BLUERIDGE BXS4Z09UC0 — Mini-Split Heat Pump Specifications
BLUERIDGE BXS4Z09UC0 (Mini-Split Heat Pump, PD ID 4428982) holds 2 ENERGY STAR certified SKUs rated at 26.0 SEER2 — #595 of 2,096 (Top 33.4%, 106 tied), +0.90 SEER2. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). BLUERIDGE BXS4Z09UC0 — Mini-Split Heat Pump Specifications benchmarks residential systems using Max SEER2 set at 26.0 SEER2 and Heating Rating set at 10.4 HSPF2.
- Max SEER2
- 26.0 SEER2
- Heating Rating
- 10.4 HSPF2
- Heating COP
- 1.94 COP
- Cohort Rank
- #595/2,096
- Verified Combos
- 2 SKUs
- Sample PD ID
- 4428982
Inspect chart data table (9 rows)
| Efficiency Band | Series Count | Position |
|---|---|---|
| 23.7 - 25.0 SEER2 | 717 | Peer range |
| 25.0 - 26.2 SEER2 | 785 | This series |
| 26.2 - 27.5 SEER2 | 272 | Peer range |
| 27.5 - 28.8 SEER2 | 150 | Peer range |
| 28.8 - 30.0 SEER2 | 86 | Peer range |
| 30.0 - 31.3 SEER2 | 1 | Peer range |
| 31.3 - 32.6 SEER2 | 28 | Peer range |
| 32.6 - 33.8 SEER2 | 38 | Peer range |
| 33.8 - 35.1 SEER2 | 19 | Peer range |
How does BLUERIDGE BXS4Z09UC0 rank across federal compliance and ENERGY STAR cohorts?
BLUERIDGE BXS4Z09UC0 ranks #595 of 2,096 (tied with 105 others at 26.0 SEER2, top 33.4%, more efficient than 66.6% of certified series) for Max SEER2 (+0.90 SEER2 vs 25.1 SEER2 category median) across 2 certified SKU combinations. Rated for cold-climate output (90.5% capacity retention at 5F) (0.8 nominal Tons at 9,100 BTU/h) charged with R-32. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.
| Cohort Benchmark | Series Metric | Dataset Context |
|---|---|---|
| Category Rank (Max SEER2) | #595 of 2,096 (Top 33.4%, 106 tied) | +0.90 SEER2 vs 25.1 SEER2 category median |
| Heating HSPF2 vs Cohort | 10.4 HSPF2 | -0.10 HSPF2 vs 10.5 HSPF2 median |
| Peak 95F EER2 vs Cohort | 15.0 EER2 | +1.00 EER2 vs 14.0 EER2 median |
| 5F Cold-Weather Capacity Retention | 90.5% of 47F rating | 5F COP 1.94 |
| Compliance Rule | Status | Engineering Criterion |
|---|---|---|
| Federal North & SE Heat Pump Minimum | PASS | Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 26.0 SEER2 / 10.4 HSPF2 |
| Southwest Peak-Heat Criterion (AZ/CA/NM/NV) | PASS | Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 15.0 EER2 |
| ENERGY STAR Cold Climate Spec | CERTIFIED | Cold Climate verified (1947/2096 series in category) |
| 2026 Cleaner Refrigerant Rule | R-454B / R-32 READY | Listed refrigerant: R-32; newer R-454B/R-32 splits include indoor leak sensors |
How much annual energy and operating cost does BLUERIDGE BXS4Z09UC0 require?
Modeled utility figures for BLUERIDGE BXS4Z09UC0 (BLUERIDGE) apply US median residential rates (16.33 c/kWh electric, $1.45/therm gas) to published Max SEER2 ratings.
| Operating Basis | Estimated Value | Source Basis |
|---|---|---|
| Estimated Annual Cooling Energy | 350 kWh/yr | $57/yr at US median |
| Estimated Annual Heating Energy (30 MMBtu) | 2,885 kWh/yr | $471/yr at US median |
| Combined Annual Electricity Cost | $528/yr | State range: $411 (NV) to $1,526 (HI) |
| Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor | 1,401 kWh/yr | $229/yr saved |
When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.
Which AHRI certified SKU combinations belong to BLUERIDGE BXS4Z09UC0?
Showing 2 certified indoor-outdoor coil combinations from 2 total AHRI matched records filed for BLUERIDGE BXS4Z09UC0 (PD ID 4428982).
| BXS4Z09UC0 | BXS4Z09WM0 | 9,100 BTU/h | 26.0 SEER2 / 10.4 HSPF2 |
| BXS4Z09UC0 | BXAFZ09CC8 | 9,100 BTU/h | 24.0 SEER2 / 9.2 HSPF2 |
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on BLUERIDGE BXS4Z09UC0, review 3 important real-world limits and verify local licensing and permit rules directly.
- Coil pairing spread across BLUERIDGE BXS4Z09UC0: headline Max SEER2 reflects peak tested matches among 2 SKUs, not lower-rated sizes.
- Catalog specs for BLUERIDGE BXS4Z09UC0 exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
- BLUERIDGE BXS4Z09UC0 uses A2L R-32, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Ideal BLUERIDGE BXS4Z09UC0 fit | Single-family replacement needing documented ENERGY STAR PD ID 4428982 with matching indoor air handler. |
| Skip BLUERIDGE BXS4Z09UC0 if | Manual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed. |
Which comparable mini-split heat pump models deliver similar efficiency?
Compare BLUERIDGE BXS4Z09UC0 against AireForce DXH09PSK3IH and closely matched mini-split heat pump units sharing similar Max SEER2 output and BTU tonnage.
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
How does BLUERIDGE BXS4Z09UC0 compare with peer Mini-Split Heat Pump units?
BLUERIDGE BXS4Z09UC0 holds #595 of 2,096 (Top 33.4%, 106 tied) out of 2,096 verified mini-split heat pump models (+0.90 SEER2 vs 25.1 SEER2 category median), spanning 2 certified SKUs up to 26.0 SEER2. Closest same-cohort alternatives include AireForce DXH09PSK3IH.
Where is BLUERIDGE BXS4Z09UC0 compliant for 2026 US installation?
BLUERIDGE BXS4Z09UC0: Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.
What annual operating cost does BLUERIDGE BXS4Z09UC0 model at US tariffs?
At 16.33 c/kWh electricity and $1.45/therm gas, BLUERIDGE BXS4Z09UC0 runs 350 kWh/yr across standard cooling/heating hours.
What capacity band and airflow does BLUERIDGE BXS4Z09UC0 cover?
BLUERIDGE BXS4Z09UC0 covers 9,100-9,100 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.
How does BLUERIDGE BXS4Z09UC0 handle extreme weather or cold snaps?
Yes, BLUERIDGE BXS4Z09UC0 carries ENERGY STAR Cold Climate certification (90.5% capacity retention at 5 F).
What refrigerant class and 2026 tax credit rules govern BLUERIDGE BXS4Z09UC0?
BLUERIDGE BXS4Z09UC0 specifies R-32 compliance (PD ID 4428982); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.
Do all 2 certified SKUs in BLUERIDGE BXS4Z09UC0 reach 26.0 SEER2?
Peak 26.0 SEER2 represents the top tested AHRI pairing for BLUERIDGE BXS4Z09UC0 (PD ID 4428982); exact tonnage and indoor coil selections vary final EER2/HSPF2.
What licensing and safety checks apply to BLUERIDGE BXS4Z09UC0?
BLUERIDGE BXS4Z09UC0 requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include AireForce DXH09PSK3IH.
Sources
Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Mini-Split Heat Pumps Dataset (akti-mt5s) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
- Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)
Related Pages
Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.