GE Appliances ASH109URDSE* — Mini-Split Heat Pump Specifications
GE Appliances ASH109URDSE* (Mini-Split Heat Pump, PD ID 2469987) holds 1 ENERGY STAR certified SKU rated at 30.0 SEER2 — #87 of 2,096 (Top 5.3%, 26 tied), +4.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). GE Appliances ASH109URDSE* — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 30.0 SEER2 and Heating Rating set at 14.0 HSPF2.
- Max SEER2
- 30.0 SEER2
- Heating Rating
- 14.0 HSPF2
- Heating COP
- 1.8 COP
- Cohort Rank
- #87/2,096
- Verified Combos
- 1 SKU
- Sample PD ID
- 2469987
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | This series |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does GE Appliances ASH109URDSE* rank across federal compliance and ENERGY STAR cohorts?
GE Appliances ASH109URDSE* ranks #87 of 2,096 (tied with 25 others at 30.0 SEER2, top 5.3%, more efficient than 94.7% of certified series) for Max SEER2 (+4.90 SEER2 vs 25.1 SEER2 category median) across 1 certified SKU combination. Built with Continuously variable modulation (0.8 nominal Tons at 9,000 BTU/h) charged with R-410A. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #87 of 2,096 (Top 5.3%, 26 tied) | +4.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 14.0 HSPF2 | +3.50 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 16.0 EER2 | +2.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 59.0% of 47F rating | 5F COP 1.8 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 30.0 SEER2 / 14.0 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 16.0 EER2 |
| ENERGY STAR Cold Climate Spec | STANDARD CLIMATE | Designed for standard/mixed heating zones |
| 2026 Cleaner Refrigerant Rule | OLDER R-410A | Listed refrigerant: R-410A; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does GE Appliances ASH109URDSE* require?
Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, GE Appliances ASH109URDSE* estimates reflect 1 certified SKU combination tested under PD ID 2469987.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 300 kWh/yr | $49/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,143 kWh/yr | $350/yr at US median |
| Combined Annual Electricity Cost | $399/yr | State range: $311 (NV) to $1,153 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 2,186 kWh/yr | $357/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to GE Appliances ASH109URDSE*?
Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for GE Appliances ASH109URDSE* (PD ID 2469987).
| ASH109URDSE* | ASYW09URDWD* | 9,000 BTU/h | 30.0 SEER2 / 14.0 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on GE Appliances ASH109URDSE*, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across GE Appliances ASH109URDSE*: headline Max SEER2 reflects peak tested matches among 1 SKU, not lower-rated sizes.
- Catalog specs for GE Appliances ASH109URDSE* exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- GE Appliances ASH109URDSE* lacks ENERGY STAR Cold Climate 5F designation, so electric heat strips or dual-fuel backup matter in Zones 5-8.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal GE Appliances ASH109URDSE* fit | Single-family replacement needing documented ENERGY STAR PD ID 2469987 with matching indoor air handler. |
| Skip GE Appliances ASH109URDSE* if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare GE Appliances ASH109URDSE* against Fujitsu AOUH09KMAS1 and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does GE Appliances ASH109URDSE* compare with peer Mini-Split Heat Pump units?
GE Appliances ASH109URDSE* holds #87 of 2,096 (Top 5.3%, 26 tied) out of 2,096 verified mini-split heat pump models (+4.90 SEER2 vs 25.1 SEER2 category median), spanning 1 certified SKU up to 30.0 SEER2. Closest same-cohort alternatives include Fujitsu AOUH09KMAS1.
Where is GE Appliances ASH109URDSE* compliant for 2026 US installation?
GE Appliances ASH109URDSE*: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does GE Appliances ASH109URDSE* model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, GE Appliances ASH109URDSE* runs 300 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does GE Appliances ASH109URDSE* cover?
GE Appliances ASH109URDSE* covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does GE Appliances ASH109URDSE* handle extreme weather or cold snaps?
GE Appliances ASH109URDSE* is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.
What refrigerant class and 2026 tax credit rules govern GE Appliances ASH109URDSE*?
GE Appliances ASH109URDSE* specifies R-410A compliance (PD ID 2469987); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 1 certified SKU in GE Appliances ASH109URDSE* reach 30.0 SEER2?
Peak 30.0 SEER2 represents the top tested AHRI pairing for GE Appliances ASH109URDSE* (PD ID 2469987); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to GE Appliances ASH109URDSE*?
GE Appliances ASH109URDSE* requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Fujitsu AOUH09KMAS1.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 8 pages.