ThermalSpec indexes 50 Heil air-source heat pumps models spanning 23,200-46,500 BTU/h, anchored by H5H3V36*K*AAA* (EVD5X61M 3.0T) (23.0 SEER2) and H5H3V48*K*AAA* (FCMA5B48 3.8T) (22.0 SEER2). Heil Air-Source Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 50 and Rating Span set at 22.0 SEER2 - 23.0 SEER2.

Certified Models
50
Rating Span
22.0 SEER2 - 23.0 SEER2
Capacity Range
23,200-46,500 BTU/h
AHRI Combinations
330
Cold Climate Units
50
Category Median
22.0 SEER2
Residential air handler cabinet with galvanized ductwork and brazed copper piping
Heil Air-Source Heat Pumps — ENERGY STAR Certified Models editorial reference. ThermalSpec Editorial Photography

How does Heil's air-source heat pumps portfolio cover capacity, refrigerants, and safety?

Heil covers 23,200-46,500 BTU/h in air-source heat pumps across 50 canonical models and 330 AHRI combinations, with 50 Cold Climate certified models and R-454B. Ratings span 22.0 SEER2 up to 23.0 SEER2 (category median 22.0 SEER2, certified through 2026-07-16). CPSC records show 0 residential HVAC recall notices matching Heil; check exact AHRI matched pairings on individual model sheets.

Showing 50 entries

Which verified records belong in Heil Air-Source Heat Pumps — ENERGY STAR Certified Models?

Compare all 50 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.

All 50 ENERGY STAR Heil Air-Source Heat Pumps Models
Heil H5H3V36*K*AAA* (EVD5X61M 3.0T) 22.5 SEER2 9.0 HSPF2 35,800-36,000 23
Heil B5H3V36*K*AAA* (EVD5X61M 3.0T) 22.5 SEER2 9.0 HSPF2 35,800-36,000 21
Heil H5H3V36*K*AAA* (EVD5X60M 3.0T) 22.0 SEER2 9.0 HSPF2 35,600-35,800 20
Heil H5H3V36*K*AAA* (EVM5X60M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 20
Heil B5H3V36*K*AAA* (EVD5X60M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600-35,800 18
Heil B5H3V36*K*AAA* (EVM5X60M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 18
Heil B5H3V24*K*AAA* (EVD5X38M 2.0T) 23.0 SEER2 9.5 HSPF2 23,600-23,800 12
Heil B5H3V24*K*AAA* (EVM5X32M 2.0T) 23.0 SEER2 9.5 HSPF2 23,600-23,800 11
Heil B5H3V24*K*AAA* (EVM5X44M 2.0T) 23.0 SEER2 9.5 HSPF2 23,600-23,800 11
Heil H5H3V36*K*AAA* (EVM5X44M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 11
Heil H5H3V36*K*AAA* (EVM5X49M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 10
Heil H5H3V36*K*AAA* (EVM5X61M 3.0T) 22.5 SEER2 8.5 HSPF2 35,800-36,000 9
Heil B5H3V36*K*AAA* (EVD5X42M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 9
Heil B5H3V36*K*AAA* (EVM5X44M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 9
Heil B5H3V36*K*AAA* (EVM5X49M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 9
Heil H5H3V36*K*AAA* (EVD5X42M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 9
Heil B5H3V36*K*AAA* (EVM5X61M 3.0T) 22.5 SEER2 8.5 HSPF2 35,800-36,000 8
Heil B5H3V24*K*AAA* (EVD5X37M 1.9T) 22.5 SEER2 9.5 HSPF2 23,200-23,400 7
Heil B5H3V24*K*AAA* (EVM5X43M 1.9T) 22.5 SEER2 9.5 HSPF2 23,200-23,400 7
Heil B5H3V24*K*AAA* (EVD5X42M 1.9T) 22.0 SEER2 9.5 HSPF2 23,200-23,400 7
Heil B5H3V24*K*AAA* (EVD5X31M 2.0T) 22.5 SEER2 9.5 HSPF2 23,600 BTU/h 6
Heil B5H3V24*K*AAA* (EVM5X31M 1.9T) 22.0 SEER2 9.5 HSPF2 23,400 BTU/h 6
Heil B5H3V36*K*AAA* (EVD5X49M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 6
Heil H5H3V36*K*AAA* (EVD5X49M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 6
Heil B5H3V24*K*AAA* (EVM5X31M 2.0T) 22.5 SEER2 9.5 HSPF2 23,600 BTU/h 5
Heil B5H3V24*K*AAA* (EVD5X31M 1.9T) 22.0 SEER2 9.5 HSPF2 23,400 BTU/h 5
Heil B5H3V24*K*AAA* (EVD5X36M 1.9T) 22.0 SEER2 9.5 HSPF2 23,200 BTU/h 5
Heil B5H3V36*K*AAA* (EVD5X49M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 4
Heil H5H3V36*K*AAA* (EVD5X49M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 4
Heil B5H3V24*K*AAA* (EVM5X25M 1.9T) 22.0 SEER2 9.5 HSPF2 23,000-23,200 3
Heil B5H3V24*K*AAA* (EVM5X30M 1.9T) 22.0 SEER2 9.5 HSPF2 23,000-23,200 3
Heil B5H3V24*K*AAA* (EVM5X36M 1.9T) 22.0 SEER2 9.5 HSPF2 23,000-23,200 3
Heil B5H3V24*K*AAA* (EVM5X42M 1.9T) 22.0 SEER2 9.5 HSPF2 23,200 BTU/h 3
Heil B5H3V24*K*AAA* (EVD5X25M 1.9T) 22.0 SEER2 9.5 HSPF2 23,200 BTU/h 2
Heil B5H3V24*K*AAA* (EVD5X30M 1.9T) 22.0 SEER2 9.5 HSPF2 23,200 BTU/h 2
Heil B5H3V36*K*AAA* (EVD5X38M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 2
Heil H5H3V36*K*AAA* (EVD5X38M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 2
Heil H5H3V36*K*AAA* (EVD5X38M 3.0T) 22.0 SEER2 8.5 HSPF2 35,600 BTU/h 2
Heil B5H3V48*K*AAA* (FCMA5B60 3.9T) 23.0 SEER2 9.5 HSPF2 46,500 BTU/h 1
Heil H5H3V48*K*AAA* (FCMA5B60 3.9T) 23.0 SEER2 9.5 HSPF2 46,500 BTU/h 1
Heil B5H3V36*K*AAA* (EVD5X42M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 1
Heil B5H3V36*K*AAA* (EVD5X60M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 1
Heil B5H3V36*K*AAA* (EVM5X60M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 1
Heil B5H3V36*K*AAA* (FCMA5B60 2.9T) 22.0 SEER2 9.5 HSPF2 35,000 BTU/h 1
Heil B5H3V48*K*AAA* (FCMA5B48 3.8T) 22.0 SEER2 9.5 HSPF2 45,500 BTU/h 1
Heil H5H3V36*K*AAA* (EVD5X42M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 1
Heil H5H3V36*K*AAA* (EVD5X60M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 1
Heil H5H3V36*K*AAA* (EVM5X60M 3.0T) 22.0 SEER2 8.5 HSPF2 35,400 BTU/h 1
Heil H5H3V36*K*AAA* (FCMA5B60 2.9T) 22.0 SEER2 9.5 HSPF2 35,000 BTU/h 1
Heil H5H3V48*K*AAA* (FCMA5B48 3.8T) 22.0 SEER2 9.5 HSPF2 45,500 BTU/h 1

Which top Heil air-source heat pumps anchor this lineup?

Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.

Heil22.5 SEER2

Heil H5H3V36*K*AAA* (EVD5X61M 3.0T)

9.0 HSPF2 | 35,800-36,000 | 23 SKUs

Heil22.5 SEER2

Heil B5H3V36*K*AAA* (EVD5X61M 3.0T)

9.0 HSPF2 | 35,800-36,000 | 21 SKUs

Heil22.0 SEER2

Heil H5H3V36*K*AAA* (EVD5X60M 3.0T)

9.0 HSPF2 | 35,600-35,800 | 20 SKUs

Heil22.0 SEER2

Heil H5H3V36*K*AAA* (EVM5X60M 3.0T)

8.5 HSPF2 | 35,600 BTU/h | 20 SKUs

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Heil Air-Source Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.

  • Cohort spread across Heil: 22.0 SEER2 entry units differ substantially from flagship H5H3V36*K*AAA* (EVD5X61M 3.0T) (23.0 SEER2).
  • Verify indoor coil AHRI pairing on PD ID 3726397 and 3729701 before pulling state mechanical permits.
  • Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
Homeowner ScenarioRecommended Verification Path
Best fit for HeilHomes matched to 23,200-46,500 BTU/h seeking R-454B compliance and verified ENERGY STAR documentation.
Skip or verify further ifExisting ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present.

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Heil Peak

Which Heil air-source heat pumps model reaches the highest 23.0 SEER2 rating?

H5H3V36*K*AAA* (EVD5X61M 3.0T) tops Heil's 50 ENERGY STAR air-source heat pumps models at 23.0 SEER2 across 23 AHRI matches (PD ID 3726397).

Lineup Span

How broad is Heil's air-source heat pumps efficiency and BTU range?

Heil spans 22.0 SEER2 (H5H3V48*K*AAA* (FCMA5B48 3.8T)) up to 23.0 SEER2 (H5H3V36*K*AAA* (EVD5X61M 3.0T)) across 23,200-46,500 BTU/h, compared with the 22.0 SEER2 category median.

AHRI Pairs

How many AHRI combinations support Heil air-source heat pumps?

Current ENERGY STAR datasets document 330 verified indoor-outdoor AHRI combinations distributed across 50 canonical Heil models.

Cold / Fuel

What refrigerants or fuels power Heil air-source heat pumps?

Heil air-source heat pumps listings record R-454B, with 50 Cold Climate certified models inside the air-source heat pumps cohort.

DOE Regions

Where are Heil air-source heat pumps compliant under 2026 federal rules?

Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.

CPSC Recalls

Are any CPSC safety recalls linked to Heil residential HVAC products?

ThermalSpec counts 0 residential HVAC CPSC filings referencing Heil; verify model serial prefixes at /recalls/ before installation or service.

25C Tax Credit

Do Heil air-source heat pumps receive federal Section 25C credits in 2026?

No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Heil in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 3726397.

Sizing Rule

How should homeowners select among Heil's 50 air-source heat pumps models?

Match Heil model capacity (23,200-46,500 BTU/h) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.

Sources

Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 6 pages.

Comparable HVAC Climate & Cost Metros