Skip to main content
Air-Source Heat Pump · Carrier · 4 ENERGY STAR Combinations

Carrier 27VNA324A*030* (CVAVA421 1.9T) — Air-Source Heat Pump Specifications

Carrier 27VNA324A*030* (CVAVA421 1.9T) (Air-Source Heat Pump, PD ID 4499916) holds 4 ENERGY STAR certified SKUs rated at 22.0 SEER2 — #147 of 586 (407 tied at median), Equal to 22.0 SEER2 category median. Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2).

Max SEER2
22.0 SEER2
Heating Rating
9.5 HSPF2
Heating COP
2.08 COP
Cohort Rank
#147/586
Verified Combos
4 SKUs
Sample PD ID
4499916
Air-Source Heat Pump Efficiency Spread across 586 certified series (21.5 to 25.0 SEER2)
Carrier 27VNA324A*030* (CVAVA421 1.9T) Air-Source Heat Pump Efficiency Spread Distribution Distribution of 586 certified series from 21.5 to 25.0 SEER2. Carrier 27VNA324A*030* (CVAVA421 1.9T) sits at 22.0 SEER2; typical midpoint is 22.0 SEER2. 33 21.5 407 21.9 88 22.3 54 22.7 1 23.1 0 23.4 2 23.8 0 24.2 1 24.6 Median 22.0 SEER2 This model: 22.0 SEER2 (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
21.5 - 21.9 SEER233Peer range
21.9 - 22.3 SEER2407This series
22.3 - 22.7 SEER288Peer range
22.7 - 23.1 SEER254Peer range
23.1 - 23.4 SEER21Peer range
23.4 - 23.8 SEER20Peer range
23.8 - 24.2 SEER22Peer range
24.2 - 24.6 SEER20Peer range
24.6 - 25.0 SEER21Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Carrier 27VNA324A*030* (CVAVA421 1.9T) residential equipment inspection. ThermalSpec Editorial Photography

How does Carrier 27VNA324A*030* (CVAVA421 1.9T) rank across federal compliance and ENERGY STAR cohorts?

Carrier 27VNA324A*030* (CVAVA421 1.9T) ranks #147 of 586 (tied with 406 others at 22.0 SEER2, more efficient than 5.6% of certified series) for Max SEER2 (Equal to 22.0 SEER2 category median) across 4 certified SKU combinations. Rated for cold-climate output (81.2% capacity retention at 5F) (1.9 nominal Tons at 23,400 BTU/h) charged with R-454B. Cleared for North, Southeast, and Southwest (AZ/CA/NM/NV) peak-EER2 installations.

Carrier 27VNA324A*030* (CVAVA421 1.9T) Cohort Metrics vs. Air-Source Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max SEER2) #147 of 586 (407 tied at median) Equal to 22.0 SEER2 category median
Heating HSPF2 vs Cohort 9.5 HSPF2 +0.50 HSPF2 vs 9.0 HSPF2 median
Peak 95F EER2 vs Cohort 13.5 EER2 +1.00 EER2 vs 12.5 EER2 median
5F Cold-Weather Capacity Retention 81.2% of 47F rating 5F COP 2.08
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
Federal North & SE Heat Pump Minimum PASS Requires >=14.3 SEER2 & >=7.5 HSPF2; unit reaches 22.0 SEER2 / 9.5 HSPF2
Southwest Peak-Heat Criterion (AZ/CA/NM/NV) PASS Requires 11.7 EER2 (or 9.8 if >=15.2 SEER2); unit max 13.5 EER2
ENERGY STAR Cold Climate Spec CERTIFIED Cold Climate verified (580/586 series in category)
2026 Cleaner Refrigerant Rule R-454B / R-32 READY Listed refrigerant: R-454B; newer R-454B/R-32 splits include indoor leak sensors

How much annual energy and operating cost does Carrier 27VNA324A*030* (CVAVA421 1.9T) require?

Annual cost outputs combine Carrier 27VNA324A*030* (CVAVA421 1.9T)'s 22.0 SEER2 rating and EIA national tariffs across single-family runtime hours.

Cool_kWh = (23,400 BTU/h * 1,000 hrs / 22.0 SEER2) / 1,000 | Heat_kWh = 30,000 kBTU / 9.5 HSPF2

Assumes 1,000 cooling hrs + 30 MMBtu heating at US 51-state median 16.33 c/kWh (range 12.72 c NV to 47.18 c HI)

Operating BasisEstimated ValueSource Basis
Estimated Annual Cooling Energy1,064 kWh/yr$174/yr at US median
Estimated Annual Heating Energy (30 MMBtu)3,158 kWh/yr$516/yr at US median
Combined Annual Electricity Cost$689/yrState range: $537 (NV) to $1,992 (HI)
Annual Savings vs 14.3 SEER2 / 7.5 HSPF2 Floor1,414 kWh/yr$231/yr saved
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Carrier 27VNA324A*030* (CVAVA421 1.9T)?

Showing 4 certified indoor-outdoor coil combinations from 4 total AHRI matched records filed for Carrier 27VNA324A*030* (CVAVA421 1.9T) (PD ID 4499916).

27VNA324A*030* CVAVA4217XMA*+UI 23,200 BTU/h 22.0 SEER2 / 9.5 HSPF2
27VNA324A*030* CVAVA4217XMA*+UI 23,200 BTU/h 22.0 SEER2 / 9.5 HSPF2
27VNA324A*030* CVAVA4217XMA*+UI 23,200 BTU/h 22.0 SEER2 / 9.5 HSPF2
27VNA324A*030* CVAVA4217XMA*+UI 23,400 BTU/h 22.0 SEER2 / 9.5 HSPF2

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Carrier 27VNA324A*030* (CVAVA421 1.9T), review 3 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Carrier 27VNA324A*030* (CVAVA421 1.9T): headline Max SEER2 reflects peak tested matches among 4 SKUs, not lower-rated sizes.
  • Catalog specs for Carrier 27VNA324A*030* (CVAVA421 1.9T) exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
  • Carrier 27VNA324A*030* (CVAVA421 1.9T) uses A2L R-454B, needing UL 60335-2-40 RDS coil mitigation wiring above threshold charge.
Homeowner ScenarioRecommended Verification Path
Ideal Carrier 27VNA324A*030* (CVAVA421 1.9T) fitSingle-family replacement needing documented ENERGY STAR PD ID 4499916 with matching indoor air handler.
Skip Carrier 27VNA324A*030* (CVAVA421 1.9T) ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable air-source heat pump models deliver similar efficiency?

Compare Carrier 27VNA324A*030* (CVAVA421 1.9T) against ACIQ B5H3V24*K*AAA* (EVD5X31M 1.9T) and closely matched air-source heat pump units sharing similar Max SEER2 output and BTU tonnage.

ACIQ B5H3V24*K*AAA* (EVD5X31M 1.9T)

22.0 SEER2 · 9.5 HSPF2 · 23,400 BTU/h

ACIQ B5H3V24*K*AAA* (EVD5X42M 1.9T)

22.0 SEER2 · 9.5 HSPF2 · 23,400 BTU/h

ACIQ B5H3V24*K*AAA* (EVM5X31M 1.9T)

22.0 SEER2 · 9.5 HSPF2 · 23,400 BTU/h

Airquest B5H3V24*K*AAA* (EVD5X31M 1.9T)

22.0 SEER2 · 9.5 HSPF2 · 23,400 BTU/h

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Carrier 27VNA324A*030* (CVAVA421 1.9T) compare with peer Air-Source Heat Pump units?

Carrier 27VNA324A*030* (CVAVA421 1.9T) holds #147 of 586 (407 tied at median) out of 586 verified air-source heat pump models (Equal to 22.0 SEER2 category median), spanning 4 certified SKUs up to 22.0 SEER2. Closest same-cohort alternatives include ACIQ B5H3V24*K*AAA* (EVD5X31M 1.9T).

DOE Regions

Where is Carrier 27VNA324A*030* (CVAVA421 1.9T) compliant for 2026 US installation?

Carrier 27VNA324A*030* (CVAVA421 1.9T): Meets US North, Southeast & Southwest 10 CFR 430.32 split heat pump minimums (14.3 SEER2 / 7.5 HSPF2). In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Carrier 27VNA324A*030* (CVAVA421 1.9T) model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Carrier 27VNA324A*030* (CVAVA421 1.9T) runs 1,064 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Carrier 27VNA324A*030* (CVAVA421 1.9T) cover?

Carrier 27VNA324A*030* (CVAVA421 1.9T) covers 23,200-23,400 BTU/h around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Carrier 27VNA324A*030* (CVAVA421 1.9T) handle extreme weather or cold snaps?

Yes, Carrier 27VNA324A*030* (CVAVA421 1.9T) carries ENERGY STAR Cold Climate certification (81.2% capacity retention at 5 F).

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Carrier 27VNA324A*030* (CVAVA421 1.9T)?

Carrier 27VNA324A*030* (CVAVA421 1.9T) specifies R-454B compliance (PD ID 4499916); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 4 certified SKUs in Carrier 27VNA324A*030* (CVAVA421 1.9T) reach 22.0 SEER2?

Peak 22.0 SEER2 represents the top tested AHRI pairing for Carrier 27VNA324A*030* (CVAVA421 1.9T) (PD ID 4499916); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Carrier 27VNA324A*030* (CVAVA421 1.9T)?

Carrier 27VNA324A*030* (CVAVA421 1.9T) requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include ACIQ B5H3V24*K*AAA* (EVD5X31M 1.9T).

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Air-Source Heat Pumps Dataset (w7cv-9xjt) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros