Fujitsu AOUH09KMAS1 — Mini-Split Heat Pump Specifications
Fujitsu AOUH09KMAS1 (Mini-Split Heat Pump, PD ID 4587096) holds 2 ENERGY STAR certified SKUs rated at 30.0 SEER2 — #87 of 2,096 (Top 5.3%, 26 tied), +4.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). Fujitsu AOUH09KMAS1 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 30.0 SEER2 and Heating Rating set at 12.6 HSPF2.
- Max SEER2
- 30.0 SEER2
- Heating Rating
- 12.6 HSPF2
- Heating COP
- 2.32 COP
- Cohort Rank
- #87/2,096
- Verified Combos
- 2 SKUs
- Sample PD ID
- 4587096
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | Peer range |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | This series |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does Fujitsu AOUH09KMAS1 rank across federal compliance and ENERGY STAR cohorts?
Fujitsu AOUH09KMAS1 ranks #87 of 2,096 (tied with 25 others at 30.0 SEER2, top 5.3%, more efficient than 94.7% of certified series) for Max SEER2 (+4.90 SEER2 vs 25.1 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (85.8% capacity retention at 5F) (0.8 nominal Tons at 9,000 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #87 of 2,096 (Top 5.3%, 26 tied) | +4.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 12.6 HSPF2 | +2.10 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 16.4 EER2 | +2.40 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 85.8% of 47F rating | 5F COP 2.32 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 30.0 SEER2 / 12.6 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 16.4 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does Fujitsu AOUH09KMAS1 require?
Annual cost outputs combine Fujitsu AOUH09KMAS1's 30.0 SEER2 rating and EIA national tariffs across single-family runtime hours.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 300 kWh/yr | $49/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,381 kWh/yr | $389/yr at US median |
| Combined Annual Electricity Cost | $438/yr | State range: $341 (NV) to $1,265 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,948 kWh/yr | $318/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to Fujitsu AOUH09KMAS1?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for Fujitsu AOUH09KMAS1 (PD ID 4587096).
| AOUH09KMAS1 | ASUH09KMBS | 9,000 BTU/h | 30.0 SEER2 / 12.6 HSPF2 |
| AOUH09KMAS1 | ASUH09KMAS | 9,000 BTU/h | 30.0 SEER2 / 12.6 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Fujitsu AOUH09KMAS1, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across Fujitsu AOUH09KMAS1: headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for Fujitsu AOUH09KMAS1 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- Fujitsu AOUH09KMAS1 uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal Fujitsu AOUH09KMAS1 fit | Single-family replacement needing documented ENERGY STAR PD ID 4587096 with matching indoor air handler. |
| Skip Fujitsu AOUH09KMAS1 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare Fujitsu AOUH09KMAS1 against GE Appliances ASH109URDE** and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does Fujitsu AOUH09KMAS1 compare with peer Mini-Split Heat Pump units?
Fujitsu AOUH09KMAS1 holds #87 of 2,096 (Top 5.3%, 26 tied) out of 2,096 verified mini-split heat pump models (+4.90 SEER2 vs 25.1 SEER2 category median), spanning 2 certified SKUs up to 30.0 SEER2. Closest same-cohort alternatives include GE Appliances ASH109URDE**.
Where is Fujitsu AOUH09KMAS1 compliant for 2026 US installation?
Fujitsu AOUH09KMAS1: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does Fujitsu AOUH09KMAS1 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, Fujitsu AOUH09KMAS1 runs 300 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does Fujitsu AOUH09KMAS1 cover?
Fujitsu AOUH09KMAS1 covers 9,000-9,000 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does Fujitsu AOUH09KMAS1 handle extreme weather or cold snaps?
Yes, Fujitsu AOUH09KMAS1 carries ENERGY STAR Cold Climate certification (85.8% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern Fujitsu AOUH09KMAS1?
Fujitsu AOUH09KMAS1 specifies R-32 compliance (PD ID 4587096); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in Fujitsu AOUH09KMAS1 reach 30.0 SEER2?
Peak 30.0 SEER2 represents the top tested AHRI pairing for Fujitsu AOUH09KMAS1 (PD ID 4587096); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to Fujitsu AOUH09KMAS1?
Fujitsu AOUH09KMAS1 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include GE Appliances ASH109URDE**.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)