Skip to main content
Geothermal Heat Pump · Nordic · 1 ENERGY STAR Combinations

Nordic TF75HACW-P-1T-*-SDE** — Geothermal Heat Pump Specifications

Nordic TF75HACW-P-1T-*-SDE** (Geothermal Heat Pump, PD ID 2667777) holds 1 ENERGY STAR certified SKU rated at 4.2 COP — #1,368 of 1,730 (135 tied, beats 13.2% of peers), -0.30 COP. ENERGY STAR certified residential HVAC model. Nordic TF75HACW-P-1T-*-SDE** — Geothermal Heat Pump Specifications benchmarks residential systems using Heating COP set at 4.2 COP and Cohort Rank set at #1,368/1,730.

Heating COP
4.2 COP
Cohort Rank
#1,368/1,730
Verified Combos
1 SKU
Sample PD ID
2667777
Geothermal Heat Pump Efficiency Spread across 1730 certified series (3.9 to 5.7 COP)
Nordic TF75HACW-P-1T-*-SDE** Geothermal Heat Pump Efficiency Spread Distribution Distribution of 1730 certified series from 3.9 to 5.7 COP. Nordic TF75HACW-P-1T-*-SDE** sits at 4.2 COP; typical midpoint is 4.5 COP. 228 3.9 329 4.1 251 4.3 296 4.5 244 4.7 310 4.9 37 5.1 32 5.3 3 5.5 Median 4.5 COP This model: 4.2 COP (Higher is better)
Inspect chart data table (9 rows)
Efficiency BandSeries CountPosition
3.9 - 4.1 COP228Peer range
4.1 - 4.3 COP329This series
4.3 - 4.5 COP251Peer range
4.5 - 4.7 COP296Peer range
4.7 - 4.9 COP244Peer range
4.9 - 5.1 COP310Peer range
5.1 - 5.3 COP37Peer range
5.3 - 5.5 COP32Peer range
5.5 - 5.7 COP3Peer range
Residential copper-tube evaporator A-coil with refrigerant leak detection sensor probe
Nordic TF75HACW-P-1T-*-SDE** residential equipment inspection. ThermalSpec Editorial Photography

How does Nordic TF75HACW-P-1T-*-SDE** rank across federal compliance and ENERGY STAR cohorts?

Nordic TF75HACW-P-1T-*-SDE** ranks #1,368 of 1,730 (tied with 134 others at 4.20 COP, more efficient than 13.2% of certified series) for Max COP (-0.30 COP vs 4.50 COP category median) across 1 certified SKU combination. Open Loop Water-to-Air unit delivering 4.2 COP and 21.2 EER across closed- or open-loop residential piping. Zero CPSC residential HVAC recall filings match Nordic in ThermalSpec's current SaferProducts feed.

Nordic TF75HACW-P-1T-*-SDE** Cohort Metrics vs. Geothermal Heat Pump Peers
Cohort Benchmark Series Metric Dataset Context
Category Rank (Max COP) #1,368 of 1,730 (135 tied, beats 13.2% of peers) -0.30 COP vs 4.50 COP category median
Closed/Open Loop EER vs Cohort 21.2 EER -3.40 EER vs 24.6 EER median
Federal Efficiency & Cold-Climate Readiness Checks
Compliance RuleStatusEngineering Criterion
ENERGY STAR Most Efficient Criteria MOST EFFICIENT Max COP 4.2 / Max EER 21.2 (Open Loop Water-to-Air)
EPA AIM Act Refrigerant Transition VERIFY OEM SPEC Dataset refrigerant: R-410A

How much annual energy and operating cost does Nordic TF75HACW-P-1T-*-SDE** require?

Using 16.33 c/kWh electricity and $1.45/therm gas benchmarks, Nordic TF75HACW-P-1T-*-SDE** estimates reflect 1 certified SKU combination tested under PD ID 2667777.

Heat_kWh = 50,000 kBTU / (4.2 COP * 3.412) | Cool_kWh = 36,000 BTU * 1,000 hrs / (21.2 EER * 1,000)

50 MMBtu heating + 36k BTU cooling at US median 16.33 c/kWh

Operating BasisEstimated ValueSource Basis
Ground-Source Heating Electricity3,489 kWh/yr$570/yr
Ground-Source Cooling Electricity (1,000 hrs)1,698 kWh/yr$277/yr
Total Annual Geothermal Operating Cost$847/yrState range: $660 to $2,447
UL 60335-2-40 A2L Leak Detection (RDS) & Dilution Airflow
A2L Refrigerant Detection System Mitigation Schematic Air handler plenum showing Evaporator Coil, RDS sensor near drain pan, lockout signal to compressor, and forced blower dilution into conditioned space. Air Handler Plenum Evaporator Coil A2L RDS SENSOR FAN Mitigation Control 1. Compressor OFF 2. Electric Heat OFF 3. Blower FORCED ON Conditioned Zone R-454B GWP: 466 LFL: 0.296 kg/m3 R-32 GWP: 675 LFL: 0.307 kg/m3 Diluted < 25% LFL

When R-454B or R-32 leaks above charge thresholds, the RDS sensor shuts off the compressor and runs the indoor fan continuously to dilute the air.

Which AHRI certified SKU combinations belong to Nordic TF75HACW-P-1T-*-SDE**?

Showing 1 certified indoor-outdoor coil combinations from 1 total AHRI matched records filed for Nordic TF75HACW-P-1T-*-SDE** (PD ID 2667777).

TF75HACW-P-1T-*-SDE** Matched AHRI Coil —

What are the key limitations and who should not rely on this list alone?

Before booking an HVAC contractor or relying on Nordic TF75HACW-P-1T-*-SDE**, review 2 important real-world limits and verify local licensing and permit rules directly.

  • Coil pairing spread across Nordic TF75HACW-P-1T-*-SDE**: headline Max COP reflects peak tested matches among 1 SKU, not lower-rated sizes.
  • Catalog specs for Nordic TF75HACW-P-1T-*-SDE** exclude ductwork sealing, 240V breaker upgrades, condensate drainage, and local mechanical permit fees.
Homeowner ScenarioRecommended Verification Path
Ideal Nordic TF75HACW-P-1T-*-SDE** fitSingle-family replacement needing documented ENERGY STAR PD ID 2667777 with matching indoor air handler.
Skip Nordic TF75HACW-P-1T-*-SDE** ifManual J load calculations remain undone, ducts leak excessively, or commercial 3-phase power is installed.

Which comparable geothermal heat pump models deliver similar efficiency?

Compare Nordic TF75HACW-P-1T-*-SDE** against Enertech EBT072* and closely matched geothermal heat pump units sharing similar Max COP output and BTU tonnage.

Enertech EBT072*

4.2 COP · 22.5 EER · 1 combos

Enertech EWS048*

4.2 COP · 22.9 EER · 1 combos

Enertech EZT072*

4.2 COP · 22.0 EER · 1 combos

GEO-THERMAL SPLIT GZ072SA*C******1

4.2 COP · 23.3 EER · 2 combos

Common questions homeowners ask

Read these 8 clear, fact-checked answers on efficiency rules, safety limits, and typical costs before booking service.

Cohort Rank

How does Nordic TF75HACW-P-1T-*-SDE** compare with peer Geothermal Heat Pump units?

Nordic TF75HACW-P-1T-*-SDE** holds #1,368 of 1,730 (135 tied, beats 13.2% of peers) out of 1,730 verified geothermal heat pump models (-0.30 COP vs 4.50 COP category median), spanning 1 certified SKU up to 4.2 COP. Closest same-cohort alternatives include Enertech EBT072*.

DOE Regions

Where is Nordic TF75HACW-P-1T-*-SDE** compliant for 2026 US installation?

Nordic TF75HACW-P-1T-*-SDE**: ENERGY STAR certified residential HVAC model. In AZ, CA, NM, and NV, split AC pairings under 45,000 BTU/h must also pass 11.7 EER2 or 9.8 EER2 at 15.2+ SEER2.

Annual Energy

What annual operating cost does Nordic TF75HACW-P-1T-*-SDE** model at US tariffs?

At 16.33 c/kWh electricity and $1.45/therm gas, Nordic TF75HACW-P-1T-*-SDE** runs 3,489 kWh/yr across standard cooling/heating hours.

BTU & Airflow

What capacity band and airflow does Nordic TF75HACW-P-1T-*-SDE** cover?

Nordic TF75HACW-P-1T-*-SDE** covers varies by coil match around 400 CFM/ton airflow, requiring room-level Manual J load verification and static pressure <= 0.50 in. w.c.

Cold Climate / Suit

How does Nordic TF75HACW-P-1T-*-SDE** handle extreme weather or cold snaps?

Nordic TF75HACW-P-1T-*-SDE** is a standard-climate unit best suited above sub-zero winter design temps unless paired with electric or gas backup heat.

2026 Credits & Ref

What refrigerant class and 2026 tax credit rules govern Nordic TF75HACW-P-1T-*-SDE**?

Nordic TF75HACW-P-1T-*-SDE** specifies R-410A compliance (PD ID 2667777); federal 25C tax credits expired Dec 31, 2025 ($0 federal credit in 2026), leaving state utility rebates.

Coil Matching

Do all 1 certified SKU in Nordic TF75HACW-P-1T-*-SDE** reach 4.2 COP?

Peak 4.2 COP represents the top tested AHRI pairing for Nordic TF75HACW-P-1T-*-SDE** (PD ID 2667777); exact tonnage and indoor coil selections vary final EER2/HSPF2.

Safety & Install

What licensing and safety checks apply to Nordic TF75HACW-P-1T-*-SDE**?

Nordic TF75HACW-P-1T-*-SDE** requires EPA Section 608 certification for refrigerant work, state mechanical licensing, and UL 60335-2-40 compliance where applicable. Closest same-cohort alternatives include Enertech EBT072*.

Sources

Verified numerical figures and rules trace to the 6 cited federal, state, or OEM documents listed below.

  1. ENERGY STAR Certified Geothermal Heat Pumps Dataset (acvd-5wvz) — U.S. EPA ENERGY STAR, Socrata Open Data 2026 (retrieved 2026-11-23)
  2. 10 CFR 430.32 Energy and Water Conservation Standards (SEER2, EER2, HSPF2, AFUE) — U.S. Department of Energy / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  3. 40 CFR Part 82 Subpart F — Recycling and Emissions Reduction (EPA Section 608) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  4. 40 CFR Part 84 — Phasedown of Hydrofluorocarbons (Sec. 84.54 Technology Transitions) — U.S. EPA / eCFR, eCFR 2026-11-19 (retrieved 2026-11-23)
  5. UL 60335-2-40 A2L Refrigerant Detection & EIA-456-A Run Capacitor Tolerance — UL Solutions / ECIA, 4th Edition UL 60335-2-40 (retrieved 2026-11-23)
  6. Electric Power Monthly Table 5.6.A — Average Price of Electricity to Residential Customers by State — U.S. Energy Information Administration (EIA), EIA Electric Power Monthly 2026 (retrieved 2026-11-23)

Related Pages

Explore nearby state efficiency rules, certified equipment models, and homeowner cost calculators across these 9 pages.

Comparable HVAC Climate & Cost Metros