Carrier Air-Source Heat Pumps — ENERGY STAR Certified Models
Carrier certifies 36 air-source heat pumps models across 220 AHRI combinations, led by 27VNA336A*030* (CVAVA612 3.0T) at 23.0 SEER2 against the 22.0 SEER2 category median across 23,200-46,500 BTU/h. Carrier Air-Source Heat Pumps — ENERGY STAR Certified Models benchmarks residential systems using Certified Models set at 36 and Rating Span set at 22.0 SEER2 - 23.0 SEER2.
- Certified Models
- 36
- Rating Span
- 22.0 SEER2 - 23.0 SEER2
- Capacity Range
- 23,200-46,500 BTU/h
- AHRI Combinations
- 220
- Cold Climate Units
- 36
- Category Median
- 22.0 SEER2
How does Carrier's air-source heat pumps portfolio cover capacity, refrigerants, and safety?
Carrier covers 23,200-46,500 BTU/h in air-source heat pumps across 36 canonical models and 220 AHRI combinations, with 36 Cold Climate certified models and R-454B. Ratings span 22.0 SEER2 up to 23.0 SEER2 (category median 22.0 SEER2, certified through 2026-05-01). CPSC records show 4 residential HVAC recall notices matching Carrier; check exact AHRI matched pairings on individual model sheets.
Which verified records belong in Carrier Air-Source Heat Pumps — ENERGY STAR Certified Models?
Compare all 36 verified entries below. Click any column header to sort numerically or alphabetically, then select any row for full benchmark citations.
| Carrier 27VNA336A*030* (CVAVA612 3.0T) | 22.5 SEER2 | 9.0 HSPF2 | 35,800-36,000 | 23 |
| Carrier 27VNA336A*030* (CVAMA602 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | 20 |
| Carrier 27VNA336A*030* (CVAVA602 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600-35,800 | 20 |
| Carrier 27VNA324A*030* (CVAVA381 2.0T) | 23.0 SEER2 | 9.5 HSPF2 | 23,600-23,800 | 12 |
| Carrier 27VNA324A*030* (CVAMA321 2.0T) | 23.0 SEER2 | 9.5 HSPF2 | 23,600-23,800 | 11 |
| Carrier 27VNA324A*030* (CVAMA442 2.0T) | 23.0 SEER2 | 9.5 HSPF2 | 23,600-23,800 | 11 |
| Carrier 27VNA336A*030* (CVAMA442 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | 11 |
| Carrier 27VNA336A*030* (CVAMA492 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | 10 |
| Carrier 27VNA336A*030* (CVAMA612 3.0T) | 22.5 SEER2 | 8.5 HSPF2 | 35,800-36,000 | 9 |
| Carrier 27VNA336A*030* (CVAVA422 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | 9 |
| Carrier 27VNA324A*030* (CVAMA432 1.9T) | 22.5 SEER2 | 9.5 HSPF2 | 23,200-23,400 | 7 |
| Carrier 27VNA324A*030* (CVAVA372 1.9T) | 22.5 SEER2 | 9.5 HSPF2 | 23,200-23,400 | 7 |
| Carrier 27VNA324A*030* (CVAVA311 2.0T) | 22.5 SEER2 | 9.5 HSPF2 | 23,600 BTU/h | 6 |
| Carrier 27VNA324A*030* (CVAMA311 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,400 BTU/h | 6 |
| Carrier 27VNA336A*030* (CVAVA492 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | 6 |
| Carrier 27VNA324A*030* (CVAMA311 2.0T) | 22.5 SEER2 | 9.5 HSPF2 | 23,600 BTU/h | 5 |
| Carrier 27VNA324A*030* (CVAVA311 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,400 BTU/h | 5 |
| Carrier 27VNA324A*030* (CVAVA421 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,200-23,400 | 4 |
| Carrier 27VNA336A*030* (CVAVA492 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,400 BTU/h | 4 |
| Carrier 27VNA324A*030* (CVAMA251 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,000-23,200 | 3 |
| Carrier 27VNA324A*030* (CVAMA301 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,000-23,200 | 3 |
| Carrier 27VNA324A*030* (CVAMA361 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,000-23,200 | 3 |
| Carrier 27VNA324A*030* (CVAMA422 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,200 BTU/h | 3 |
| Carrier 27VNA324A*030* (CVAVA362 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,200 BTU/h | 3 |
| Carrier 27VNA324A*030* (CVAVA422 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,200 BTU/h | 3 |
| Carrier 27VNA324A*030* (CVAVA251 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,200 BTU/h | 2 |
| Carrier 27VNA324A*030* (CVAVA301 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,200 BTU/h | 2 |
| Carrier 27VNA324A*030* (CVAVA361 1.9T) | 22.0 SEER2 | 9.5 HSPF2 | 23,200 BTU/h | 2 |
| Carrier 27VNA336A*030* (CVAVA381 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,400 BTU/h | 2 |
| Carrier 27VNA336A*030* (CVAVA381 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,600 BTU/h | 2 |
| Carrier 27VNA348A*030* (FE5BNBD6 3.9T) | 23.0 SEER2 | 9.5 HSPF2 | 46,500 BTU/h | 1 |
| Carrier 27VNA336A*030* (CVAMA602 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,400 BTU/h | 1 |
| Carrier 27VNA336A*030* (CVAVA422 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,400 BTU/h | 1 |
| Carrier 27VNA336A*030* (CVAVA602 3.0T) | 22.0 SEER2 | 8.5 HSPF2 | 35,400 BTU/h | 1 |
| Carrier 27VNA336A*030* (FE5BNBD6 2.9T) | 22.0 SEER2 | 9.5 HSPF2 | 35,000 BTU/h | 1 |
| Carrier 27VNA348A*030* (FE5BN(B, 3.8T) | 22.0 SEER2 | 9.5 HSPF2 | 45,500 BTU/h | 1 |
Which top Carrier air-source heat pumps anchor this lineup?
Select any of the 4 verified listings below to open detailed specifications, safety boundaries, and source links.
Carrier 27VNA336A*030* (CVAVA612 3.0T)
Carrier 27VNA336A*030* (CVAMA602 3.0T)
Carrier 27VNA336A*030* (CVAVA602 3.0T)
Carrier 27VNA324A*030* (CVAVA381 2.0T)
What are the key limitations and who should not rely on this list alone?
Before booking an HVAC contractor or relying on Carrier Air-Source Heat Pumps, review 3 important real-world limits and verify local licensing and permit rules directly.
- Cohort spread across Carrier: 22.0 SEER2 entry units differ substantially from flagship 27VNA336A*030* (CVAVA612 3.0T) (23.0 SEER2).
- Verify indoor coil AHRI pairing on PD ID 3726394 and 3729699 before pulling state mechanical permits.
- Equipment catalog metrics exclude ductwork upgrades, A2L leak sensors where applicable, and municipal inspection fees.
| Homeowner Scenario | Recommended Verification Path |
|---|---|
| Best fit for Carrier | Homes matched to 23,200-46,500 BTU/h seeking R-454B compliance and verified ENERGY STAR documentation. |
| Skip or verify further if | Existing ductwork pushes total static pressure above 0.50 in. w.c. or 3-phase commercial wiring is present. |
Common questions homeowners ask
Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.
Which Carrier air-source heat pumps model reaches the highest 23.0 SEER2 rating?
27VNA336A*030* (CVAVA612 3.0T) tops Carrier's 36 ENERGY STAR air-source heat pumps models at 23.0 SEER2 across 23 AHRI matches (PD ID 3726394).
How broad is Carrier's air-source heat pumps efficiency and BTU range?
Carrier spans 22.0 SEER2 (27VNA348A*030* (FE5BN(B, 3.8T)) up to 23.0 SEER2 (27VNA336A*030* (CVAVA612 3.0T)) across 23,200-46,500 BTU/h, compared with the 22.0 SEER2 category median.
How many AHRI combinations support Carrier air-source heat pumps?
Current ENERGY STAR datasets document 220 verified indoor-outdoor AHRI combinations distributed across 36 canonical Carrier models.
What refrigerants or fuels power Carrier air-source heat pumps?
Carrier air-source heat pumps listings record R-454B, with 36 Cold Climate certified models inside the air-source heat pumps cohort.
Where are Carrier air-source heat pumps compliant under 2026 federal rules?
Models meeting 13.4 SEER2 qualify in the North; 14.3 SEER2 (plus 11.7 EER2 or 9.8 at 15.2+ SEER2) is needed for Southwest split cooling, while split heat pumps require 14.3 SEER2 / 7.5 HSPF2 nationwide.
Are any CPSC safety recalls linked to Carrier residential HVAC products?
ThermalSpec counts 4 residential HVAC CPSC filings referencing Carrier; verify model serial prefixes at /recalls/ before installation or service.
Do Carrier air-source heat pumps receive federal Section 25C credits in 2026?
No — IRS Section 25C credits terminated December 31, 2025 ($0 federal tax credit for Carrier in 2026). Check state HOMES/HEAR and local utility ENERGY STAR rebates using PD ID 3726394.
How should homeowners select among Carrier's 36 air-source heat pumps models?
Match Carrier model capacity (23,200-46,500 BTU/h) using an ACCA Manual J room-by-room heat load and <= 0.50 in. w.c. static pressure check rather than old unit tonnage.
Sources
Verified numerical figures and rules trace to the 4 cited federal, state, or OEM documents listed below.
- ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
- 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C Termination Dec 31, 2025) — Internal Revenue Service (IRS), Public Law 119-21 (OBBBA) (retrieved 2026-11-23)