Skip to main content
Mini-Split Heat Pump · BOREAL · 3 ENERGY STAR Combinations

BOREAL KUL09HPJ132OA — Mini-Split Heat Pump Specifications

BOREAL KUL09HPJ132OA (Mini-Split Heat Pump, PD ID 3624640) holds 3 ENERGY STAR certified SKUs rated at 26.0 SEER2 — #595 of 2,096 (Top 33.4%, 106 tied), +0.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). BOREAL KUL09HPJ132OA — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.0 SEER2 and Heating Rating set at 10.4 HSPF2.

Max SEER2
26.0 SEER2
Heating Rating
10.4 HSPF2
Heating COP
1.95 COP
Cohort Rank
#595/2,096
Verified Combos
3 SKUs
Sample PD ID
3624640
Mini-Split Heat Pump Efficiency Spread across 2096 certified series (23.7 to 35.1 SEER2)
BOREAL KUL09HPJ132OA Mini-Split Heat Pump Efficiency Spread Distribution Distribution of 2096 certified series from 23.7 to 35.1 SEER2. BOREAL KUL09HPJ132OA sits at 26.0 SEER2; typical midpoint is 25.1 SEER2. 717 23.7 785 25.0 272 26.2 150 27.5 86 28.8 1 30.0 28 31.3 38 32.6 19 33.8 Median 25.1 SEER2 This model: 26.0 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
23.7 - 25.0 SEER2717Peer range
25.0 - 26.2 SEER2785This series
26.2 - 27.5 SEER2272Peer range
27.5 - 28.8 SEER2150Peer range
28.8 - 30.0 SEER286Peer range
30.0 - 31.3 SEER21Peer range
31.3 - 32.6 SEER228Peer range
32.6 - 33.8 SEER238Peer range
33.8 - 35.1 SEER219Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
BOREAL KUL09HPJ132OA residential equipment inspection. ThermalSpec Editorial Photography

How does BOREAL KUL09HPJ132OA rank across federal compliance and ENERGY STAR cohorts?

BOREAL KUL09HPJ132OA ranks #595 of 2,096 (tied with 105 others at 26.0 SEER2, top 33.4%, more efficient than 66.6% of certified series) for Max SEER2 (+0.90 SEER2 vs 25.1 SEER2 category median) across 3 certified SKU combinations. Rated for cold-climate output (95.2% capacity retention at 5F) (0.8 nominal Tons at 9,100 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

BOREAL KUL09HPJ132OA Cohort Metrics vs. Mini-Split Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #595 of 2,096 (Top 33.4%, 106 tied) +0.90 SEER2 vs 25.1 SEER2 category median
Heating HSPF2 vs Cohort 10.4 HSPF2 -0.10 HSPF2 vs 10.5 HSPF2 median
Peak 95F EER2 vs Cohort 15.0 EER2 +1.00 EER2 vs 14.0 EER2 median
5F Cold-Weather Capacity Retention 95.2% of 47F rating 5F COP 1.95
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.0 SEER2 / 10.4 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.0 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (1947/2096 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does BOREAL KUL09HPJ132OA require?

Annual cost outputs combine BOREAL KUL09HPJ132OA's 26.0 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (9,100 BTU/h * 1,000 hrs / 26.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 10.4 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy350 kWh/yr$57/yr at US median
Estimated Annual Heating Energy (30 MMBtu)2,885 kWh/yr$471/yr at US median
Combined Annual Electricity Cost$528/yrState range: $411 (NV) to $1,526 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,401 kWh/yr$229/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to BOREAL KUL09HPJ132OA?

Showing 3 certified indoor-outdoor coil combinations from 3 total AHRI matched records filed for BOREAL KUL09HPJ132OA (PD ID 3624640).

KUL09HPJ132OA KUL09HPJ132IA 9,100 BTU/h 26.0 SEER2 / 10.4 HSPF2
KUL09HPJ132OA FLR09HPJ132IA 9,100 BTU/h 25.0 SEER2 / 9.6 HSPF2
KUL09HPJ132OA CAS09HPJ132IA 9,100 BTU/h 24.0 SEER2 / 9.2 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on BOREAL KUL09HPJ132OA, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across BOREAL KUL09HPJ132OA: headline Max SEER2 reflects peak tested matches among 3 SKUs, not lower-rated sizes.
  • Catalog specs for BOREAL KUL09HPJ132OA exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • BOREAL KUL09HPJ132OA uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal BOREAL KUL09HPJ132OA fitSingle-family replacement needing documented ENERGY STAR PD ID 3624640 with matching indoor air handler.
Skip BOREAL KUL09HPJ132OA ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable mini-split heat pump models deliver similar efficiency?

Compare BOREAL KUL09HPJ132OA against AireForce DXH09PSK3IH and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.

AireForce DXH09PSK3IH

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

Airtemp DXH09PSK3IH

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

BLUERIDGE BXS4Z09UC0

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

ECO AC EHH-O09KBB

26.0 SEER2 · 10.4 HSPF2 · 9,100 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does BOREAL KUL09HPJ132OA compare with peer Mini-Split Heat Pump units?

BOREAL KUL09HPJ132OA holds #595 of 2,096 (Top 33.4%, 106 tied) out of 2,096 verified mini-split heat pump models (+0.90 SEER2 vs 25.1 SEER2 category median), spanning 3 certified SKUs up to 26.0 SEER2. Closest same-cohort alternatives include AireForce DXH09PSK3IH.

DOE Regions

Where is BOREAL KUL09HPJ132OA compliant for 2026 US installation?

BOREAL KUL09HPJ132OA: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does BOREAL KUL09HPJ132OA model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, BOREAL KUL09HPJ132OA runs 350 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does BOREAL KUL09HPJ132OA cover?

BOREAL KUL09HPJ132OA covers 9,100-9,100 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does BOREAL KUL09HPJ132OA handle extreme weather or cold snaps?

Yes, BOREAL KUL09HPJ132OA carries ENERGY STAR Cold Climate certification (95.2% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern BOREAL KUL09HPJ132OA?

BOREAL KUL09HPJ132OA specifies R-32 compliance (PD ID 3624640); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 3 certified SKUs in BOREAL KUL09HPJ132OA reach 26.0 SEER2?

Peak 26.0 SEER2 represents the top tested AHRI pairing for BOREAL KUL09HPJ132OA (PD ID 3624640); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to BOREAL KUL09HPJ132OA?

BOREAL KUL09HPJ132OA requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AireForce DXH09PSK3IH.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros