Heat Pump units?

THERMOFLUX TMFX48HEI2NAS0U25 holds #1,599 of 2,096 (411 tied, beats 4.2% of peers) out of 2,096 verified mini-split heat pump models (-1.10 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 24.0 SEER2. Closest same-cohort alternatives include Clima Smart MU-CSU48HEI2NAM0T24-6PO.

DOE Regions

Where is THERMOFLUX TMFX48HEI2NAS0U25 compliant for 2026 US installation?

THERMOFLUX TMFX48HEI2NAS0U25: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does THERMOFLUX TMFX48HEI2NAS0U25 model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, THERMOFLUX TMFX48HEI2NAS0U25 runs 2,000 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does THERMOFLUX TMFX48HEI2NAS0U25 cover?

THERMOFLUX TMFX48HEI2NAS0U25 covers 48,000-48,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does THERMOFLUX TMFX48HEI2NAS0U25 handle extreme weather or cold snaps?

Yes, THERMOFLUX TMFX48HEI2NAS0U25 carries ENERGY STAR Cold Climate certification (87.5% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern THERMOFLUX TMFX48HEI2NAS0U25?

THERMOFLUX TMFX48HEI2NAS0U25 specifies R-454B compliance (PD ID 4577106); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in THERMOFLUX TMFX48HEI2NAS0U25 reach 24.0 SEER2?

Peak 24.0 SEER2 represents the top tested AHRI pairing for THERMOFLUX TMFX48HEI2NAS0U25 (PD ID 4577106); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to THERMOFLUX TMFX48HEI2NAS0U25?

THERMOFLUX TMFX48HEI2NAS0U25 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Clima Smart MU-CSU48HEI2NAM0T24-6PO.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros